← New search

2005 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2005 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

800 reports with mileage · 91 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 469 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 68 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

11 crash reports7 fire reports10 injury reports

Steering complaints

14 reports
Clear category filter
70,000 miles · Sep 12, 2009
SteeringSuspension

LEFT & RIGHT REAR SEALS LEAKING ON MY KING CAB 05 NISSAN TITAN. I HAD THE 60,000 MILE SERVICE DONE IN EARLY JULY 2009, AT THE DEALERSHIP. THE APPROXIMATE MILEAGE ON MY TRUCK AT THAT TIME WAS AROUND 66,000 MILES. UPON COMPLETING THE JOB, THE NEXT DAY, MOST OF THE TRANSMISSION FLUID LEAKED OUT OF MY TRUCK. THE DEALERSHIP CAME TO M…

Read full complaint

LEFT & RIGHT REAR SEALS LEAKING ON MY KING CAB 05 NISSAN TITAN. I HAD THE 60,000 MILE SERVICE DONE IN EARLY JULY 2009, AT THE DEALERSHIP. THE APPROXIMATE MILEAGE ON MY TRUCK AT THAT TIME WAS AROUND 66,000 MILES. UPON COMPLETING THE JOB, THE NEXT DAY, MOST OF THE TRANSMISSION FLUID LEAKED OUT OF MY TRUCK. THE DEALERSHIP CAME TO MY HOUSE AND REPAIRED THE LEAK AND TOPPED OFF THE TRANSMISSION FLUID. THEY SAID THAT IT WAS A FAILED HOSE CLAMP. THEY TOOK MY TRUCK BACK TO THE DEALERSHIP TO LOOK IT OVER TO CONFIRM THAT EVERYTHING ELSE WAS OK. THEY ALSO CHECK ON A FAN RECALL THAT WAS PENDING. THEY TOLD ME THAT NO REPAIRS WERE NECESSARY. A COUPLE OF WEEKS AGO I NOTICED THAT TRANSMISSION FLUID APPEARED TO BE LEAKING AGAIN FROM THE FRONT END. I TOOK MY TRUCK IN EARLIER THIS WEEK AND THE DEALERSHIP REPLACED A LEAKING TRANSMISSION HOSE AT NO CHARGE. THEY INFORMED ME AT THIS TIME THAT MY LEFT AND RIGHT REAR SEALS WERE LEAKING VERY BAD. THEY ALSO INFORMED ME THAT I HAVE A POWER STEERING LEAK. I DON'T UNDERSTAND WHY THESE ISSUES WERE NOT ADDRESSED IN JULY WHEN THE 60,000 MILE SERVICE WAS DONE UNLESS IT JUST RECENTLY STARTED. THEY TOLD ME HOW MUCH IT WILL COST TO DO THE REPAIRS AND ADVISED THAT I TAKE CARE OF IT ASAP! *TR

NHTSA ODI #10283739

29,815 miles · Apr 28, 2009
Service Brakes, HydraulicSteering

I PURCHASED A NEW NISSAN TITAN FROM ALAN KURTH DEALERSHIP MINOT, ND. MAY OF 2005. WITHIN THE YEAR I ASKED SEVERAL TIMES ABOUT THE "STRANGE" BRAKING EXPERIENCE. I NOTICED SOME VIBRATION FROM THE FRONT BRAKES THAT ALSO VIBRATED THE STEERING COLUMN. I WAS TOLD THAT THIS WAS NORMAL ON A TITAN HEAVY DUTY TRUCK . I AM NOT A MECHANIC …

Read full complaint

I PURCHASED A NEW NISSAN TITAN FROM ALAN KURTH DEALERSHIP MINOT, ND. MAY OF 2005. WITHIN THE YEAR I ASKED SEVERAL TIMES ABOUT THE "STRANGE" BRAKING EXPERIENCE. I NOTICED SOME VIBRATION FROM THE FRONT BRAKES THAT ALSO VIBRATED THE STEERING COLUMN. I WAS TOLD THAT THIS WAS NORMAL ON A TITAN HEAVY DUTY TRUCK . I AM NOT A MECHANIC AND TOOK THEIR WORD. THAT DEALERSHIP WENT OUT OF BUSINESS SHORTLY THEREAFTER AND THE ONLY OTHER NISSAN DEALER WAS IN BISMARK, A LONG WAY FROM WHERE I LIVED AT THE TIME. I DID TAKE IT TO THAT DEALER, BISMARK HONDA-NISSAN-HYUNDAI IN JULY OF 2006 IN RESPONSE TO A RECALL ABOUT ANOTHER ISSUE. NOTHING WAS MENTIONED BY THEM ABOUT ANY PROBLEM WITH THE BRAKES. THE TRUCK WAS NOT DRIVEN THAT MUCH, CURRENTLY HAS LESS THAN 30,000 MILES AND THE VIBRATION HAS BECOME WORSE AND WORSE ONCE I BROUGHT THE VEHICLE TO FLORIDA LAST FALL TO THE POINT THAT I TOOK IT TO MY MECHANIC. I WAS TOLD THEN AFTER THEY INSPECTED THE TRUCK ON APRIL 23RD. 2009 THAT NISSAN HAD IDENTIFIED A MAJOR PROBLEM WITH THE BRAKES ON THIS MODEL CALLED BRAKE JUDDER HE SUGGESTED I CALL NISSAN TO SEE HOW THEY WERE MANAGING THE PROBLEM. I TELEPHONED NISSAN CONSUMER OFFICE ON APRIL 24TH AND SPOKE WITH ANDY WHO OPENED A CASE FILE AND THAT NUMBER IS 6477694. HE SAID I WOULD HAVE TO BEGIN WITH THE LOCAL DEALER TO HAVE THEM INSPECT THE TRUCK SO I CONTACTED MAROONE NISSAN IN FT LAUDERDALE AND TOOK THE TRUCK IN ON APRIL 27, 2009. I DEALT WITH THE ASSISTANT SERVICE MANAGER. WHEN THEY HAD FINALLY FINISHED WITH THEIR INSPECTION HE TOLD ME THAT "NISSAN WOULD NOT PROVIDE A COURTESY REPAIR SINCE THEY HAD INITIALLY EXTENDED THE WARRANTY EXPIRED IN 2008. I HAD RESEARCHED THE ISSUE AND FOUND THE FOLLOWING THAT NISSAN FAILED TO PROVIDE. 1. THE ISSUE WAS SENT OUT TO ALL NISSAN SERVICE MANAGERS ON MARCH 16, 2005. THE REPAIRS WERE NOT MADE PRIOR TO MY PURCHASE. 2. THEY WERE DIRECTED TO SUPPLY A "LEGIBLE PHOTOCOPY" ABOUT THE WARRANTY EXTENSION. THEY DID NOT. THIS WAS DETAILED IN NISSAN ADVISORY NNAWB/05-01. *TR

NHTSA ODI #10267091

Mileage unknown · Dec 23, 2008
Power TrainSteering

2005 NISSAN TITAN LE, 86,800 MILES CURRENT -REAR AXLE SEALS LEAK - REPLACED AT 62,000 MILES (OUT OF WARRANTY) -REAR DRIVE SHAFT CRACKED - REPLACED AT 62,000 MILES (OUT OF WARRANTY) -FRONT DRIVE SHAFT BAD - REPLACED AT 75,000 MILES (OUT OF WARRANTY) -RACK AND PINION BAD 86,000 MILES (NEEDS REPLACED) NISSAN REFUSED TO COVER…

Read full complaint

2005 NISSAN TITAN LE, 86,800 MILES CURRENT -REAR AXLE SEALS LEAK - REPLACED AT 62,000 MILES (OUT OF WARRANTY) -REAR DRIVE SHAFT CRACKED - REPLACED AT 62,000 MILES (OUT OF WARRANTY) -FRONT DRIVE SHAFT BAD - REPLACED AT 75,000 MILES (OUT OF WARRANTY) -RACK AND PINION BAD 86,000 MILES (NEEDS REPLACED) NISSAN REFUSED TO COVER ANY OF THESE REPAIRS, EVEN THOUGH THEY WERE SAFETY RELATED AND SHOULD NOT HAVE OCCURRED UNDER 150,000 MILES. THIS VEHICLE IS NOT USED OFF ROAD - ALL HIGHWAY AND CITY DRIVING. *TR

NHTSA ODI #10252620

29,995 miles · Aug 3, 2007
Power TrainSteering

NORMAL DRIVING. TWO LEFT REAR AXLE SEAL LEAKS THAT LEAKED SO BAD THE BRAKES HAVE FAILED. POWER STEERING PUMP LINE LEAKED OUT ALL THE POWER STEERING FLUID. FAILED RACK AND PINION STEERING. *JB

NHTSA ODI #10198464

Official recalls

4

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.