← New search

2005 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2005 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

800 reports with mileage · 91 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 469 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 68 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

11 crash reports7 fire reports10 injury reports

What owners actually said

891 reports
Mileage unknown · Dec 29, 2011
Latches/locks/linkagesStructure

AFTER A FREEZE DURING THE NIGHT, I WENT TO OPEN THE DRIVER SIDE DOOR. THE DOOR LATCH CABLE SNAPPED THE FIRST TIME I TRIED IT. THIS NOW POSES A HAZARD IF IN THE CASE OF AN EMERGENCY I CANNOT OPEN THE DRIVER'S DOOR. *KB

NHTSA ODI #10441610

75,000 miles · Dec 22, 2011
Engine And Engine Cooling

BOTH EXHAUST MANIFOLDS HAVE GONE BAD DUE TO CRACKS AND THUS HAVE EXHAUST LEAKS. *TR

NHTSA ODI #10441023

92,000 miles · Dec 13, 2011
Power Train

VEHICLE REAR DIFFERENTIAL FAILED WITH OUT CAUSE. WITH ANY SLIGHT TURN OF THE WHEEL THE ENTIRE VEHICLE WOULD JUMP AND A LOUD KNOCKING SOUND WAS HERD AT THE REAR END. NISSAN DEALERSHIP INFORMED ME THAT THIS SEEMS TO BE AN ISSUE WITH THE VENT TUBES CORRODED CAUSING PRESSURE TO BUILD UP IN THE REAR DIFFERENTIAL AND THE SPYDER GEAR…

Read full complaint

VEHICLE REAR DIFFERENTIAL FAILED WITH OUT CAUSE. WITH ANY SLIGHT TURN OF THE WHEEL THE ENTIRE VEHICLE WOULD JUMP AND A LOUD KNOCKING SOUND WAS HERD AT THE REAR END. NISSAN DEALERSHIP INFORMED ME THAT THIS SEEMS TO BE AN ISSUE WITH THE VENT TUBES CORRODED CAUSING PRESSURE TO BUILD UP IN THE REAR DIFFERENTIAL AND THE SPYDER GEAR(S) FAIL. NISSAN WILL NOT ISSUE A RECALL FOR THIS ISSUE AND DOES NOT SUPPLY REBUILD PARTS FOR THE VEHICLE- THEIR ONLY FIX IS FOR ME TO PURCHASE A NEW REAR AXLE. SEARCHING ON GOOGLE HAS REVIEWED 168,000 HITS FOR THIS PROBLEM. I FIND IT DIFFICULT TO BELIEVE THAT THIS IS AN ISOLATED ISSUE. MY LOCAL TRANSMISSION SHOP IS UNABLE TO LOCATE A USED REAR AXLE AS DEMAND FOR THESE PARTS IS EXTREMELY HIGH. HAD THIS HAPPENED ON THE HIGHWAY IT PROBABLY WOULD HAVE CAUSED A FATAL ACCIDENT AS A SUDDEN LOCKING OF THE REAR END AT 60 MPH PLUS WOULD CAUSE A LOSS OF CONTROL. *TR

NHTSA ODI #10439820

150,000 miles · Dec 13, 2011
Fuel System, Gasoline

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT WHILE DRIVING 50 MPH, THE VEHICLE STALLED. THE CONTACT ALSO STATED THAT THE FUEL GAUGE DISPLAYED A READING INDICATING THAT FUEL WAS IN THE FUEL TANK AT THE TIME OF THE FAILURE. THE VEHICLE WAS TOWED TO AN INDEPENDENT MECHANIC AND THE CONTACT WAS ADVISED TO TAKE TH…

Read full complaint

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT WHILE DRIVING 50 MPH, THE VEHICLE STALLED. THE CONTACT ALSO STATED THAT THE FUEL GAUGE DISPLAYED A READING INDICATING THAT FUEL WAS IN THE FUEL TANK AT THE TIME OF THE FAILURE. THE VEHICLE WAS TOWED TO AN INDEPENDENT MECHANIC AND THE CONTACT WAS ADVISED TO TAKE THE VEHICLE TO AN AUTHORIZED DEALER. THE VEHICLE WAS NOT REPAIRED. THE FAILURE RECURRED WHILE DRIVING 45 MPH. THE VEHICLE WAS TAKEN TO ANOTHER INDEPENDENT REPAIR SHOP AND THE CONTACT WAS INFORMED OF THE RECALL ASSOCIATED WITH NHTSA CAMPAIGN ID NUMBER 10V074000 (FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM). THE MANUFACTURER WAS MADE AWARE OF THE FAILURE AND INFORMED THE CONTACT THAT THE VEHICLE WAS NOT INCLUDED IN THE RECALL. THE FAILURE MILEAGE WAS 150,000.

NHTSA ODI #10439803

Mileage unknown · Dec 1, 2011
Equipment Adaptive/mobilityPower Train

2005 NISSAN TITAN KING CAB 2X4 LEAKING OIL FROM BOTH SIDE OF THE AXLE. PROBLEM AXLE SEEK FAILURE. UPON TAKING THE TRUCK INTO THE DEALERSHIP FOR CHECKUP AND THEY QUOTED ME FOR ABOUT $1700.00 IN REPAIRS. AS PER THERE TSB THEY WILL REPLACE BOTH AXLE SEALS AND AXLE "TSB NTB10-032" IF THE SEALS FAIL ON MOST OF THE TITAN'S SHOUL…

Read full complaint

2005 NISSAN TITAN KING CAB 2X4 LEAKING OIL FROM BOTH SIDE OF THE AXLE. PROBLEM AXLE SEEK FAILURE. UPON TAKING THE TRUCK INTO THE DEALERSHIP FOR CHECKUP AND THEY QUOTED ME FOR ABOUT $1700.00 IN REPAIRS. AS PER THERE TSB THEY WILL REPLACE BOTH AXLE SEALS AND AXLE "TSB NTB10-032" IF THE SEALS FAIL ON MOST OF THE TITAN'S SHOULDN'T NISSAN DO A RECALL ON THIS PLUS WHEN I WAS THERE THE SERVICE MAN STATED THAT THERE TSB SAYS TO REPLACE BOTH AXLE WHICH DRIVES UP THE COST INSTEAD OF JUST REPLACING THE AXLE SEAL. *TR

NHTSA ODI #10437963

Mileage unknown · Nov 30, 2011
Suspension

2005 NISSAN TITAN BOTH REAR AXLE SEAL ARE LEAKING AXLE FLUID. *KB

NHTSA ODI #10437889

95,000 miles · Nov 20, 2011
Power Train

I WAS IN NEW YORK FOR THE WEEK. I WAS CURRENTLY OUT SPOTTING DEER, I WENT TO TURN AROUND, I PUT THE TRUCK IN REVERSE AND IT SOUNDED LIKE MY REAR END BLEW UP. I THEN CONTINUED TO CAMP. THE NEXT DAY I WENT TO DRIVE IT AND IT POPPEDLIKE CRAZY MAKING A BIG NOISE IN REAR. I DROVE IT TO A GARAGE AND THEY CHECKED MY REAR DIFFERENTIAL…

Read full complaint

I WAS IN NEW YORK FOR THE WEEK. I WAS CURRENTLY OUT SPOTTING DEER, I WENT TO TURN AROUND, I PUT THE TRUCK IN REVERSE AND IT SOUNDED LIKE MY REAR END BLEW UP. I THEN CONTINUED TO CAMP. THE NEXT DAY I WENT TO DRIVE IT AND IT POPPEDLIKE CRAZY MAKING A BIG NOISE IN REAR. I DROVE IT TO A GARAGE AND THEY CHECKED MY REAR DIFFERENTIAL AND SAID MY SPIDER GEARS IN THE REAR END SNAPPED. THERE WAS PIECES OF GEARS ALL THROUGH MY REAR DIFFERENTIAL. THIS IS A DANGEROUS THING THAT CAN HAPPEN AND HAS BEEN HAPPENING WITH NISSAN TITANS. I NOTIFIED NISSAN AND WAS TOLD TO TAKE IT TO A NISSAN GARAGE, THE CLOSEST GARAGE IS 47 MILES I WILL HAVE TO PAY FOR TOWING AND EVERYTHING THERE IS NO RECALL ON THE REAR AXLES BUT THERE SHOULD BE BECAUSE THIS IS HAPPENING ALL OVER. TITAN REAR ENDS ARE TO SMALL FOR THE TRUCK. ALSO IT IS GOING TO COST AROUND 3000 BECAUSE NISSAN DOES NOT MAKE THE PARTS FOR REAR AXLE, HOW PATHETIC IS THAT! *TR

NHTSA ODI #10436498

103,000 miles · Nov 17, 2011
Fuel System, Gasoline

THE INSTRUMENT PANEL FUEL GAUGE DISPLAYED THAT THE VEHICLE STILL HAD FUEL. THE VEHICLE STALLED ON THE HIGHWAY, IN TRAFFIC, AND WAS OUT OF GAS. AT THE TIME WE HAD NO IDEA WHAT WAS WRONG AND ONLY KNEW IT WOULD NOT START. WE HAD THE VEHICLE TOWED TO THE NISSAN DEALERSHIP WHO DIAGNOSED IT WAS OUT OF GAS AND THE FUEL SENDER WAS FA…

Read full complaint

THE INSTRUMENT PANEL FUEL GAUGE DISPLAYED THAT THE VEHICLE STILL HAD FUEL. THE VEHICLE STALLED ON THE HIGHWAY, IN TRAFFIC, AND WAS OUT OF GAS. AT THE TIME WE HAD NO IDEA WHAT WAS WRONG AND ONLY KNEW IT WOULD NOT START. WE HAD THE VEHICLE TOWED TO THE NISSAN DEALERSHIP WHO DIAGNOSED IT WAS OUT OF GAS AND THE FUEL SENDER WAS FAULTY. THE FUEL SENDER RESIDES INSIDE THE FUEL TANK ACCORDING TO THE DEALERSHIP BUT THEY WILL NOT FIX IT AT THEIR EXPENSE. OUR PARTICULAR VIN # IS NOT COVERED FOR THE IDENTICAL ISSUE THAT IS UNDER A CURRENT RECALL. *TR

NHTSA ODI #10436215

123,700 miles · Nov 15, 2011
Fuel System, Other

AT HIGHWAY SPEED, VEHICLE SHUT OFF AND WOULD NOT RESTART STRANDING WIFE AND KIDS ON HIGHWAY. THE FUEL GAUGE SHOWED 1/4 TANK OF GAS, BUT IT WAS LATER FOUND THAT THE TANK WAS EMPTY. SAME CONDITION AS DOCUMENTED IN NHTSA CAMPAIGN 10V074000, BUT NISSAN CORP. STATED THAT VEHICLE IS NOT COVERED UNDER PREVIOUS RECALL BECAUSE VIN RANG…

Read full complaint

AT HIGHWAY SPEED, VEHICLE SHUT OFF AND WOULD NOT RESTART STRANDING WIFE AND KIDS ON HIGHWAY. THE FUEL GAUGE SHOWED 1/4 TANK OF GAS, BUT IT WAS LATER FOUND THAT THE TANK WAS EMPTY. SAME CONDITION AS DOCUMENTED IN NHTSA CAMPAIGN 10V074000, BUT NISSAN CORP. STATED THAT VEHICLE IS NOT COVERED UNDER PREVIOUS RECALL BECAUSE VIN RANGE/MANUFACTURE DATE IS PRIOR TO SPECIFICATIONS OF RECALL. NISSAN HAS STATED THAT THERE IS NOTHING THEY CAN DO AND HAS OFFERED NO ASSISTANCE IN THIS MATTER. *SAFETY ISSUE - A MAJOR COLLISION COULD HAVE OCCURRED AT HIGHWAY SPEED DUE TO VEHICLE'S INEXPLICABLE SHUT DOWN. *TR

NHTSA ODI #10435986

40,000 miles · Nov 12, 2011
Power Train

I HAD BOTH REAR WHEEL AXLE SEALS THAT STARTED TO LEAK REPLACED ON MY NISSAN TITAN. (BOTH REPLACED BY THE NISSAN DEALER)THE RIGHT REAR AT 40,527 AND THE LEFT REAR AT 55,638. NOW AGAIN THE RIGHT REAR IS LEAKING AGAIN AT 79,000. I TALKED TO THE DEALER ABOUT THIS PROBLEM AND WAS TOLD THEY DON'T SEE A LOT OF PROBLEMS WITH THESE WHEE…

Read full complaint

I HAD BOTH REAR WHEEL AXLE SEALS THAT STARTED TO LEAK REPLACED ON MY NISSAN TITAN. (BOTH REPLACED BY THE NISSAN DEALER)THE RIGHT REAR AT 40,527 AND THE LEFT REAR AT 55,638. NOW AGAIN THE RIGHT REAR IS LEAKING AGAIN AT 79,000. I TALKED TO THE DEALER ABOUT THIS PROBLEM AND WAS TOLD THEY DON'T SEE A LOT OF PROBLEMS WITH THESE WHEEL SEALS LEAKING. FROM WHAT I READ ABOUT OTHER OWNERS OF NISSAN TITANS I DISAGREE. I BELIEVE THIS IS A SERIOUS PROBLEM THAT NEEDS TO BE LOOKED AT. GETTING OIL ON THE BRAKES IS A ACCIDENT WAITING TO HAPPEN. NEED HELP HERE. THANKS. *TR

NHTSA ODI #10435341

Official recalls

4

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.