NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
107 reportsMileage unknown · Apr 27, 2000
Electrical System
WHILE DRIVING AT NIGHT THROUGH MOUNTAINS ALL LIGHTS WENT OUT, AND CAR WAS FILLED WITH FUMES THAT MADE CONSUMER'S EYES WATER. IT SMELLED LIKE PLASTIC WIRES BURNING. VEHICLE WAS STILL DRIVEABLE AS CONSUMER PLAYED WITH SWITCH, AND THEN THEY CAME BACK ON. THE SMELL GOT SO BAD THAT CONSUMER TOOK SWITCH OUT AND FOUND THAT THE CON…
Read full complaint
WHILE DRIVING AT NIGHT THROUGH MOUNTAINS ALL LIGHTS WENT OUT, AND CAR WAS FILLED WITH FUMES THAT MADE CONSUMER'S EYES WATER. IT SMELLED LIKE PLASTIC WIRES BURNING. VEHICLE WAS STILL DRIVEABLE AS CONSUMER PLAYED WITH SWITCH, AND THEN THEY CAME BACK ON. THE SMELL GOT SO BAD THAT CONSUMER TOOK SWITCH OUT AND FOUND THAT THE CONNECTOR WAS MELTED, BUT NO FUSES HAD BLOWN, BOUGHT A NEW CONNECTOR. DEALER/FORD CONTACTED. *AK *ML
NHTSA ODI #861040
Mileage unknown · Mar 14, 2000
Fuel System, Gasoline
CONSUMER IS EXPERIENCING THE SAME PROBLEM THAT IS DESCRIBED IN RECALL #94V040000/ FUEL LINES, METALLIC. BUT THIS VEHICLE IS NOT INCLUDED IN THE RECALL. DEALER HAS BEEN CONTACTED. *AK *ML
NHTSA ODI #858502
Mileage unknown · Mar 2, 2000
Fuel System, Gasoline
MY GAS TANKS OVERFLOW OUT MY FILLER CAPS. I CALLED FORD THEY TOLD ME MY TRUCK HAD BEEN FIXED IN 1994 WHEN THEY SENT OUT A RECALL FOR THIS PROBLEM. WELL I STILL HAVE THE PROBLEM, AND WHEN I TALKED TO ONE OF YOUR REPS THEY TOLD ME THERE IS AN ONGOING IVESTIGATION FOR THIS PROBLEM. MAYBE THEIR FIX WASN'T A FIX AFTER ALL. WHAT SHOUL…
Read full complaint
MY GAS TANKS OVERFLOW OUT MY FILLER CAPS. I CALLED FORD THEY TOLD ME MY TRUCK HAD BEEN FIXED IN 1994 WHEN THEY SENT OUT A RECALL FOR THIS PROBLEM. WELL I STILL HAVE THE PROBLEM, AND WHEN I TALKED TO ONE OF YOUR REPS THEY TOLD ME THERE IS AN ONGOING IVESTIGATION FOR THIS PROBLEM. MAYBE THEIR FIX WASN'T A FIX AFTER ALL. WHAT SHOULD I DO ? DO I HAVE SOMEONE TRY TO FIX THE PROBLEM ACCORDING TO WHAT FORD SAYS TO FIX IT , OR AM I WASTING MONEY ON SOMETHING THEY REALLY DON'T HAVE A FIX FOR. ALSO IS FORD RESPONSIBLE TO FIX THE PROBLEM CORRECTLY { I MEAN IF IT WASN'T FIXED RIGHT THE FIRST TIME } THANK YOU. *AK
NHTSA ODI #719592
Mileage unknown · Feb 3, 2000
Fuel System, Gasoline
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP IS CAUSING A PORTION OF UNUSED FUEL TO RETURN TO THE SECOND TANK, RESULTING IN A FUEL LEAKAGE. ALSO, RECALL 93V125000/MANUFACTURER'S RECALL 93S68. HOWEVER, THIS VEHICLE IS NOT INCLUDED DUE TO VIN. *AK *ML
NHTSA ODI #856119
Mileage unknown · Jan 3, 2000
Engine And Engine CoolingFuel System, GasolinePower Train
THE CLUTCH FAILED. NLM
NHTSA ODI #550202
Mileage unknown · Jul 27, 1999
Exterior Lighting
HEADLIGHT SWITCH INTERMITTENTLY WORKS, THEN WOULD DROP OUT AND LEAVE DRIVER IN DARK. DEALER CONTACTED AND CANNOT REMEDY PROBLEM. RESULTS IN MELTING PLUG THAT CONNECTS TO SWITCH. PROBLEM STILL EXISTS. PROVIDE FURTHER INFORMATION. *AK
NHTSA ODI #843523
Mileage unknown · Jun 16, 1999
Service Brakes, HydraulicInjury
BRAKE SYSTEM MALFUNCTIONED DUE TO THE DESIGN OF THE BRAKES. VEHICLE HAD NO BRAKING ABILITY AT ALL, WHICH CAUSED A CRASH. *AK
NHTSA ODI #840123
Mileage unknown · Jun 2, 1999
Service Brakes, Hydraulic
BRAKE CALIPERS FAIL CONTINUALLY. MJS
NHTSA ODI #545909
Mileage unknown · May 8, 1999
Power Train
NO SUMMARY LISTED FOR THIS VEHICLE. *AK
NHTSA ODI #706338
Mileage unknown · Nov 2, 1998
Fuel System, Gasoline
THE FUEL TANK IS LEAKING AGAIN ON THIS VEHICLE. IT WAS REPAIRED UNDER A RECALL FOR LEAKING FUEL TANKS BEFORE. THERE IS NO CURRENT RECALL TO REPAIR THE PRIOR RECALL ITEMS. FORDS POSITION IN THE PAST HAS BEEN THEY ARE ONLY REQUIRED TO REPAIR A RECALL ONCE.
NHTSA ODI #700267
Official recalls
5Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Apr 27, 1993
KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.
Consequence & remedy
Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.
Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93022 · Idle Air Spd Ctrl Vlv Malf
Opened Jul 30, 1993 · Closed Aug 31, 1994
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
PE93010 · Idle Air Spd Ctrl Vlv Malf
Opened Mar 2, 1993 · Closed Jul 30, 1993
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available