← New search

2011 Mazda MAZDA3

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2011 Mazda MAZDA3 do not stand out strongly from the model-year median of 108.

About this comparison →

When problems were reported

Mileage at the reported incident

95 reports with mileage · 37 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Seats. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

12 crash reports2 fire reports8 injury reports

What owners actually said

132 reports
100,000 miles · May 1, 2017
Seats

LIFTER ON DRIVER SEAT BROKE AT THE WELD, DEALERSHIP'S REASON IS WEAR AND TEAR ON A NON MECHANICAL YET WELDED PART. THIS PROBLEM IS A SAFETY ISSUE WHILE DRIVING AS THE SEAT IS NOT STABLE NOR SAFE TO DRIVE.

NHTSA ODI #10981745

66,000 miles · Apr 28, 2017
Steering

WHILE DRIVING THE VEHICLE ON CITY STREETS AND HIGHWAY THE POWER STEERING STOPPED FUNCTIONING. CAUSING THE VEHICLE TO BE MANUEL STEERING. A LESS EXPIERIANCED DRIVER WAS OPPERATING THE VEHICLE AT THE TIME. HAD HIM TURN THE CAR OFF WAIT A SHORT TIME AND START THE CAR. POWER STEERING WAS BACK. PROBLEM PERSISTED AND THE CAR IS IN FO…

Read full complaint

WHILE DRIVING THE VEHICLE ON CITY STREETS AND HIGHWAY THE POWER STEERING STOPPED FUNCTIONING. CAUSING THE VEHICLE TO BE MANUEL STEERING. A LESS EXPIERIANCED DRIVER WAS OPPERATING THE VEHICLE AT THE TIME. HAD HIM TURN THE CAR OFF WAIT A SHORT TIME AND START THE CAR. POWER STEERING WAS BACK. PROBLEM PERSISTED AND THE CAR IS IN FOR REPAIR. I ALSO SEE STEERING PROBLEM RECALLS ON THE 2008-2009 MODELS.

NHTSA ODI #10981183

44,600 miles · Feb 18, 2017
Seats

WOBBLY DRIVERS SEAT. CLUNKY SOUND WHEN TRUING. SOME TIMES MOVES ON TRACK BY ITSELF.PERSISTENT PROBLEM SINCE DAY OF PURCHASE.

NHTSA ODI #10955452

55,000 miles · Feb 13, 2017
Seats

SEAT TRACK-OCCUPANT SENSOR RIGHT BCN167SW0A LIGHT FLASHES ON DASHBOARD WHEN CAR IS TURNED ON. IT WAS PREVIOUSLY REPLACED IN 2012. MAZDA WARRANTY DOESN'T COVER THIS ANY LONGER, BUT IT SHOULD. I BELIEVE MAZDA HAS A LEGAL OBLIGATION TO FIX THIS PROBLEM AT NO COST BECAUSE THIS IS THE SECOND TIME IT HAS HAPPENED IN FIVE YEARS.

NHTSA ODI #10954366

Mileage unknown · Jan 26, 2017
Structure

TL* THE CONTACT OWNS A 2011 MAZDA 3. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE); HOWEVER, THE PART FOR THE RECALL REPAIR WAS UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE CONTACT HAD NOT EXPERIENCED A FAILURE. THE MANUF…

Read full complaint

TL* THE CONTACT OWNS A 2011 MAZDA 3. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE); HOWEVER, THE PART FOR THE RECALL REPAIR WAS UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE CONTACT HAD NOT EXPERIENCED A FAILURE. THE MANUFACTURER WAS MADE AWARE OF THE ISSUE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #10947815

68,000 miles · Dec 5, 2016
Structure

HOOD LATCH STRIKER RUSTS AT ITS WELDING POINT. IF IT SEPARATES FROM THE HOOD, FOLLOWING MAY OCCUR DURING VEHICLE MOVEMENT: 1. HOOD OPENS AND IMPACTS DRIVER FRONT VISIBILITY 2. HOOD BRAKES THE WINDSHIELD AND POTENTIALLY INJURES THE DRIVER 3. HOOD SEPARATES FROM THE VEHICLE AND IMPACTS OTHER DRIVERS (BEHIND)

NHTSA ODI #10930093

29,000 miles · Nov 1, 2016
Exterior LightingStructure

TL* THE CONTACT OWNS A 2011 MAZDA 3. WHILE THE VEHICLE WAS PARKED, THE CONTACT NOTICED WATER IN THE PASSENGER SIDE HEAD LAMP. AS A RESULT, THE HEAD LAMP FAILED TO ILLUMINATE. THE DEALER DIAGNOSED THAT THE HEAD LAMP NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE VIN WAS ALSO INCLUDED IN NHTSA CAMPAIGN NUMBER: 16V644000 …

Read full complaint

TL* THE CONTACT OWNS A 2011 MAZDA 3. WHILE THE VEHICLE WAS PARKED, THE CONTACT NOTICED WATER IN THE PASSENGER SIDE HEAD LAMP. AS A RESULT, THE HEAD LAMP FAILED TO ILLUMINATE. THE DEALER DIAGNOSED THAT THE HEAD LAMP NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE VIN WAS ALSO INCLUDED IN NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE). THE PART NEEDED TO REPAIR THE VEHICLE WAS UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS 29,000. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #10920456

Mileage unknown · Oct 15, 2016
Unknown Or Other

THE VEHICLE HAS UNINTENDED SURGES IN ACCELERATION DURING DRIVING OR BACKING OUT THE DRIVE. WAS TOLD TO SERVICE DEPARTMENT AT LOCAL DEALERSHIP DURING ROUTINE MAINTENANCE; I WAS TOLD THAT THEY COULD FIND NOTHING. THERE HAS BEEN NO ACCIDENT FROM THIS AS OF YET. THIS HAS BEEN ONGOING SINCE THE DATE OF PURCHASE. AT FIRST, I THOUGHT …

Read full complaint

THE VEHICLE HAS UNINTENDED SURGES IN ACCELERATION DURING DRIVING OR BACKING OUT THE DRIVE. WAS TOLD TO SERVICE DEPARTMENT AT LOCAL DEALERSHIP DURING ROUTINE MAINTENANCE; I WAS TOLD THAT THEY COULD FIND NOTHING. THERE HAS BEEN NO ACCIDENT FROM THIS AS OF YET. THIS HAS BEEN ONGOING SINCE THE DATE OF PURCHASE. AT FIRST, I THOUGHT I WAS UNUSED TO THE ACCELERATOR. ALSO, THE HEADLIGHTS ON THIS VEHICLE ARE FOGGED FROM THE INSIDE (WATER UNDER THE HEADLIGHTS) THIS RESULTS IN THE LIGHT BEAM NOT BEING STRONG ENOUGH AT NIGHT TO BE AS VISIBLE AS SHOULD BE TO OTHERS OR MYSELF.

NHTSA ODI #10916223

60,000 miles · Oct 7, 2016
Electrical SystemExterior LightingStructure

PASSENGER HEADLAMP GETTING EXCESSIVE CONDENSTATION BUILD UP AFTER CAR WASH OR RAIN STORM EVENTUALLY CAUSES HID BULB AND BALLAST FAILURE DUE TO SHORT CAUSED BY WATER INGRESS. HOUSING HAS BEEN CHANGED AND STILL LEAKS IN ALMOST EXACT SAME PATTERN AS OLD HOUSING. THIS IS A SAFETY DEFECT AS IT AFFECTS MY ABILITY TO SAFELY, AND LEGALL…

Read full complaint

PASSENGER HEADLAMP GETTING EXCESSIVE CONDENSTATION BUILD UP AFTER CAR WASH OR RAIN STORM EVENTUALLY CAUSES HID BULB AND BALLAST FAILURE DUE TO SHORT CAUSED BY WATER INGRESS. HOUSING HAS BEEN CHANGED AND STILL LEAKS IN ALMOST EXACT SAME PATTERN AS OLD HOUSING. THIS IS A SAFETY DEFECT AS IT AFFECTS MY ABILITY TO SAFELY, AND LEGALLY DRIVE MY CAR IN LOW OR NO LIGHT CONDITIONS AND COULD CAUSE AN ACCIDENT.

NHTSA ODI #10914541

65,000 miles · Jul 31, 2016
Unknown Or Other

THE DASHBOARD IS SEPARATING AT THE TOP OF THE INFO SCREEN.

NHTSA ODI #10891954

Official recalls

2

17V082000 · Seats

Feb 9, 2017

Mazda North American Operations (Mazda) is recalling certain 2011 Mazda2 and 2010-2011 Mazda3 and Mazdaspeed3 vehicles equipped with a manual seat lifter. In the affected vehicles, the seat height adjustment lifter links may break or detach from the seat frame and the seat angle may incline causing the driver to not be able to maintain an appropriate driving position.

Consequence & remedy

Consequence: If the driver cannot maintain an appropriate driving position, there is an increased risk of a crash.

Remedy: Mazda will notify owners, and dealers will inspect the seat lifter links and install a reinforcement bracket to the lifter links, or replace the entire seat adjuster unit, free of charge. The recall began April 7, 2017. Owners may contact Mazda customer service at 1-800-222-5500. Mazda's number for this recall is 0917B.

16V644000 · Structure:body:hatchback/liftgate

Sep 6, 2016

Mazda North American Operations (Mazda) is recalling certain model year 2010-2013 Mazda3 and Mazdaspeed3 vehicles manufactured November 18, 2008, to June 8, 2013, 2012-2015 Mazda5 vehicles manufactured October 26, 2010, to June 22, 2015, 2016 CX-3 vehicles manufactured June 1, 2015, to December 26, 2015, and 2013-2016 CX-5 vehicles manufactured December 15, 2011, to December 26, 2015. On the affected vehicles, the lift gate support struts may corrode, possibly causing the struts to break and/or the lift gate to drop unexpectedly.

Consequence & remedy

Consequence: If the lift gate falls unexpectedly, it may hit the user, increasing their risk of injury.

Remedy: Mazda dealers will replace the both lift gate supports, free of charge, however parts are not currently available. The recall began April 2017. Owners may contact Mazda customer service at 1-800-222-5500. Mazda's number for this recall is 9916H.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.