Owner reports · Recalls · Investigations

More warning signs than most Armada years

Owner complaints for the 2006 Nissan Armada are substantially higher than the model-year median of 23.

About this comparison →

When problems were reported

Mileage at the reported incident

230 reports with mileage · 36 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Service Brakes. Review the 138 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 51 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 24 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

14 crash reports13 fire reports9 injury reports

Wheels complaints

3 reports
Clear category filter
83,000 miles · Sep 11, 2014
Service BrakesVehicle Speed ControlWheels

I WAS DRIVING MY KIDS TO SCHOOL, AS I WAS REACHING A STOP SIGN I WENT TO HIT MY BRAKES WHEN ALL OF THE SUDDEN I HAD NO BRAKE POWER, MADE AN UGLY GRINDING NOISE AND STOPPED IN THE MIDDLE OF THE INTERSECTION LUCKILY THERE WERE NO KIDS CROSSING THE ROAD OR COULD OF BEEN SOMETHING REALLY BAD! PLEASE HELP US! *TR

NHTSA ODI #10632479

Mileage unknown · Dec 29, 2010
Wheels

2006 NISSAN ARMADA. CONSUMER WRITES REGARDING PROBLEMS WITH RIGHT FRONT WHEEL *TGW

NHTSA ODI #10374133

118,000 miles · Aug 25, 2010
Wheels

TL* THE CONTACT OWNS A 2006 NISSAN ARMADA. THE CONTACT NOTICED THE FRONT PASSENGER SIDE WHEEL WAS FRACTURED. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHERE THE CONTACT WAS ADVISED THAT THE VEHICLE SHOULD NOT BE EQUIPPED WITH CHROME WHEELS. THE CHROME WHEELS WERE PURCHASED AND INSTALLED AT AN AUTHORIZED DEALER WHEN THE CON…

Read full complaint

TL* THE CONTACT OWNS A 2006 NISSAN ARMADA. THE CONTACT NOTICED THE FRONT PASSENGER SIDE WHEEL WAS FRACTURED. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHERE THE CONTACT WAS ADVISED THAT THE VEHICLE SHOULD NOT BE EQUIPPED WITH CHROME WHEELS. THE CHROME WHEELS WERE PURCHASED AND INSTALLED AT AN AUTHORIZED DEALER WHEN THE CONTACT ORIGINALLY PURCHASED THE VEHICLE. A USED WHEEL WAS PURCHASED AND INSTALLED AS A REPLACEMENT. THE FAILURE MILEAGE WAS 118,000 AND THE CURRENT MILEAGE WAS 118,800.

NHTSA ODI #10351784

Official recalls

3

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.