TL* THE CONTACT OWNS A 2005 NISSAN TITAN. WHILE DRIVING 65 MPH, THE SUN ROOF DETACHED FROM THE VEHICLE. THERE WERE NO WARNING INDICATORS ILLUMINATED. THE VEHICLE WAS NOT DIAGNOSED OR REPAIRED. THE DEALER AND MANUFACTURER WERE NOT NOTIFIED. THE FAILURE MILEAGE WAS 128,000.
2005 Nissan Titan
Owner reports · Recalls · Investigations
More warning signs than most Titan years
Owner complaints for the 2005 Nissan Titan are substantially higher than the model-year median of 46.
About this comparison →How this year compares
Owner complaints by model year
Compare all Titan years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
800 reports with mileage · 91 unknown
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Power Train. Review the 469 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Fuel/propulsion System. Review the 68 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Suspension. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
891 reportsREAR SPEAKERS STOPPED WORKING. AFTER RESEARCHING FOUND THAT THE WIRING HARNESS WAS PINCHED IN THE DOOR JAMB ON MY KING CAB REAR DOORS. THE WIRES WERE CUT DUE TO EXTENSIVE WEAR AND BENDING.
THE FUEL GAUGE DOES NOT READ CORRECTLY BELOW APPROXIMATELY A QUARTER TANK. IT OCCASIONALLY WILL STICK AND FLUCTUATE BUT ALWAYS AROUND A QUARTER TANK AND BELOW. THE FIRST TIME I REALIZED THE PROBLEM I HAD TO HAVE MY TRUCK TOWED HOME, THINKING IT WAS SOMETHING MAJOR WHEN ALL I DID WAS RUN OUT OF GAS.
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. AFTER REFUELING THE VEHICLE, THE FUEL GAUGE DID NOT REFLECT THE AMOUNT OF FUEL INSIDE THE TANK. THE CONTACT STATED THAT THE FAILURE BEGAN APPROXIMATELY A MONTH AGO EACH TIME THE VEHICLE WAS FUELED. THE VEHICLE WAS TAKEN TO BILL SEIDLES NISSAN (10500 NW 12TH ST, MIAMI, FL 33172) WHERE IT …
Read full complaint
TL* THE CONTACT OWNS A 2005 NISSAN TITAN. AFTER REFUELING THE VEHICLE, THE FUEL GAUGE DID NOT REFLECT THE AMOUNT OF FUEL INSIDE THE TANK. THE CONTACT STATED THAT THE FAILURE BEGAN APPROXIMATELY A MONTH AGO EACH TIME THE VEHICLE WAS FUELED. THE VEHICLE WAS TAKEN TO BILL SEIDLES NISSAN (10500 NW 12TH ST, MIAMI, FL 33172) WHERE IT WAS DETERMINED THAT THE FUEL SENDING UNIT FAILED AND NEEDED REPLACEMENT. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE AND PROVIDED CASE NUMBER: 37522490. THE APPROXIMATE FAILURE MILEAGE WAS 140,000.
THE TRANSMISSION IS GOING OUT , NOW THE STEERING COLUMN SEPARATED FROM THE RACK AND PINION.
I UNDERSTAND THERE IS A RECALL ON 2005 THRU 2016 NISSAN TITANS FOR A FALTY GAS GAUGE BUT WAS TOLD THAT MY MODEL WAS NOT INCLUDED, I HAVE RUN OUT OF GAS WITH MY GAUGE SHOWING A 1/4 TANK OF FUEL UP TO ALMOST A 1/2 ON MY GAUGE BUT STILL RAN OUT OF FUEL, I TOOK MY TRUCK TO KEY WEST, FL. AND THE FUEL PUMP WENT OUT AND IT COST ME OVER…
Read full complaint
I UNDERSTAND THERE IS A RECALL ON 2005 THRU 2016 NISSAN TITANS FOR A FALTY GAS GAUGE BUT WAS TOLD THAT MY MODEL WAS NOT INCLUDED, I HAVE RUN OUT OF GAS WITH MY GAUGE SHOWING A 1/4 TANK OF FUEL UP TO ALMOST A 1/2 ON MY GAUGE BUT STILL RAN OUT OF FUEL, I TOOK MY TRUCK TO KEY WEST, FL. AND THE FUEL PUMP WENT OUT AND IT COST ME OVER $700 TO HAVE IT REPLACED. NOW MY GAS GAUGE IS OFF EVEN MORE THAN BEFORE
7/15/19 3:40 PM RUSH HOUR, BEGAN ENTERING A STATE RD TO CROSS BOTH LANES, TRAFFIC TRAVELING BOTH DIRECTIONS POSTED 55 MPH MOVED IN A STRAIGHT LINE HALFWAY INTO ONCOMING TRAFFIC, BUT SUDDENLY COULD NOT ACCELERATE. HAD TO QUICKLY REVERSE TO AVOID TBONE SITUATION FROM BOTH SIDES. SCARED ME HORRIBLY. BACKED UP MORE TRIED AGAIN TO …
Read full complaint
7/15/19 3:40 PM RUSH HOUR, BEGAN ENTERING A STATE RD TO CROSS BOTH LANES, TRAFFIC TRAVELING BOTH DIRECTIONS POSTED 55 MPH MOVED IN A STRAIGHT LINE HALFWAY INTO ONCOMING TRAFFIC, BUT SUDDENLY COULD NOT ACCELERATE. HAD TO QUICKLY REVERSE TO AVOID TBONE SITUATION FROM BOTH SIDES. SCARED ME HORRIBLY. BACKED UP MORE TRIED AGAIN TO GO FORWARD BEFORE ATTEMPTING TO CROSS BUT THE SAME THING HAPPENED. ENGINE WAS REVVING AT HIGH RPMS BUT TRUCK WOULD ONLY MOVE INCHES AT A TIME IN FORWARD MOTION. SO I TRAVELED BACKWARDS IN REVERSE THE LENGTH OF THE WHOLE STREET I WAS ON TO GET BACK TO MY DRIVEWAY AND BACKED UP MY DRIVEWAY WHERE I PARKED AND CALLED FOR A RIDE FROM MY HVAC TECH WHO WAS MEETING ME AT MY CHURCH TO INSTALL MUCH NEEDED AC UNIT. ONLY A COUPLE DAYS EARLIER, I HAD FLUID LEAKING AND TOOK THE TRUCK IN FOR REPAIR, THE TECH INFORMED ME THE TRANSMISSION FLUID AND ANTIFREEZE TANK HAD FAILED. THE ENGINE NEEDED TO BE FLUSHED, THE TANK, RADIATOR AND FLUID REPLACED. HE TOLD ME IT HAPPENED ALL THE TIME WITH NISSANS. I WILL ATTACH INVOICE FROM HIGHLY REPUTABLE REPAIR SHOP.
MY 2005 NISSAN TORNADOES IN THE MIDDLE OF THE OKLAHOMA TURNPIKE AND INTERSTATE I-44 CAUSING ONE OF THE LANES TO BE TEMPORARILY CLOSED. AFTER WARRINGTON A TOW TRUCK AND BEING TOWED TO THE NEAREST NISSAN DEALERSHIP, I WAS INFORMED THAT THE ONLY ISSUE WAS THE FUEL GAUGE WAS NOT REGISTERING THE CORRECT LEVEL OF GAS IN THE VEHICLE. …
Read full complaint
MY 2005 NISSAN TORNADOES IN THE MIDDLE OF THE OKLAHOMA TURNPIKE AND INTERSTATE I-44 CAUSING ONE OF THE LANES TO BE TEMPORARILY CLOSED. AFTER WARRINGTON A TOW TRUCK AND BEING TOWED TO THE NEAREST NISSAN DEALERSHIP, I WAS INFORMED THAT THE ONLY ISSUE WAS THE FUEL GAUGE WAS NOT REGISTERING THE CORRECT LEVEL OF GAS IN THE VEHICLE. ALTHOUGH THE GAUGE READ 3\8 OF A TANK REMAINING, THERE WAS NO FUEL IN THE TRUCK. THE NISSAN MECHANICS SAID THIS WAS A RECALL ON THIS YEAR TITAN, BUT ONCE HE CHECKED THE VIN, MY VEHICLE WAS NOT LISTED AS PART OF THE RECALL. THIS IS AN EXTREME SAFETY ISSUE AS THE VEHICLE CAN DIE AT ANY TIME IN ANY CONDITIONS CAUSING LANE CLOSURES OR WRECKS DUE TO THE SUDDEN FUEL ISSUE WITH NO WARNING. IF NISSAN HAS RECALLED FOR THIS EXACT ISSUE ON THE 2005 TITAN, AND THIS ISSUE IS AFFECTING A 2005 TITAN, I BELIEVE WITHOUT DOUBT THEY HAVE MISTAKENLY OMITTED CERTAIN VIN NUMBERS. IF THIS ISSUE ULTIMATELY CAUSES INJURY OR IN THE WORST SCENARIO, A FATALITY DUE TO THEIR VEHICLE DYING IN THE MIDDLE OF A TRAFFIC SITUATION, NISSAN SHOULD TAKE RESPONSIBILITY AND BE HELD ACCOUNTABLE.
FRONT DIFFERENTIAL HAS AXLE POPPED OUT, AFTER RESEARCHING I HAVE FOUND THAT THIS IS SUCH A COMMON PROBLEM THAT NISSAN HAS REDESIGNED THE FRONT DIFFERENTIAL TO CORRECT THE ISSUE. I HAVE TWO OPTIONS, FIRST TO TAKE TO A SHOP AND HAVE THEM REPLACE THE C CLIP ONLY TO FAIL AGAIN DOWN THE ROAD OR SECOND TO REPLACE THE FRONT DIFFERENTI…
Read full complaint
FRONT DIFFERENTIAL HAS AXLE POPPED OUT, AFTER RESEARCHING I HAVE FOUND THAT THIS IS SUCH A COMMON PROBLEM THAT NISSAN HAS REDESIGNED THE FRONT DIFFERENTIAL TO CORRECT THE ISSUE. I HAVE TWO OPTIONS, FIRST TO TAKE TO A SHOP AND HAVE THEM REPLACE THE C CLIP ONLY TO FAIL AGAIN DOWN THE ROAD OR SECOND TO REPLACE THE FRONT DIFFERENTIAL WITH THE FLAWED DESIGN FOR OVER $2500. WOULD LIKE TO SEE NISSAN ISSUE A RECALL TO CORRECT THE FLAWED DESIGN. THIS TRUCK IS USED ON ROAD ONLY AND I ONLY ENGAGE THE FOUR WHEEL DRIVE WHEN IT SNOWS AND ONLY USE AT LOW SPEEDS FOR A SHORT DISTANCE, THIS SHOULD NOT HAPPEN.
DASHBOARD LIGHT SHOWS AIR BAG ISSUE. HARNASS WAS REPLACED TWICE UNDER WARRANTY, THEY NOW WANT $800. TO FIX. AS ITS BEEN A SAFETY ISSUE AND FIXED TWICE I DON'T THINK I SHOULD HAVE TO PAY FOR THIS.
Official recalls
410V517000 · Engine And Engine Cooling
Oct 28, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
10V074000 · Fuel System, Other:storage:fuel Gauge System
Mar 3, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
08V284000 · Equipment:appliance:air Conditioner
Jun 27, 2008
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
06V459000 · Electrical System
Nov 30, 2006
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Illustration