FUEL LEAKED FROM HEATER WIRE IN FUEL FILTER. THE FUEL FOLLOWED THE WIRE UP THE COPPER CORE UNTIL IT REACHED A CRACK IN THE INSULATION ANY TIME THERE WAS FUEL PRESSURE, IE ENGINE RUNNING OR EVEN WITH BOOST PUMP PRESSURE WITH ENGINE OFF.
1991 Ford F-250
Owner reports · Recalls · Investigations
Similar to other model years
Owner complaints for the 1991 Ford F-250 do not stand out strongly from the model-year median of 119.
About this comparison →How this year compares
Owner complaints by model year
Compare all F-250 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 15 of 107 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 26 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Service Brakes, Hydraulic. Review the 24 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
107 reportsTL* THE CONTACT OWNS A 1991 FORD F-250. AFTER THE VEHICLE WAS PARKED, THE CONTACT NOTICED A STRONG FUEL ODOR FROM THE SIDE OF THE VEHICLE. THE CONTACT NOTICED FUEL POURING OUT OF THE OPENING OF THE TANK THAT SPILLED ONTO THE STREET AND UNDERNEATH ANOTHER VEHICLE. THE DEALER STATED THAT THE FUEL CHECK VALVE IN THE PUMP UNIT WAS D…
Read full complaint
TL* THE CONTACT OWNS A 1991 FORD F-250. AFTER THE VEHICLE WAS PARKED, THE CONTACT NOTICED A STRONG FUEL ODOR FROM THE SIDE OF THE VEHICLE. THE CONTACT NOTICED FUEL POURING OUT OF THE OPENING OF THE TANK THAT SPILLED ONTO THE STREET AND UNDERNEATH ANOTHER VEHICLE. THE DEALER STATED THAT THE FUEL CHECK VALVE IN THE PUMP UNIT WAS DAMAGED, WHICH CAUSED THE FUEL TO TRAVEL FROM ONE TANK TO THE OTHER AND OVERFLOW. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT INFORMED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 137,000.
TL* THE CONTACT OWNS A 1991 FORD F-250. AFTER REFUELING THE VEHICLE, FUEL STARTED LEAKING FROM THE FUEL TANK. THE VEHICLE WAS NOT DIAGNOSED OR REPAIRED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE CONTACT WAS AWARE OF NHTSA CAMPAIGN NUMBER: 01I008000 (FUEL SYSTEM, GASOLINE) BUT THE VIN WAS NOT INCLUDED. THE FAILURE MIL…
Read full complaint
TL* THE CONTACT OWNS A 1991 FORD F-250. AFTER REFUELING THE VEHICLE, FUEL STARTED LEAKING FROM THE FUEL TANK. THE VEHICLE WAS NOT DIAGNOSED OR REPAIRED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE CONTACT WAS AWARE OF NHTSA CAMPAIGN NUMBER: 01I008000 (FUEL SYSTEM, GASOLINE) BUT THE VIN WAS NOT INCLUDED. THE FAILURE MILEAGE WAS 161,000. ..UPDATED 05/20/15 *BF THE CONSUMER HAS EXPERIENCED THE FUEL SWITCH OVER ISSUE AND WOULD LIKE TO BE ADDED TO THE RECALL. UPDATED 7/6/2015 *JS
I HAD JUST BEEN JUMPED BY AAA BECAUSE MY TRUCK WASN'T STARTING; THE AAA AGENT ALSO CLEANED THE BATTERY TERMINALS. I INTENDED TO HAVE IT TOWED TO THE FORD DEALER BECAUSE I DIDN'T THINK IT WOULD START. SINCE THE AAA AGENT WAS ABLE TO GET TO START, I DECIDED TO STILL TAKE IT TO THE DEALER TO FIND OUT WHY THE BATTERY WAS DEAD (GIV…
Read full complaint
I HAD JUST BEEN JUMPED BY AAA BECAUSE MY TRUCK WASN'T STARTING; THE AAA AGENT ALSO CLEANED THE BATTERY TERMINALS. I INTENDED TO HAVE IT TOWED TO THE FORD DEALER BECAUSE I DIDN'T THINK IT WOULD START. SINCE THE AAA AGENT WAS ABLE TO GET TO START, I DECIDED TO STILL TAKE IT TO THE DEALER TO FIND OUT WHY THE BATTERY WAS DEAD (GIVEN THEY HAD THE CAR FOR A MONTH AND HAD PUT IN A NEW BATTERY AND STARTER, AMONG OTHER REPAIRS). DRIVING THE 7 MILES TO THE DEALERSHIP THE CAR SEEMED TO BE ACCELERATING ON ITS OWN, THE ENTIRE WAY, I ONLY STEPPED ON THE GAS ONCE; IT WAS GOING 35 MILES/HOUR BY ITSELF (PER THE SPEEDOMETER). I DIDN'T KNOW WHY THIS WAS HAPPENING AND WHEN I TRIED TO SLOW DOWN USING THE BRAKES, THE TRUCK WAS VERY DIFFICULT TO STOP, SUCH THAT I NEARLY REAR-ENDED MULTIPLE CARS. IT WAS ALL I COULD DO TO PUSH THE BRAKE DOWN AND TWICE HUGE AMOUNTS OF SMOKE CAME FROM UNDER THE VEHICLE (PROBABLY THE BRAKES WERE NOW OVERHEATING?). WHEN I WAS 500 FEET FROM THE DEALERSHIP I TOOK A QUICK LEFT TURN AND HONESTLY COULD NOT STOP THE TRUCK, I THREW IT INTO PARK AND SHUT IT OFF JUST IN TIME TO MISS PLOWING INTO PARKED VEHICLES. SMOKE BILLOWED OUT FROM BELOW THE HOOD. I HAVE NEVER BEEN SO FRIGHTENED IN MY LIFE-I WAS SURE I WAS EITHER GOING TO SMASH INTO SOMEONE SINCE I COULDN'T STOP OR THE TRUCK WAS GOING TO IMPLODE IN FIRE, OR SOMETHING AND I WOULD BE DEAD. I WAS NOT ABLE TO SUCCESSFULLY STOP IT USING THE BRAKES. THE PARKING BRAKE WAS ALSO NOT WORKING (WHICH IS ALSO WHY I WAS RETURNING IT TO THE DEALER). WHEN I ASKED THE SERVICE PERSON AT THE FORD DEALERSHIP IF HE'D SEEN A STUCK THROTTLE LIKE THIS BEFORE, HE SAID, "YES, SOMETIMES WHEN VEHICLES SIT FOR A WHILE". THIS IS A SATURDAY, SO THEY ARE GOING TO EVALUATE THE PROBLEM ON MONDAY. THE SERVICE REP ALSO SAID SOMETIMES CLEANING THE TERMINALS MIGHT CONTRIBUTE TO EXTRA CONDUCTION, WHICH MIGHT HAVE CAUSED THE ACCELERATION ISSUE. *TR
THE VEHICLE IS A 1990 AND THE SITE DOES NOT PROVIDE A SPACE CHOICE FOR THE 1990, ONLY '91 AND UP. THE TRUCK HAS THE EXACT SAME PROBLEM AS THE OTHER MANY FORD TRUCKS. WHILE IDLING, OR UNDERWAY, THE VEHICLE SPEWS GASOLINE FROM THE FRONT TANK, OUT ONTO THE ROAD, OR ANY DRIVEWAY, IF IDLING. IT'S CLEAR THAT ONCE YOU FILL THE REAR T…
Read full complaint
THE VEHICLE IS A 1990 AND THE SITE DOES NOT PROVIDE A SPACE CHOICE FOR THE 1990, ONLY '91 AND UP. THE TRUCK HAS THE EXACT SAME PROBLEM AS THE OTHER MANY FORD TRUCKS. WHILE IDLING, OR UNDERWAY, THE VEHICLE SPEWS GASOLINE FROM THE FRONT TANK, OUT ONTO THE ROAD, OR ANY DRIVEWAY, IF IDLING. IT'S CLEAR THAT ONCE YOU FILL THE REAR TANK AND THEN TRAVEL, THE FUEL, WHICH SHOULD RETURN TO THE REAR TANK IN A CYCLE, DOES NOT. IT SIMPLY RETURNS TO THE FRONT TANK, UNTIL IT FILLS THE FRONT TANK AND FLOODS OUT. THE PUMP IN THE REAR TANK APPEARS TO JUST CONTINUE TO RUN, FOR EXAMPLE,,,, YOU HAVE A FULL REAR TANK. YOU HAVE HALF A TANK OF FUEL IN THE FRONT TANK. YOU DRIVE. THE REAR TANK PUMP, PUMPS ALL OF THE FULL REAR TANK INTO THE FRONT TANK. SO, HALF A TANK OF GAS FLOWS OUT OF THE FRONT TANK, ONTO THE GROUND. OBVIOUSLY, THE CYCLE, WHERE THE FUEL SHOULD GO FROM REAR, TO ENGINE AND BACK, ISN'T HAPPENING. INSTEAD, THE FUEL ROLLS BY THE ENGINE AND RETURNS TO A FULL FRONT TANK, RATHER THAN THE REAR TANK, SO, ONTO THE GROUND GOES THE FUEL. ON AN OLDER RECALL REPORT, THE REPAIR IS DESCRIBED, WHERE THE 'JUMPER' MUST BE REPLACED, DESPITE THE FACT THERE'S NO SUCH THING, THERE'S A FUEL PUMP AND PROBABLY SOME SORT OF 'BI-VALVE' THAT SOMEONE'S POOR ENGINEERING FAILED ON THE WHOLE, AT THE TIME OF DESIGN. I THINK I'LL JUST PULL INTO THE LOCAL FORD LOT AND IDLE OUT A FEW GALLONS NOW AND THEN. BUT SINCE THE 90 ISN'T ON THE RECALL, DESPITE THE OBVIOUS EXACT PROBLEM AS THE 91'S AND UP, THERE'S NO USE. IT WOULD SEEM COMMON SENSE, THAT DEALERS COULD SIMPLY BE NOTIFIED THAT THE 1990 F 250'S ARE DOING THE EXACT THING AS MANY OTHER MAKES AND THE LEAST THE DEALER COULD DO, IS BE A LITTLE MORE SPECIFIC ABOUT THE REPAIR. BUT NOT IF THEIR CORPORATE ENGINEERS AND REPAIR CENTERS KEEP THE MECHANICAL INFORMATION SECRET, OR WRITTEN IN SOME MANUFACTURER 'CODE LANGUAGE'. *TR
TL* THE CONTACT OWNS A 1991 FORD F250. THE CONTACT STATED THAT GASOLINE FUEL WAS LEAKING FROM THE VEHICLE AND ONTO THE DRIVEWAY. THE VEHICLE WAS NOT TAKEN TO THE DEALER FOR INSPECTION OR REPAIRS. THE MANUFACTURER WAS CONTACTED AND THEY ADVISED THE CONTACT THAT THE VEHICLE WAS NOT INCLUDED IN THE RECALL AND PROVIDED NO FURTHER AS…
Read full complaint
TL* THE CONTACT OWNS A 1991 FORD F250. THE CONTACT STATED THAT GASOLINE FUEL WAS LEAKING FROM THE VEHICLE AND ONTO THE DRIVEWAY. THE VEHICLE WAS NOT TAKEN TO THE DEALER FOR INSPECTION OR REPAIRS. THE MANUFACTURER WAS CONTACTED AND THEY ADVISED THE CONTACT THAT THE VEHICLE WAS NOT INCLUDED IN THE RECALL AND PROVIDED NO FURTHER ASSISTANCE. THE FAILURE MILEAGE WAS 102,311 AND THE CURRENT MILEAGE WAS 102,622. ..UPDATED 09/07/12 *BF UPDATED 09/17/2012 *JS
TL* THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT AFTER REFUELING THE VEHICLE, GASOLINE WOULD OVERFLOW FROM THE REAR FUEL TANK INTO THE FRONT FUEL TANK, CAUSING SPILLAGE. THE CONTACT BELIEVED THAT THE FUEL PUMP WAS DEFECTIVE. THE VEHICLE WAS TAKEN TO THE DEALER WHO ADVISED THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA…
Read full complaint
TL* THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT AFTER REFUELING THE VEHICLE, GASOLINE WOULD OVERFLOW FROM THE REAR FUEL TANK INTO THE FRONT FUEL TANK, CAUSING SPILLAGE. THE CONTACT BELIEVED THAT THE FUEL PUMP WAS DEFECTIVE. THE VEHICLE WAS TAKEN TO THE DEALER WHO ADVISED THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY). THE DEALER ADVISED THAT THE ENTIRE FUEL TANK WOULD NEED REPLACING. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE VEHICLE WAS NOT REPAIRED AND THE VIN WAS UNAVAILABLE. THE FAILURE MILEAGE WAS 150,000.
TL*THE CONTACT OWNS A 1991 FORD F250. THE CONTACT STATED WHILE DRIVING APPROXIMATELY 45 MPH, HE NOTICED GASOLINE SPILLING OUT OF THE TANK. PRIOR TO THE SPILL, HE SMELLED A GASOLINE ODOR FOR ABOUT 6 MONTHS. THE VEHICLE WAS INSPECTED BY PEPBOYS WHO INFORMED THE CONTACT THAT THE FUEL TANK SELECTOR NEEDED TO BE REPLACED. THE VIN WAS…
Read full complaint
TL*THE CONTACT OWNS A 1991 FORD F250. THE CONTACT STATED WHILE DRIVING APPROXIMATELY 45 MPH, HE NOTICED GASOLINE SPILLING OUT OF THE TANK. PRIOR TO THE SPILL, HE SMELLED A GASOLINE ODOR FOR ABOUT 6 MONTHS. THE VEHICLE WAS INSPECTED BY PEPBOYS WHO INFORMED THE CONTACT THAT THE FUEL TANK SELECTOR NEEDED TO BE REPLACED. THE VIN WAS UNKNOWN. THE VEHICLE WAS REPAIRED. THE FAILURE MILEAGE WAS 38,525.
TL*THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT WHEN HE FILLED THE FRONT TANK, THE FUEL WOULD BE SHIFTED TO THE REAR TANK. THE FAILURE OCCURRED EVERYTIME HE FUELED THE VEHICLE. THE CONTACT STATED THAT BECAUSE OF THE FAILURE, A PRESSURE WAS CREATED WITHIN THE TWO TANKS. THE VEHICLE. THE CONTACT CALLED THE DEALERSH…
Read full complaint
TL*THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT WHEN HE FILLED THE FRONT TANK, THE FUEL WOULD BE SHIFTED TO THE REAR TANK. THE FAILURE OCCURRED EVERYTIME HE FUELED THE VEHICLE. THE CONTACT STATED THAT BECAUSE OF THE FAILURE, A PRESSURE WAS CREATED WITHIN THE TWO TANKS. THE VEHICLE. THE CONTACT CALLED THE DEALERSHIP AND REFERENCED RECALL 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY) AND WAS TOLD THAT THERE WERE NO ACTIVE RECALLS ON HIS VEHICLE. THE CONTACT CALLED THE MANUFACTURER WHO VERIFIED THAT THERE WERE NO ACTIVE RECALLS FOR THE VEHICLE. THE VEHICLE HAD NOT BEEN REPAIRED. THE CURRENT MILEAGE WAS APPROXIMATELY 250,000. THE FAILURE MILEAGE WAS APPROXIMATELY 50,000.
DISCOVERER A/T TIRES SIZE LT265/75R16 CATASTROPHICALLY FAILED WHILE DRIVING AT HIGHWAY SPEED. TREAD COMPLETELY PEELED OFF. HAD ONLY BEEN DRIVING FOR 30 MINUTES AND OUTSIDE TEMPERATURE WAS 70 DEGREES F. TIRES HAD ABOUT 23,000 MILES ON THEM. 1-2 YEARS PREVIOUSLY, THE SAME TYPE TIRE ON OPPOSITE WHEEL DEVELOPED A BULGE IN THE SI…
Read full complaint
DISCOVERER A/T TIRES SIZE LT265/75R16 CATASTROPHICALLY FAILED WHILE DRIVING AT HIGHWAY SPEED. TREAD COMPLETELY PEELED OFF. HAD ONLY BEEN DRIVING FOR 30 MINUTES AND OUTSIDE TEMPERATURE WAS 70 DEGREES F. TIRES HAD ABOUT 23,000 MILES ON THEM. 1-2 YEARS PREVIOUSLY, THE SAME TYPE TIRE ON OPPOSITE WHEEL DEVELOPED A BULGE IN THE SIDEWALL AND HAD TO BE REPLACED. *TR
Official recalls
596V071000 · Electrical System:ignition
Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
94V040000 · Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
93V066000 · Steering: Steering Wheel/handle Bar
Apr 27, 1993
KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.
Consequence & remedy
Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.
Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.
92V026000 · Service Brakes, Hydraulic:foundation Components:drum:shoes/linings
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93022 · Idle Air Spd Ctrl Vlv Malf
Opened Jul 30, 1993 · Closed Aug 31, 1994
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
PE93010 · Idle Air Spd Ctrl Vlv Malf
Opened Mar 2, 1993 · Closed Jul 30, 1993
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
Illustration