TL* THE CONTACT OWNS A 1993 FORD F-250 EQUIPPED WITH COOPER DEAN MUD TERRAIN RADIAL SXT TIRES, SIZE 285/75/16. THE CONTACT STATED THAT THERE WERE BLISTERS BETWEEN THE LUGS. THE FRONT PASSENGER TIRE HAD WIRES PROTRUDING, WHICH WAS CAUSING TREAD SEPARATION. THE MANUFACTURER ADVISED THE CONTACT THAT THE TIRES WERE NOT INCLUDED IN…
Read full complaint
TL* THE CONTACT OWNS A 1993 FORD F-250 EQUIPPED WITH COOPER DEAN MUD TERRAIN RADIAL SXT TIRES, SIZE 285/75/16. THE CONTACT STATED THAT THERE WERE BLISTERS BETWEEN THE LUGS. THE FRONT PASSENGER TIRE HAD WIRES PROTRUDING, WHICH WAS CAUSING TREAD SEPARATION. THE MANUFACTURER ADVISED THE CONTACT THAT THE TIRES WERE NOT INCLUDED IN NHTSA RECALL NUMBER: 06T003000(TIRES:TREAD/BELT). THE CURRENT AND FAILURE MILEAGES WERE 234,242.
NHTSA ODI #10428688
Mileage unknown · Jun 5, 2008
Tires
TIRE WENT FLAT FOR NO REASON ONLY HAD 2000 MILES ON THEM NOW THEY SAY THEY DON'T MAKE THEM ANYMORE SO I CANT GET ONE TO MATCH CAN NOT DRIVE FORD F 250 TILL I FIND ONE. TIRE WAS A DAYTON A BAJA A/T WIDETRACK 33/1250/16.5 *TR
NHTSA ODI #10229997
Mileage unknown · Dec 3, 2000
Tires
IN THE WAY OF AN INTRODUCTION, AND TO HELP EXPLAIN THE TECHNICAL DETAIL IN THE FOLLOWING DESCRIPTION, I THINK IT IS WORTHWHILE TO EXPLAIN THAT I AM A RETIRED RESEARCH AND TEST ENGINEER WHO SPENT 22 YEARS OF MY PROFESSIONAL CAREER AS AN ENGINEER WORKING FOR PACCAR INC, THEY MANUFACTURE KENWORTH AND PETERBILT TRUCKS. THE VAST MAJ…
Read full complaint
IN THE WAY OF AN INTRODUCTION, AND TO HELP EXPLAIN THE TECHNICAL DETAIL IN THE FOLLOWING DESCRIPTION, I THINK IT IS WORTHWHILE TO EXPLAIN THAT I AM A RETIRED RESEARCH AND TEST ENGINEER WHO SPENT 22 YEARS OF MY PROFESSIONAL CAREER AS AN ENGINEER WORKING FOR PACCAR INC, THEY MANUFACTURE KENWORTH AND PETERBILT TRUCKS. THE VAST MAJORITY OF MY TIME WITH PACCAR WAS SPENT TESTING AUTOMOTIVE PRODUCTS AT THEIR TRUCK R&D CENTER. ( DOT NUMBER: PJOR D6KV TIRE SIZE: LT235/85R1 )
NHTSA ODI #737244
Mileage unknown · Sep 30, 2000
Tires
FRONT TIRE BLEW OUT (TREAD SEPARATED) AT 70 MPH, LOST CONTROL, DID NOT WRECK, MINOR DAMAGE TO VEHICLE FENDER. I HAVE PICTURES OF THE TIRE IF YOU WOULD LIKE TO HAVE THEM. I HAVE REMOVED THE MATE TO THIS TIRE BECAUSE THE SCARE I HAD. *AK (DOT NUMBER: VDOR65B187 TIRESIZE: 23585R16 M)
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Consequence & remedy
Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.
Consequence & remedy
Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.
Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.
Consequence & remedy
Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.
Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
3
EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
EA95012 · Failure Of Serpentine Belt
Opened Mar 31, 1995 · Closed May 28, 1996
Status: closed (inferred from source dates) · Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
Additional source detail variants (2)
Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
EA93020 · Parking Brake Failure
Opened Jul 28, 1993 · Closed Sep 23, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
Additional source detail variants (2)
Service Brakes, Hydraulic
There is no summary currently available
Service Brakes, Hydraulic
There is no summary currently available
1993 Ford F-250 Problems, Complaints & Recalls | Skip That Year