NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
891 reports48,000 miles · Aug 18, 2013
Power TrainSuspension
FRONT DIFFERENTIAL STARTED MAKING NOISE, WHEN MECHANICS OPENED IT, THEY SAID IT WAS IMPOSSIBLE TO REBUILD AND I NEED A BRAND NEW ASSEMBLY. (TOO MUCH INTERNAL DAMAGE.) FOR THE MILEAGE THIS TRUCK HAS, THIS PART FAILED WAY TO EARLY. MECHANIC SAID IT HAPPENED BECAUSE OF ITS POOR DESIGN. NOW TRUCK HAS 60,000 MILES AND REAR DIFFERENTI…
Read full complaint
FRONT DIFFERENTIAL STARTED MAKING NOISE, WHEN MECHANICS OPENED IT, THEY SAID IT WAS IMPOSSIBLE TO REBUILD AND I NEED A BRAND NEW ASSEMBLY. (TOO MUCH INTERNAL DAMAGE.) FOR THE MILEAGE THIS TRUCK HAS, THIS PART FAILED WAY TO EARLY. MECHANIC SAID IT HAPPENED BECAUSE OF ITS POOR DESIGN. NOW TRUCK HAS 60,000 MILES AND REAR DIFFERENTIAL STARTED TO LEAK. *TR
NHTSA ODI #10535966
70,000 miles · Aug 16, 2013
EngineFire
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE EXHAUST MANIFOLD FAILED. THE CONTACT INSPECTED THE VEHICLE AND FOUND THAT THE EXHAUST MANIFOLD TAIL PIPE WAS FRACTURED DUE TO DEFECTIVE WELDING AND CAUSED THE TAIL PIPE TO MELT THE REAR BRAKE WIRES. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT MADE A…
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE EXHAUST MANIFOLD FAILED. THE CONTACT INSPECTED THE VEHICLE AND FOUND THAT THE EXHAUST MANIFOLD TAIL PIPE WAS FRACTURED DUE TO DEFECTIVE WELDING AND CAUSED THE TAIL PIPE TO MELT THE REAR BRAKE WIRES. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 70,000 AND THE CURRENT MILEAGE WAS 88,000.
NHTSA ODI #10535687
74,200 miles · Aug 14, 2013
Service BrakesVehicle Speed Control
WHILE MOVING FORWARD FROM PARK, THE REAR TIRES LOCKED UP. I REVERSED AND THEN MOVED FORWARD TO TRY TO FREE THE TIRES. THE EMERGENCY BRAKE WAS OFF. IT TOOK SEVERAL TIMES OF SHIFTING GEARS BEFORE THE VEHICLE WOULD MOVE FREELY. I RESEARCHED THE INTERNET AND FOUND SEVERAL OTHER TITAN OWNERS HAD THE SAME PROBLEM. THEY TRACED THE…
Read full complaint
WHILE MOVING FORWARD FROM PARK, THE REAR TIRES LOCKED UP. I REVERSED AND THEN MOVED FORWARD TO TRY TO FREE THE TIRES. THE EMERGENCY BRAKE WAS OFF. IT TOOK SEVERAL TIMES OF SHIFTING GEARS BEFORE THE VEHICLE WOULD MOVE FREELY. I RESEARCHED THE INTERNET AND FOUND SEVERAL OTHER TITAN OWNERS HAD THE SAME PROBLEM. THEY TRACED THE CAUSE TO THE REAR EMERGENCY BRAKE PADS DISLODGING FROM THE HUB AND BECOMING LODGED IN THE REAR ROTOR. MY MECHANIC REMOVED THE REAR ROTOR ON THE RIGHT SIDE AND THE EMERGENCY BRAKE PADS FELL OUT. THE LEFT SIDE PADS WERE STILL MOUNTED BUT WITH ONE POKE WITH A SCREWDRIVER, THE PADS FELL OUT. ONE YOUTUBE VIDEO SHOWS A TITAN WITH THIS PROBLEM BUT ADDITIONALLY THE BRAKE PAD BROKE THE REAR CALIPER BRACKET. *TR
NHTSA ODI #10535430
12,000 miles · Aug 13, 2013
EngineSuspension
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE REAR AXLE LEAKED ONTO THE BRAKES AND THE EXHAUST MANIFOLD WAS FRACTURED. THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS FOUND THAT THE MANIFOLD NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE CONTACT ALSO MENTIONED THAT THE VEHICLE WAS PREVIOUSLY RE…
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE REAR AXLE LEAKED ONTO THE BRAKES AND THE EXHAUST MANIFOLD WAS FRACTURED. THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS FOUND THAT THE MANIFOLD NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE CONTACT ALSO MENTIONED THAT THE VEHICLE WAS PREVIOUSLY REPAIRED UNDER A MANUFACTURER'S RECALL FOR THE SUSPENSION. THE MANUFACTURER WAS CONTACTED ABOUT THE FAILURE. THE FAILURE MILEAGE WAS 12,000.
NHTSA ODI #10535159
74,000 miles · Aug 9, 2013
Suspension
LEAF SPRING SQUEAKING NOISE AND ALSO JUST HAD THE REAR REPLACE ON THIS VEHICLE I JUST BOUGHT THIS VEHICLE A YEAR AGO I DON'T DO NO HAULING WAS SO EVER ON THIS TRUCK I DID SOME RESEARCH AND NISSAN KNOWS ABOUT THIS PROBLEM BUT THE DON'T WANT TO DO NOTHING REAR,SHACKLES,LEAF SPRING. *TR
NHTSA ODI #10534460
Mileage unknown · Aug 2, 2013
Engine
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THE VEHICLE BEGAN LOOSING POWER AND THE EXHAUST MANIFOLD WAS CRACKED. THE CONTACT TOOK THE VEHICLE TO THE DEALER AND IT WAS DETERMINED THAT BOTH THE LEFT AND RIGHT MANIFOLDS NEEDED TO BE REPLACED BECAUSE OF A LEAK. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS …
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THE VEHICLE BEGAN LOOSING POWER AND THE EXHAUST MANIFOLD WAS CRACKED. THE CONTACT TOOK THE VEHICLE TO THE DEALER AND IT WAS DETERMINED THAT BOTH THE LEFT AND RIGHT MANIFOLDS NEEDED TO BE REPLACED BECAUSE OF A LEAK. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS UNKNOWN, BUT THE CURRENT MILEAGE WAS 160,000.
NHTSA ODI #10533244
100,000 miles · Aug 2, 2013
Engine
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED WHILE DRIVING 60 MPH, THE WARNING LIGHT ILLUMINATED AND THE CONTACT SAW A CRACK IN THE MANIFOLD. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS BUT THEY WERE UNABLE TO DUPLICATE THE PROBLEM. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED. THE APPROX…
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED WHILE DRIVING 60 MPH, THE WARNING LIGHT ILLUMINATED AND THE CONTACT SAW A CRACK IN THE MANIFOLD. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS BUT THEY WERE UNABLE TO DUPLICATE THE PROBLEM. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED. THE APPROXIMATE FAILURE MILEAGE WAS 100,000.
NHTSA ODI #10533243
125,000 miles · Jul 30, 2013
Latches/locks/linkages
THE DRIVERS SIDE DOOR ACTUATOR FREEZES AND WILL EITHER NOT UNLOCK AND ALLOW YOU TO OPEN THE DOOR AT ALL OR MORE OFTEN, WILL FREEZE IN THE OPEN POSITION WHICH PREVENTS THE DOOR FROM LATCHING SHUT. APPARENTLY THIS IS A KNOWN ISSUE WHICH NISSAN'S MODEL ENGINEER IS AWARE OF AND THEY HAVE ISSUED SERVICE BULLETIN NTB05-118A FOR. *T…
Read full complaint
THE DRIVERS SIDE DOOR ACTUATOR FREEZES AND WILL EITHER NOT UNLOCK AND ALLOW YOU TO OPEN THE DOOR AT ALL OR MORE OFTEN, WILL FREEZE IN THE OPEN POSITION WHICH PREVENTS THE DOOR FROM LATCHING SHUT. APPARENTLY THIS IS A KNOWN ISSUE WHICH NISSAN'S MODEL ENGINEER IS AWARE OF AND THEY HAVE ISSUED SERVICE BULLETIN NTB05-118A FOR. *TR
NHTSA ODI #10532617
82,000 miles · Jul 21, 2013
Engine
FOR THE LAST YEAR I HAD HEARD A NOISE THAT SOUNDED LIKE AN EXHAUST LEAK. SMELLED FUMES INSIDE THE CAR. DEALER CONFIRMED MANIFOLD WAS CRACKED, BUT SINCE THE CAR HAD 82000 MILES ON IT, THEY WOULD NOT REPLACE IT. *TR
NHTSA ODI #10526023
52,500 miles · Jul 16, 2013
Fuel System, GasolineFuel System, Other
1ST INCIDENT OCCURRED DURING RUSH HOUR TRAFFIC. I WAS DRIVING AROUND 25MPH WHEN MY TITAN STARTED TO STALL AND THEN CAME TO A COMPLETE STOP, WAS JUST ABOUT REAR-END BY DELIVERY TRUCK. I WAS STUCK ON THE STREET IN THE MIDDLE OF TRAFFIC FOR 2 HOURS BEFORE A TOW TRUCK WAS ABLE TO COME TOW TRUCK. I HAD MECHANIC LOOK IT OVER AND IT …
Read full complaint
1ST INCIDENT OCCURRED DURING RUSH HOUR TRAFFIC. I WAS DRIVING AROUND 25MPH WHEN MY TITAN STARTED TO STALL AND THEN CAME TO A COMPLETE STOP, WAS JUST ABOUT REAR-END BY DELIVERY TRUCK. I WAS STUCK ON THE STREET IN THE MIDDLE OF TRAFFIC FOR 2 HOURS BEFORE A TOW TRUCK WAS ABLE TO COME TOW TRUCK. I HAD MECHANIC LOOK IT OVER AND IT CAME OUT THAT I HAD RUN OUT OF GAS, MECHANIC LOOKED AT FUEL GAUGE AND IT WAS READING OF TANK BUT WOULD NOT START. ONCE COUPLE GALLONS WERE ADDED TRUCK STARTED RIGHT UP. MECHANIC STATED THAT FUEL GAUGE IS READING WRONG, MECHANIC LOOKED UP TO SEE IF THERE WAS ANY RECALLS. THERE WAS A RECALL FOR THE 2005 NISSAN TITAN FOR THE FUEL SYSTEM NOT READING CORRECTLY. BUT DEALER STATED THAT MY VIN NUMBER DIDN'T FALL INTO THAT RECALL. MECHANIC STATED IT WOULD BE OVER $900 TO FIX. SO I HAD TO TELL THE MECHANIC NOT TO FIX IT. OVER THE YEARS, I HAVE RUN OUT OF GAS ABOUT 3 MORE TIMES DUE TO THE FUEL GAUGE NOT READING CORRECTLY. LAST TIME I RAN OUT OF GAS MY INFANT SON WAS IN TRUCK AND WAS JUST ABOUT SIDE SWIPED FROM ANOTHER VEHICLE AT AN INTERSECTION. I NEED TO DO WHAT NEEDS TO BE DONE TO GET MY NISSAN TITAN ADDED TO THIS RECALL, I CANNOT AFFORD TO PAY THIS TO BE FIXED. RECALL ID #68299 ? FUEL SYSTEM, OTHER: STORAGE:FUEL GAUGE SYSTEM. *TR
NHTSA ODI #10525238
Official recalls
4Oct 28, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Mar 3, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Jun 27, 2008
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Nov 30, 2006
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.