OWN A 2005 NISSAN TITAN 5.6 LE 4X4 OFFROAD AND TOW PACKAGE. ON 5/29/07, I WAS PULLING MY TRAVEL TRAILER AND MADE A TURN, THE REAR END MADE A LOUD AND TRUCK SHUDDERING THUMP. AFTERWARDS, EVERYTIME I ACCELERATED OR TURNED, THE REAR END WOULD THUMP AND SHAKE THE ENTIRE TRUCK. I TOOK IT TO A DEALER AND WAS TOLD THE REAR END NEEDE…
Read full complaint
OWN A 2005 NISSAN TITAN 5.6 LE 4X4 OFFROAD AND TOW PACKAGE. ON 5/29/07, I WAS PULLING MY TRAVEL TRAILER AND MADE A TURN, THE REAR END MADE A LOUD AND TRUCK SHUDDERING THUMP. AFTERWARDS, EVERYTIME I ACCELERATED OR TURNED, THE REAR END WOULD THUMP AND SHAKE THE ENTIRE TRUCK. I TOOK IT TO A DEALER AND WAS TOLD THE REAR END NEEDED TO BE REPLACED. THIS WAS A KNOWN ISSUE. I WAS IN RICHMOND, VA BUT LIVE IN NJ, SO I DECIDED TO TRY TO GET IT HOME. PUT IT IN 4X4 HI MODE AND MADE IT. DROPPED IT OFF TO NISSAN DEALER IN NJ, THEY ARE REPLACING THE REAR END NOW, UNDER POWERTRAIN WARRANTY. *TR
NHTSA ODI #10192197
80,000 miles · May 31, 2007
Power TrainStructure
I BOUGHT A NISSAN TITAN [2005].NEW. I HAVE 86,000 MILES, OUT OF WARRANTY AND THE RIGHT REAR SEALS HAS STARTED TO LEAK. DEALER WANT FIX IT AS A FACTORY DEFECT, ALSO THE RIGHT TIRE STICKS OUT MORE THAN THE LEFT. I NEED HELP PROVING IT'S TOTALLY FACTORY PROBLEM. *TR
NHTSA ODI #10192173
80,000 miles · May 24, 2007
Power Train
DURING THE MOST RECENT OIL CHANGE, I WAS DIRECTED BY THE TECHNICIAN TO THE BACK SIDE OF THE REAR WHEELS, BOTH SIDES. FROM THIS VANTAGE POINT, YOU CAN EASILY SEE THAT LUBRICATION FROM THE REAR AXLE IS LEAKING ONTO THE REAR BRAKE ROTOR ASSEMBLY VIA THE AXLE END SEALS. I IMMEDIATLEY CONTACTED NISSANUSA AND HAVE BEEN ATTEMPTING TO…
Read full complaint
DURING THE MOST RECENT OIL CHANGE, I WAS DIRECTED BY THE TECHNICIAN TO THE BACK SIDE OF THE REAR WHEELS, BOTH SIDES. FROM THIS VANTAGE POINT, YOU CAN EASILY SEE THAT LUBRICATION FROM THE REAR AXLE IS LEAKING ONTO THE REAR BRAKE ROTOR ASSEMBLY VIA THE AXLE END SEALS. I IMMEDIATLEY CONTACTED NISSANUSA AND HAVE BEEN ATTEMPTING TO GET ANSWERS FROM THEM AS TO WHAT, IF ANYTHING THEY WILL DO TO RECTIFY THIS CONDITION. MY EXTENDED SERVICE PLAN HAS RECENTLY EXPIRED. ACCORDING TO INTERNET FORUMS FOR NISSAN TITANS, THERE HAVE BEEN NUMEROUS PROBLEMS WITH THIS AND IT APPEARS TO BE A SAFETY HAZARD. NISSANUSA CONTINUES TO GIVE ME THE RUN AROUND BY AVOIDING ANY DIALOGUE.
NHTSA ODI #10191664
13,382 miles · May 18, 2007
Power Train
REAR DIFFERENTIAL BROKE WHILE ACCELERATING INTO HEAVY TRAFFIC ,LEAVING THE VEHICLE POWERLESS. *AK
NHTSA ODI #10191158
80,000 miles · May 16, 2007
Power Train
DURING A RECENT OIL CHANGE, THE TECHNICIAN POINTED OUT THE AXLE END SEALS WERE LEAKING ONTO THE REAR BRAKE ROTOR ASSEMBLY ON MY SE KING CAB. THIS REDUCES THE BRAKE'S ABILITY TO STOP. I CURRENTLY HAVE 81,000 MILES ON THIS 2005 MODEL. MY EXTENDED WARRANTY RAN OUT AT 75,000 MILES JUST ABOUT 6 WEEKS AGO AND THIS PROBLEM WAS PROB…
Read full complaint
DURING A RECENT OIL CHANGE, THE TECHNICIAN POINTED OUT THE AXLE END SEALS WERE LEAKING ONTO THE REAR BRAKE ROTOR ASSEMBLY ON MY SE KING CAB. THIS REDUCES THE BRAKE'S ABILITY TO STOP. I CURRENTLY HAVE 81,000 MILES ON THIS 2005 MODEL. MY EXTENDED WARRANTY RAN OUT AT 75,000 MILES JUST ABOUT 6 WEEKS AGO AND THIS PROBLEM WAS PROBABLY HAPPENING DURING THE WARRANTY BUT I DIDN'T NOTICE IT AS I CHANGE MY OWN OIL MYSELF MOST OF THE TIME. AFTER LOOKING OVER THE INTERNET, I HAVE FOUND THAT THIS IS A COMMON PROBLEM AMONG THE TITANS. NISSAN SHOULD ADDRESS THIS PROBLEM AS THEY DID THE BRAKE PROBLEM. *AK
NHTSA ODI #10190880
Mileage unknown · May 8, 2007
Power Train
REAR AXLE SEAL FAILED, CAUSING DIFFERENTIAL FLUID LEAK AT RIGHT REAR HUB. CAUSED LOW LEVEL OF FLUID IN DIFFERENTIAL. ENTIRE AXLE ASSEMBLY BEING REPLACED.*AK
NHTSA ODI #10190144
43,000 miles · May 2, 2007
Power Train
WE OWN A TITAN AND ARE SATISFIED BUT HAD SOME ISSUES AS CAN BE EXPECTED WITH A NEWLY DESIGNED VEHICLE. EACH HAS BEEN TAKEN CARE OF UNDER WARRANTY FROM OUR DEALER ALAN JAY OF SEBRING FLORIDA, A VERY PROFESSIONAL OPERATION I MIGHT ADD. THE ONE MOST RECENT OF CONCERN CAUSED BRAKE INTERRUPTION AND WHEN I INSPECTED THE BRAKE SYSTEM O…
Read full complaint
WE OWN A TITAN AND ARE SATISFIED BUT HAD SOME ISSUES AS CAN BE EXPECTED WITH A NEWLY DESIGNED VEHICLE. EACH HAS BEEN TAKEN CARE OF UNDER WARRANTY FROM OUR DEALER ALAN JAY OF SEBRING FLORIDA, A VERY PROFESSIONAL OPERATION I MIGHT ADD. THE ONE MOST RECENT OF CONCERN CAUSED BRAKE INTERRUPTION AND WHEN I INSPECTED THE BRAKE SYSTEM ONE OF THE REAR BRAKES APPEARED TO BE LEAKING, WHICH I SUSPECTED THAT TO BE THE PROBLEM. THE DEALER DETERMINED THAT IT WAS A REAR AXLE SEAL AND REPLACED BOTH THE SEAL AND THE BEARING WHICH HAD BECOME DAMAGED. AFTER CHECKING THE INTERNET I HAVE FOUND THIS TO BE A QUITE COMMON PROBLEM THAT HAS BEEN OVERLOOKED. WE USE THIS VEHICLE DAILY FOR BUSINESS AND ALREADY HAVE 44,000 MILES ON IT AND IT IS NOT YET TWO YEARS OLD. MY CONCERN IS MY WARRANTY WILL RUN OUT WITH EXCEEDED MILES BRFORE THE TIME LIMIT AND THE OTHER AXLE CAN HAVE THE SAME PROBLEM. WHY DID THEY ONLY CHANGE ONE? I WOULD LIKE THE OTHER SIDE CHANGED AS THEY ARE IDENTICAL IN DESIGN. PLEASE RESPOND TO MY REQUEST, THIS CAN BE DANGEROUS SITUATION. *TR
NHTSA ODI #10189522
47,000 miles · Apr 17, 2007
Power Train
REAR AXLES SEAL FAILURES ON A 2005 NISSAN TITAN. *AK
NHTSA ODI #10188087
22,600 miles · Apr 4, 2007
Power Train
REAR DIFFERENTIAL FAILURE AT 22,600 MILES.*AK
NHTSA ODI #10186997
30,000 miles · Mar 27, 2007
Power Train
I STARTED MY TRUCK, PUT IN GEAR AND IT MADE A VERY UGLY NOISE IN THE REAR. I TRIED DRIVE AND REVERSE AND IT DID THE SAME THING IN BOTH GEARS. I CALLED NISSAN, HAD THEM TOW IT AND THEY ENDED UP REPLACING THE ENTIRE REAR END. I ONLY HAD 30K ON MY TRUCK WITH MOSTLY HIGHWAY MILES.*JB
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
2005 Nissan Titan Problems, Complaints & Recalls | Skip That Year