OFFICIAL NHTSA RECALL
15V012000
Service Brakes
Reported Jan 14, 2015 · Nissan North America, Inc.
Summary
Nissan North America, Inc. (Nissan) is recalling certain model year 2014-2015 Nissan Pathfinder and Infiniti QX60 vehicles manufactured August 14, 2014, to November 5, 2014, and 2014-2015 Nissan Rogue vehicles manufactured August 12, 2014, to November 15, 2014. During the assembly process, the front wheel hub assembly fasteners may not have been properly torqued.
Consequence
The under-torqued fasteners may result in a brake caliper separating from the wheel assembly causing a reduction in braking performance or reduced steering control. These conditions increase the risk of a crash.
Remedy
Nissan will notify owners, and dealers will inspect the vehicles and tighten any loose bolts to the proper specification, free of charge. The recall began February 2, 2015. Owners may contact Nissan customer service at 1-800-647-7261.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
This campaign page uses the representative official campaign record. Applicability-specific source variants appear on the linked vehicle pages. Recall counts refer to campaigns, not affected vehicles.
Vehicle entries in this campaign
This is model-level recall history. It does not confirm whether a particular VIN is affected or has received the repair. Check with NHTSA ↗