NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
891 reports98,000 miles · Jul 6, 2013
Power Train
I TOOK MY TRUCK TO AN OIL CHANGE AND THEY NOTICE THAT THE REAR DIFFERENTIAL WAS LEAKING OIL ON THE RIGHT SIDE THEY TOLD ME THAT THE SEALS ARE BROKEN SO I TOOK IT TO THE DEALER TO BE FIXED. WHEN I GOT HOME LOOK IT UP IN THE INTERNET AND IT I FIND OUT THAT THIS HAPPENS QUITE OFTEN AND I THINK THAT NISSAN SHOULD DO SOMETHING TO C…
Read full complaint
I TOOK MY TRUCK TO AN OIL CHANGE AND THEY NOTICE THAT THE REAR DIFFERENTIAL WAS LEAKING OIL ON THE RIGHT SIDE THEY TOLD ME THAT THE SEALS ARE BROKEN SO I TOOK IT TO THE DEALER TO BE FIXED. WHEN I GOT HOME LOOK IT UP IN THE INTERNET AND IT I FIND OUT THAT THIS HAPPENS QUITE OFTEN AND I THINK THAT NISSAN SHOULD DO SOMETHING TO CORRECT THIS PROBLEM BECAUSE DIFFERENTIAL FLUID CAN GET INTO THE BRAKES AND THIS IS A SAFETY ISSUE. *TR
NHTSA ODI #10523438
170,000 miles · Jul 1, 2013
Engine
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE INTERIOR CABIN WOULD BECOME FILLED WITH EXHAUST FUMES. THE CONTACT TOOK THE VEHICLE TO THE DEALER FOR DIAGNOSTIC TESTING AND WAS ADVISED THAT THE EXHAUST MANIFOLD WAS DEFECTIVE. THE DEALER REPLACED THE EXHAUST MANIFOLD BUT THE REPAIR DID NOT REMEDY THE ISSUE. …
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE INTERIOR CABIN WOULD BECOME FILLED WITH EXHAUST FUMES. THE CONTACT TOOK THE VEHICLE TO THE DEALER FOR DIAGNOSTIC TESTING AND WAS ADVISED THAT THE EXHAUST MANIFOLD WAS DEFECTIVE. THE DEALER REPLACED THE EXHAUST MANIFOLD BUT THE REPAIR DID NOT REMEDY THE ISSUE. THE DEALER REPLACED THE EXHAUST MANIFOLD FIVE MORE TIMES BUT THE DEFECT WAS NOT REMEDIED. THE FAILURE MILEAGE WAS 170,000. THE VIN WAS NOT AVAILABLE.
NHTSA ODI #10522721
60,000 miles · Jun 23, 2013
Fuel/propulsion System
WAS GIVEN A CASE NUMBER [XXX], EXT [XXX], WAS TOLD BY[XXX]TO GO BACK TO THE NISSAN DEALERSHIP AND HAVE THEM PERFORM A DIAGNOSTIC ON THE FUEL SYSTEM. AND THEN CALL HER BACK WITH THE RESULTS. I DID THIS AT A COST OF $110.00 TO ME. WHEN I CALL BACK AT THE NUMBER SHE HAD GIVEN ME ALL MY CALLS GO TO VOICE MAIL. NO ONE HAS EVER CAL…
Read full complaint
WAS GIVEN A CASE NUMBER [XXX], EXT [XXX], WAS TOLD BY[XXX]TO GO BACK TO THE NISSAN DEALERSHIP AND HAVE THEM PERFORM A DIAGNOSTIC ON THE FUEL SYSTEM. AND THEN CALL HER BACK WITH THE RESULTS. I DID THIS AT A COST OF $110.00 TO ME. WHEN I CALL BACK AT THE NUMBER SHE HAD GIVEN ME ALL MY CALLS GO TO VOICE MAIL. NO ONE HAS EVER CALLED ME BACK FROM NISSAN. 1-800-647-7261 INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6). *TR
NHTSA ODI #10521286
60,000 miles · Jun 7, 2013
Fuel/propulsion System
FUEL GAUGE BOUNCING AROUND GOING FROM A HALF A TANK OF GAS TO A QUARTER TANK OF GAS. CALL NISSAN DEALERSHIP ALSO COMPANY. THEY SAID THERE IS NO RECALL FOR THE FUEL SENDING UNIT. BUT I SEE ON THEIR WEBSITE THAT THERE IS. *TR
NHTSA ODI #10515720
90,000 miles · Jun 7, 2013
Electrical System
TL * THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE AIR BAG WARNING LIGHT ILLUMINATED. THE VEHICLE WAS NOT TAKEN TO THE DEALER TO BE DIAGNOSED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE AND STATED THAT THE VEHICLE WAS INCLUDED IN NHTSA CAMPAIGN ID NUMBER 06V459000 (ELECTRICAL SYSTEM) BUT THE PARTS NEEDED TO…
Read full complaint
TL * THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE AIR BAG WARNING LIGHT ILLUMINATED. THE VEHICLE WAS NOT TAKEN TO THE DEALER TO BE DIAGNOSED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE AND STATED THAT THE VEHICLE WAS INCLUDED IN NHTSA CAMPAIGN ID NUMBER 06V459000 (ELECTRICAL SYSTEM) BUT THE PARTS NEEDED TO COMPLETE THE REPAIR WERE NOT AVAILABLE. THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 90,000 AND THE CURRENT MILEAGE WAS 106,000. *TR
NHTSA ODI #10515680
112,000 miles · Jun 6, 2013
Engine
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT WHILE DRIVING VARIOUS SPEEDS, THE VEHICLE EMITTED A LOUD NOISE. UPON INSPECTION, IT WAS FOUND THAT THE EXHAUST MANIFOLD WAS CRACKED. THE CONTACT ALSO MENTIONED THAT EXHAUST FUMES WERE SMELLED WHILE IN THE CABIN. THE VEHICLE WAS TAKEN TO THE DEALER WHERE THE FAILUR…
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT WHILE DRIVING VARIOUS SPEEDS, THE VEHICLE EMITTED A LOUD NOISE. UPON INSPECTION, IT WAS FOUND THAT THE EXHAUST MANIFOLD WAS CRACKED. THE CONTACT ALSO MENTIONED THAT EXHAUST FUMES WERE SMELLED WHILE IN THE CABIN. THE VEHICLE WAS TAKEN TO THE DEALER WHERE THE FAILURE WAS CONFIRMED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS CONTACTED ABOUT THE FAILURE. THE FAILURE MILEAGE WAS 112,000.
NHTSA ODI #10515449
80,000 miles · May 29, 2013
Power Train
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT WHILE DRIVING 40 MPH, THERE WAS A LOUD NOISE AS THE REAR WHEELS SEIZED. THE CONTACT NOTICED THAT THE DIFFERENTIAL WAS FRACTURED AND HAD BECOME SEPARATED. THE VEHICLE WAS TOWED TO A PRIVATE REPAIR SHOP HOWEVER, THE CAUSE OF FAILURE WAS NOT DETERMINED. THE VEHICLE W…
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT WHILE DRIVING 40 MPH, THERE WAS A LOUD NOISE AS THE REAR WHEELS SEIZED. THE CONTACT NOTICED THAT THE DIFFERENTIAL WAS FRACTURED AND HAD BECOME SEPARATED. THE VEHICLE WAS TOWED TO A PRIVATE REPAIR SHOP HOWEVER, THE CAUSE OF FAILURE WAS NOT DETERMINED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE WAS NOT REPORTED TO THE MANUFACTURER. THE FAILURE AND CURRENT MILEAGE WAS 80,000.
NHTSA ODI #10514104
150,000 miles · May 15, 2013
Fuel System, OtherFuel/propulsion System
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT HE NOTICED THAT THE FUEL GAUGE WAS NOT PROVIDING AN ACCURATE READING. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS. THE TECHNICIAN WAS UNABLE TO DIAGNOSE THE FAILURE. THERE WAS A RECALL UNDER NHTSA CAMPAIGN NUMBER: 10V074000 (FUEL SYSTEM, OTHER) THAT COULD HA…
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT HE NOTICED THAT THE FUEL GAUGE WAS NOT PROVIDING AN ACCURATE READING. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS. THE TECHNICIAN WAS UNABLE TO DIAGNOSE THE FAILURE. THERE WAS A RECALL UNDER NHTSA CAMPAIGN NUMBER: 10V074000 (FUEL SYSTEM, OTHER) THAT COULD HAVE BEEN RELATED TO THE FAILURE. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE AND STATED THE VEHICLE WAS NOT INCLUDED IN THE RECALL. THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 150,000. *TR
NHTSA ODI #10512077
67,500 miles · May 14, 2013
Power Train
WHEN STARTING FROM A COMPLETE STOP, THE REAR DIFFERENTIAL BROKE AND THE ENTIRE REAR DIFFERENTIAL AND AXLE ASSEMBLY HAD TO BE REPLACED AS A REBUILD KIT IS NOT AVAILABLE AT THE TIME. TOTAL REPAIR COSTS WERE $4,700. *TR
NHTSA ODI #10511838
95,000 miles · May 12, 2013
Fuel/propulsion SystemPower Train
THE SPIDER GEARS IN MY REAR DIFFERENTIAL SHEARED OFF, CAUSING CATASTROPHIC FAILURE OF MY REAR END. THIS HAS BEEN A HUGE PROBLEM WITH THE NISSAN TITANS, AND SHOULD BE ADDRESSED. *TR
NHTSA ODI #10511558
Official recalls
4Oct 28, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Mar 3, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Jun 27, 2008
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Nov 30, 2006
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.