← New search

2005 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2005 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

800 reports with mileage · 91 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 469 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 68 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

11 crash reports7 fire reports10 injury reports

What owners actually said

891 reports
26,523 miles · Jan 20, 2013
Steering

ON NOVEMBER 30, 2010 WHILE DRIVING MY SON TO SCHOOL MY STEERING WHEEL LOCKED-UP AND THE RACK & PINION LEAKED ALL THE OIL AND THE TRUCK WAS TOTALLY DISABLED. ALSO JULY 30, 2011(MILEAGE 28830) IT HAPPENED AGAIN WHILE GOING ON VACATION WITH MY FAMILY TO LOS ANGELES. WHILE DRIVING ON THE FREEWAY I HEARD SOME VIBRATION ON THE STEERI…

Read full complaint

ON NOVEMBER 30, 2010 WHILE DRIVING MY SON TO SCHOOL MY STEERING WHEEL LOCKED-UP AND THE RACK & PINION LEAKED ALL THE OIL AND THE TRUCK WAS TOTALLY DISABLED. ALSO JULY 30, 2011(MILEAGE 28830) IT HAPPENED AGAIN WHILE GOING ON VACATION WITH MY FAMILY TO LOS ANGELES. WHILE DRIVING ON THE FREEWAY I HEARD SOME VIBRATION ON THE STEERING WHEEL AND THE STEERING TOTALLY DISENGAGED FROM THE RACK & PINION. WE WERE NOT ABLE TO STEER THE WHEEL AT ALL THAT WE HAD TO STOP AND GET HELP. ALSO DECEMBER 29, 2012 (MILEAGE 33323) IT HAPPENED AGAIN WHILE PULLING THE TRUCK OUT OF MY GARAGE, THIS TIME IT LEAKED ALL THE OIL FROM THE RACK & PINION AND THE STEERING WHEEL WAS VERY STIFF TO DRIVE. I FEEL THAT THIS PROBLEM NEEDS TO BE ADDRESSED AS SOON AS POSSIBLE BECAUSE SOMEBODY CAN GET BADLY INJURED OR KILLED BECAUSE IT'S REALLY UNSAFE TO DRIVE THIS TRUCK. FUTURE NISSAN WHERE I BOUGHT THE TRUCK WILL NOT HELP ME WITH THIS ISSUE & ARE DENYING TO FIX MY TRUCK AGAIN BECAUSE THEY ARE SAYING IT'S THE SAME PROBLEM AGAIN. I ASK THAT YOU PLEASE HELP ME RESOLVE THIS MATTER. THANK YOU, [XXX] INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6). *TR

NHTSA ODI #10493592

128,000 miles · Jan 16, 2013
Suspension

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE WHILE DRIVING 40 MPH, THE REAR OF THE VEHICLE STARTED EXHIBITING A CLICKING SOUND AND FELT AS IT WERE ATTEMPTING TO SEIZE. THE CONTACT TOOK THE VEHICLE TO THE DEALER AND WAS TOLD THAT THE DRIVE KNUCKLE THAT WAS WITHIN THE DIFFERENTIAL HAD FAILED. THE DEALER AL…

Read full complaint

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE WHILE DRIVING 40 MPH, THE REAR OF THE VEHICLE STARTED EXHIBITING A CLICKING SOUND AND FELT AS IT WERE ATTEMPTING TO SEIZE. THE CONTACT TOOK THE VEHICLE TO THE DEALER AND WAS TOLD THAT THE DRIVE KNUCKLE THAT WAS WITHIN THE DIFFERENTIAL HAD FAILED. THE DEALER ALSO STATED THAT THE MANUFACTURER WOULD NOT REPLACE PARTS ON THE DIFFERENTIAL AND THE CONTACT WOULD HAVE TO PURCHASE AN ENTIRE REAR END FOR THE VEHICLE. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND THE CURRENT MILEAGE WAS 128,000.

NHTSA ODI #10493186

68,000 miles · Jan 9, 2013
Electrical SystemFuel System, OtherFuel/propulsion System

MY 2005 NISSAN TITAN IS EXHIBITING THE FAILURES AS OUTLINED IN NISSAN NHTSA RECALL CAMPAIGN 06V459000 (ELECTRICAL SYSTEM / WIRING HARNESS) AND NHTSA RECALL CAMPAIGN 10V074000 (FUEL SYSTEM / FUEL GAUGE SYSTEM). AFTER REPORTING MY ISSUES TO MY LOCAL NISSAN DEALER AND NISSAN CONSUMER AFFAIRS, I WAS TOLD MY VIN WAS NOT INCLUDED IN …

Read full complaint

MY 2005 NISSAN TITAN IS EXHIBITING THE FAILURES AS OUTLINED IN NISSAN NHTSA RECALL CAMPAIGN 06V459000 (ELECTRICAL SYSTEM / WIRING HARNESS) AND NHTSA RECALL CAMPAIGN 10V074000 (FUEL SYSTEM / FUEL GAUGE SYSTEM). AFTER REPORTING MY ISSUES TO MY LOCAL NISSAN DEALER AND NISSAN CONSUMER AFFAIRS, I WAS TOLD MY VIN WAS NOT INCLUDED IN EITHER RECALL CAMPAIGN. NISSAN CONSUMER AFFAIRS FINALLY GAVE ME A CASE NUMBER AND TOLD ME TO HAVE MY LOCAL NISSAN DEALER DIAGNOSE THE TRUCK AND PROVIDE THE WRITTEN DIAGNOSIS AND COST ESTIMATE TO A NISSAN CONSUMER AFFAIRS SPECIALIST. AFTER PAYING $85 FOR A DIAGNOSIS, THE LOCAL DEALER CONFIRMED IN A WRITTEN DIAGNOSIS AND ESTIMATE, THAT MY TRUCK WAS EXPERIENCING THE SAME FAILURES THAT THE 2 RECALLS CITE AND THAT MY TRUCK NEEDED THE SAME REMEDIES AS OUTLINED IN THE RECALLS. AFTER PROVIDING THIS INFORMATION TO THE NISSAN CONSUMER AFFAIRS SPECIALIST, NISSAN DECLINED TO COVER MY REPAIRS STATING THAT MY VIN WAS NOT INCLUDED, I DID NOT HAVE A COMPLETE HISTORY OF NISSAN SERVICING MY VEHICLE AND THAT MY VEHICLE WAS OUTSIDE THE LIMITED WARRANTY TERM. I KNEW MY TRUCK WAS OUTSIDE THE WARRANTY TERM, MY TRUCK NEEDS TO BE INCLUDED IN THE RECALL CAMPAIGN, WHICH HAS NOTHING TO DO WITH WARRANTY. NISSAN IS NEGLIGENT IN NOT INCLUDING MY TRUCK IN THE RECALL. I HAVE SEEN THIS SAME COMPLAINT FROM NUMEROUS OTHERS IN MY SAME SITUATION, ON THIS WEBSITE AND OTHER ONLINE FORUMS. THE RECALL NEEDS TO BE EXPANDED AS THEY OBVIOUSLY ARE NOT COVERING ALL VEHICLES AFFECTED BY THE FAILURES CITED. *TR

NHTSA ODI #10492049

94,472 miles · Dec 20, 2012
EngineFuel/propulsion System

LOUD EXHAUST SOUND COMING FROM THE FRONT, ON BOTH SIDES FOR THE ENGINE COMPARTMENT. DUE TO A CRACKED MANIFOLD. I COULD ALSO SMELL EXHAUST FUMES INSIDE. I KEEP THE WINDOW CRACKED OPEN WHEN I DRIVE FOR SAFETY REASONS, MOSTLY WHEN I HAVE MY WIFE AND KIDS IN THE VEHICLE. *TR

NHTSA ODI #10489343

93,475 miles · Dec 1, 2012
Power TrainService Brakes

AXLE SEAL FAILURE RESULTING IN OIL ON THE INSIDE OF BOTH REAR WHEELS AND OIL SOAKING REAR BRAKES RENDERING REAR BRAKES USELESS. *TR

NHTSA ODI #10486663

Mileage unknown · Nov 27, 2012
Fuel/propulsion System

I WAS ON MY WAY HOME, FROM AN ERRAND. THE ENGINE BEGAN TO RUN IRREGULARLY, THEN SHUT OFF. AT FIRST I DID NOT THINK I WAS OUR OF GAS BECAUSE THE FUEL GAUGE INDICATED THAT THERE WAS 1/4 TANK OF GAS. AFTER I TRIED A FEW TIMES AND FAILED TO GET IT STARTED I WALKED TO A GAS STATION AND GOT GAS, PUT IT IN THE TANK AND MY VEHICLE START…

Read full complaint

I WAS ON MY WAY HOME, FROM AN ERRAND. THE ENGINE BEGAN TO RUN IRREGULARLY, THEN SHUT OFF. AT FIRST I DID NOT THINK I WAS OUR OF GAS BECAUSE THE FUEL GAUGE INDICATED THAT THERE WAS 1/4 TANK OF GAS. AFTER I TRIED A FEW TIMES AND FAILED TO GET IT STARTED I WALKED TO A GAS STATION AND GOT GAS, PUT IT IN THE TANK AND MY VEHICLE STARTED. AT THE TIME OF THIS INCIDENT I WAS FORTUNATE THAT I WAS ABLE TO COAST INTO A WIDE DRIVEWAY AND AVOID BEING REAR ENDED. *TR

NHTSA ODI #10486205

Mileage unknown · Nov 14, 2012
Power Train

THE REAR END WAS REPLACED BEFORE I BOUGHT THE TRUCK AND JUST 3 YEARS LATER I HAD TO HAVE THE LEFT REAR AXLE SEAL REPLACED AND NOW IM HAVING TO REPLACE THE RIGHT SIDE AXLE SEAL. IM NOT TOO SURE THAT ITS NOT DAMAGED THE REAR END ITSELF. I HAD A CASE NUMBER WITH NISSAN NORTH AMERICA BUT BECAUSE OF THE TIME ITS BEEN OUT OF WARRANTY …

Read full complaint

THE REAR END WAS REPLACED BEFORE I BOUGHT THE TRUCK AND JUST 3 YEARS LATER I HAD TO HAVE THE LEFT REAR AXLE SEAL REPLACED AND NOW IM HAVING TO REPLACE THE RIGHT SIDE AXLE SEAL. IM NOT TOO SURE THAT ITS NOT DAMAGED THE REAR END ITSELF. I HAD A CASE NUMBER WITH NISSAN NORTH AMERICA BUT BECAUSE OF THE TIME ITS BEEN OUT OF WARRANTY THEY WONT REPLACE ANYTHING. THERE ARE TOO MANY PEOPLE WHO ARE HAVING THE SAME PROBLEM WITH THEIRS FOR THERE NOT TO BE SOMETHING DONE ABOUT IT. THESE SEALS SHOULD NOT BE GOING OUT THAT QUICK. *TR

NHTSA ODI #10484706

126,000 miles · Nov 14, 2012
Fuel/propulsion System

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE VEHICLE STALLED WITHOUT WARNING. THE FUEL LEVEL GAUGE DISPLAYED THE FUEL TANK AS BEING ONE QUARTER TANK FULL. THE VEHICLE WAS TOWED TO THE CONTACT'S RESIDENCE AND UPON FURTHER INSPECTION, IT WAS DISCOVERED THAT THE FUEL GAUGE MALFUNCTIONED AND WAS PROVIDING IN…

Read full complaint

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE VEHICLE STALLED WITHOUT WARNING. THE FUEL LEVEL GAUGE DISPLAYED THE FUEL TANK AS BEING ONE QUARTER TANK FULL. THE VEHICLE WAS TOWED TO THE CONTACT'S RESIDENCE AND UPON FURTHER INSPECTION, IT WAS DISCOVERED THAT THE FUEL GAUGE MALFUNCTIONED AND WAS PROVIDING INACCURATE FUEL LEVEL READINGS. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS CONTACTED ABOUT THE ISSUE AND INFORMED THE CONTACT THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA CAMPAIGN ID NUMBER: 10V074000 (FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM). THE FAILURE MILEAGE WAS 126,000 AND THE CURRENT MILEAGE WAS 137,405.

NHTSA ODI #10484651

56,000 miles · Nov 9, 2012
Engine

RADIATOR BEGAN LEAKING AND HAD TO BE REPLACED DUE TO CRACKS/SEPARATION OF PLASTIC COMPONENTS. *TR

NHTSA ODI #10483850

70,500 miles · Nov 9, 2012
Power Train

ORIGINALLY HEARD A LIGHT NOISE ON DECELERATION. WAS UNSURE OF ORIGIN OR SEVERITY BUT SUSPECTED BRAKE WEAR. NOISE CHANGED OVER THE COURSE OF A MONTH AND ON FINAL TRIP INTO NEARBY SHOP FOR DIAGNOSTICS IT HAD GROWN MUCH LOUDER WHILE DECELERATING. SHOP SUSPECTED REAR AXLE SEAL LEAK AND DIFFERENTIAL FAILURE. HAD TRUCK FLATBED TOW…

Read full complaint

ORIGINALLY HEARD A LIGHT NOISE ON DECELERATION. WAS UNSURE OF ORIGIN OR SEVERITY BUT SUSPECTED BRAKE WEAR. NOISE CHANGED OVER THE COURSE OF A MONTH AND ON FINAL TRIP INTO NEARBY SHOP FOR DIAGNOSTICS IT HAD GROWN MUCH LOUDER WHILE DECELERATING. SHOP SUSPECTED REAR AXLE SEAL LEAK AND DIFFERENTIAL FAILURE. HAD TRUCK FLATBED TOWED TO NEARBY NISSAN DEALERSHIP AND THEY FOUND LITTLE EVIDENCE OF LEAK AND PLENTY OF FLUID. YET THE DIFFERENTIAL HAD FAILED ENTIRELY. THEY SUSPECTED A RING AND PINION FAILURE THOUGH THEY DIDN'T CRACK OPEN THE CASE AS PARTS/LABOR MAKE REPAIR PROHIBITIVELY COSTLY. AFTER CHECKING SALVAGE PRICES THEY RECOMMENDED A FULL REPLACEMENT WITH A NEW NISSAN AXLE. I WAS LUCKY BECAUSE APPARENTLY THIS KIND OF DIFFERENTIAL FAILURE CAN LOCK UP THE REAR WHEELS WHILE DRIVING AT SPEED CAUSING A VERY DANGEROUS SITUATION. THIS TRUCK IS PRIMARILY DRIVEN AROUND TOWN. IT'S NEVER DRIVEN OFF-ROAD AND NEVER TOWED ANYTHING NOR CARRIED LARGE LOADS - IT'S BEEN BABIED. SEALS AND DIFFERENTIALS SHOULD NOT PREMATURELY FAIL IN A LIGHTLY DRIVEN, WELL-MAINTAINED VEHICLE WHICH WAS DESIGNED AND PROMOTED FOR HEAVY DUTY USE. *TR

NHTSA ODI #10483848

Official recalls

4

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.