← New search

2005 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2005 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

800 reports with mileage · 91 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 469 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 68 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

11 crash reports7 fire reports10 injury reports

Power Train complaints

469 reports
Clear category filter
149,000 miles · Apr 8, 2015
Power Train

WHEN I PUT VEHICLE IN DRIVE, IT WOULD ONLY GO IN REVERSE. I DISCOVERED THE LINKAGE FROM THE GEARSHIFT LEVER TO THE CABLE HAD SEPARATED. THE PLASTIC RETAINING RING ON THE SHIFT CABLE HAD BROKEN TO PIECES AND LEFT NOTHING TO HOLD THE CABLE TO THE SHIFT LEVER. THIS IS POTENTIALLY EXTREMELY DANGEROUS AS A DRIVER COULD MOVE LEVER …

Read full complaint

WHEN I PUT VEHICLE IN DRIVE, IT WOULD ONLY GO IN REVERSE. I DISCOVERED THE LINKAGE FROM THE GEARSHIFT LEVER TO THE CABLE HAD SEPARATED. THE PLASTIC RETAINING RING ON THE SHIFT CABLE HAD BROKEN TO PIECES AND LEFT NOTHING TO HOLD THE CABLE TO THE SHIFT LEVER. THIS IS POTENTIALLY EXTREMELY DANGEROUS AS A DRIVER COULD MOVE LEVER TO PARK AND THINK HE IS ACTUALLY IN PARK WHEN THE TRANSMISSION IS ENGAGED. SOMEONE GETTING OUT OF THE VEHICLE WHILE IT IS STILL RUNNING WILL THEN HAVE A RUNAWAY VEHICLE. LOCAL NISSAN DEALER HAD NO REPLACEMENT PART. I INSTALLED A RETAINING RING AND CLIP. THE FIX COSTS PENNIES AND JUST A FEW MINUTES TIME. *TR

NHTSA ODI #10704396

107,426 miles · Mar 20, 2015
Power Train

AS I WAS REVERSING TO BACK OUT A PARKING SPOT I FELT A HARD THUD LOOKED UNDER AND AROUND TRUCK DIDN'T SEE ANYTHING IT STARTED SNOWING AND I HAD TO USE MY 4WHEEL DRIVE AND IT WOULD NOT ENGAGE THE INDICATOR SAID IT WAS IN 4WHEEL DRIVE BUT THE FRONT WHEELS WOULD NOT TURN TOOK IT A TRANSMISSION SHOP THEY TOLD ME MY LEFT FRONT AXLE P…

Read full complaint

AS I WAS REVERSING TO BACK OUT A PARKING SPOT I FELT A HARD THUD LOOKED UNDER AND AROUND TRUCK DIDN'T SEE ANYTHING IT STARTED SNOWING AND I HAD TO USE MY 4WHEEL DRIVE AND IT WOULD NOT ENGAGE THE INDICATOR SAID IT WAS IN 4WHEEL DRIVE BUT THE FRONT WHEELS WOULD NOT TURN TOOK IT A TRANSMISSION SHOP THEY TOLD ME MY LEFT FRONT AXLE POPPED OUT OF THE DIFFERENTIAL WHICH IS A COMMON PROBLEM WITH THE TITAN I FOUND SEVERAL COMPLAINTS ABOUT THIS AND THE SAME WAY MY TRUCK AXLE POPPED OUT AND SAME SIDE CALLED NISSAN AND THEY WONT FIX THIS PROBLEM ITS VERY COSTLY AND DANGEROUS SOME PEOPLE FRONT DIFF BLEW APART I THINK SOMETHING NEEDS TO BE DONE A RECALL OR SOMETHING IT CAN CAUSE A ACCIDENT. *TR

NHTSA ODI #10695541

80,000 miles · Mar 10, 2015
Power Train

THIS IS THE SECOND DIFFERENTIAL PUT INTO TRUCK SINCE JULY 2014. THE FIRST ONE WAS WITHIN 30 DAYS OF PURCHASE AT 65,000 AND THE SECOND ONE AT 80,000 COSTING $3800.00. THE TRUCK IS BACK IN FOR REPAIR WITHIN 5 DAYS SINCE AND BACK BRAKES ARE NOT WORKING PROPERLY. WAITING TO HEAR FROM MECHANIC. *TR

NHTSA ODI #10693224

85,000 miles · Mar 4, 2015
Power Train

I HAVE A 2005 NISSAN TITAN WHICH I PURCHASED USED AT 23,000 MILES. TWO YEARS AGO (2013) I HEARD A LOUD NOISE COMING FROM THE FRONT DIFFERENTIAL. I TOOK IT TO A MECHANIC AND I WAS TOLD THAT THE U-JOINTS FAILED WHICH COST $1400 DOLLARS. NOW, MARCH 2015, I AGAIN HEARD A LOUD NOISE COMING FROM THE FRONT DIFFERENTIAL. I FOUND THAT…

Read full complaint

I HAVE A 2005 NISSAN TITAN WHICH I PURCHASED USED AT 23,000 MILES. TWO YEARS AGO (2013) I HEARD A LOUD NOISE COMING FROM THE FRONT DIFFERENTIAL. I TOOK IT TO A MECHANIC AND I WAS TOLD THAT THE U-JOINTS FAILED WHICH COST $1400 DOLLARS. NOW, MARCH 2015, I AGAIN HEARD A LOUD NOISE COMING FROM THE FRONT DIFFERENTIAL. I FOUND THAT THE RIGHT AXLE HAD POPPED OUT. I TOOK IT TO A MECHANIC AND I WAS TOLD THAT THE FRONT DIFFERENTIAL FAILED WHICH COST $2300 DOLLARS. I WAS TOLD BY MY MECHANIC THAT BOTH OF THESE INCIDENTS COULD HAVE CAUSED ME TO CRASH AND THAT I WAS LUCKY. I HAVE HAD SEVERAL OTHER ISSUES WITH THIS VEHICLE (FUEL PUMP, BRAKES, EXHAUST SYSTEM). I WAS ALSO CONTACTED BY AN ATTORNEY WHO INFORMED ME THAT HE WAS CONDUCTING A LAW SUITE AND WANTED TO KNOW WHAT ISSUES I HAVE HAD. THE ATTORNEY INFORMED ME THAT MY VEHICLE WAS DEEMED A "LEMON" BY THE FIRST OWNER. *TR

NHTSA ODI #10692079

62,129 miles · Feb 20, 2015
Power TrainInjury

WHILE PULLING OUR BOAT OUT FROM BOAT RAMP IN 4LO AND A LOUD NOISE CAME FROM DIFF. WHEN I ARRIVE HOME 25MIN LATER IN THE DRIVE WAY I NOTICED GEAR OIL FROM PASSENGER SIDE. UNDER TRUCK I NOTICED WHERE LEAK WAS COMING FROM AND PUSHED THE AXLE BACK AND IT STOPPED LEAKING. I DRAINED AND REMOVED SHAFT ASSEMBLY SIDE DIFF AND REPLACE SEA…

Read full complaint

WHILE PULLING OUR BOAT OUT FROM BOAT RAMP IN 4LO AND A LOUD NOISE CAME FROM DIFF. WHEN I ARRIVE HOME 25MIN LATER IN THE DRIVE WAY I NOTICED GEAR OIL FROM PASSENGER SIDE. UNDER TRUCK I NOTICED WHERE LEAK WAS COMING FROM AND PUSHED THE AXLE BACK AND IT STOPPED LEAKING. I DRAINED AND REMOVED SHAFT ASSEMBLY SIDE DIFF AND REPLACE SEAL AND REFILLED GEAR OIL. ON THE NEXT TRIP WE NOTICED GEAR OIL LEAK CAME HOME DID RESEARCH AND NOTICED THIS IS KNOWN PROBLEM PURCHASED THE CIRCLIP THINKING THAT WAS THE PROBLEM BUT AFTER LAST NIGHT NOTICED THE SHAFT BROKE WHERE THE CIRCLIP WAS SUPPOSE TO BE. LOOKED DOWN THE DIFF HOUSING AND NOTICED THE OTHER PIECE OF THE SHAFT NUB STUCK INSIDE. ESTIMATE $2500 FOR DIFF REPLACEMENT TO 38500-8S112B OR $825 TO REPLACE SHAFT AND GEAR. 3RD TIME I'VE EVER USED 4 WHEEL DRIVE!!!! *TR

NHTSA ODI #10689642

Mileage unknown · Jan 5, 2015
Power Train

WHILE TRAVELING AT APPROXIMATELY 70 MPH ON A US HIGHWAY, THE VEHICLE BEGAN TO VIGOROUSLY SHAKE AND A LOUD CLANKING NOISE BEGAN FROM THE REAR OF THE VEHICLE. SUDDENLY THERE WAS A LOUD BANGING NOISE COMING FROM UNDERNEATH THE VEHICLE. UPON EXITING THE VEHICLE AS IT CAME TO A STOP, I NOTICED THAT THE REAR DRIVE SHAFT HAD FALLEN OF…

Read full complaint

WHILE TRAVELING AT APPROXIMATELY 70 MPH ON A US HIGHWAY, THE VEHICLE BEGAN TO VIGOROUSLY SHAKE AND A LOUD CLANKING NOISE BEGAN FROM THE REAR OF THE VEHICLE. SUDDENLY THERE WAS A LOUD BANGING NOISE COMING FROM UNDERNEATH THE VEHICLE. UPON EXITING THE VEHICLE AS IT CAME TO A STOP, I NOTICED THAT THE REAR DRIVE SHAFT HAD FALLEN OFF. WHEN ATTEMPTING TO LOAD THE VEHICLE ON A WRECKER, THE REAR WHEELS WOULDN'T ROLL. THE ENTIRE REAR DIFFERENTIAL AND AXLE HAD SEIZED. *TR

NHTSA ODI #10670273

145,000 miles · Dec 25, 2014
Power Train

REAR SEAL COMPLETELY FAILED WHILE DRIVING CAUSING DIFFERENTIAL OIL TO SATURATE THE REAR BRAKES. *TR

NHTSA ODI #10668253

69,500 miles · Dec 8, 2014
Power Train

FRONT AXLE POPPED OUT, CAUSING FLUIDS TO DRAIN. DIFFERENTIAL FAILURE. *TR

NHTSA ODI #10662760

156,000 miles · Nov 19, 2014
Power Train

THIS IS A COMMON ISSUE WHICH IT DOCUMENTED ON MANY ONLINE NISSAN TITAN / ARMADA FORUMS. THE FRONT AXLE HAS SEPARATED FROM THE DIFFERENTIAL HOUSING CAUSING LOSS OF GEAR FLUID AND LACK OF DRIVEABILITY. *TR

NHTSA ODI #10659249

70,500 miles · Nov 7, 2014
Power Train

FRONT DIFFERENTIAL HAS FAILED, SEVER CRACKING IN THE HOUSING. LOUD WHINE/GRUMBLE IS HEARD WHEN IN BOTH TWO WHEEL DRIVE AND FOUR WHEEL DRIVE. ALL LUBRICANTS HAVE BEEN SERVICED UNDER MANUFACTURE RECOMMENDATIONS. AFTER REVIEWING ONLINE, I SEE THIS HAS BEEN A COMMON PROBLEM FOR NISSAN TITANS. *TR

NHTSA ODI #10653512

Official recalls

4

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.