Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
250–25K
2625–50K
1550–75K
1075–100K
14100–150K
5150K+
95 reports with mileage · 37 unknown
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
Air Bags. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Seats. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Electrical System. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
12 crash reports2 fire reports8 injury reports
What owners actually said
132 reports
85,000 miles · Aug 24, 2017
Air BagsCrash
TAKATA AIRBAG: ON 12/25/16 SUNDAY MY VEHICLE SUSTAINED MAJOR DAMAGE IN A HIT AND RUN, MY AIRBAG (DRIVER SIDE) DID NOT DEPLOY. MY VEHICLE WAS HIT SO HARD I WAS KNOCK INTO A 360 SPIN. (INSURANCE PROVIDER: PROGRESSIVE POLICY #[XXX], DETROIT POLICE REPORT #[XXX]) I WAS IN MOTION ENTERING THE INTERSECTION ON A CITY STREET, DRY ROAD C…
Read full complaint
TAKATA AIRBAG: ON 12/25/16 SUNDAY MY VEHICLE SUSTAINED MAJOR DAMAGE IN A HIT AND RUN, MY AIRBAG (DRIVER SIDE) DID NOT DEPLOY. MY VEHICLE WAS HIT SO HARD I WAS KNOCK INTO A 360 SPIN. (INSURANCE PROVIDER: PROGRESSIVE POLICY #[XXX], DETROIT POLICE REPORT #[XXX]) I WAS IN MOTION ENTERING THE INTERSECTION ON A CITY STREET, DRY ROAD CONDITION. I DID NOT GO TO THE HOSPITAL I USED WORK SICK DAY SINCE I WAS ON MY WAY TO WORK (POLICE OFFICER) (EMAIL: [XXX]. INFORMATION Redacted PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6).
NHTSA ODI #11019397
45,304 miles · Aug 14, 2017
Tires
AN APPROXIMATELY 2 YEAR OLD OHTSU TIRE STARTED TO SEPARATE WHILE DRIVING AROUND 70 MILES AN HOUR.
NHTSA ODI #11015060
77,745 miles · Aug 13, 2017
Steering
MY CLUTCH BLEW ON 2/7/17 WHILE I WAS DRIVING ON A MULTILANE BUSY CITY STREET. ALL FUNCTION OF THE MANUAL TRANSMISSION CEASED AS I WAS DRIVING, AND I COASTED ACROSS A LANE AND TO THE SIDE OF THE ROAD. I AM THANKFUL THAT I DID NOT GET HURT. HOWEVER, I AM VERY CONCERNED THAT MY CAR, A 2011 MAZDA3, STOPPED WORKING WHILE I WAS DRI…
Read full complaint
MY CLUTCH BLEW ON 2/7/17 WHILE I WAS DRIVING ON A MULTILANE BUSY CITY STREET. ALL FUNCTION OF THE MANUAL TRANSMISSION CEASED AS I WAS DRIVING, AND I COASTED ACROSS A LANE AND TO THE SIDE OF THE ROAD. I AM THANKFUL THAT I DID NOT GET HURT. HOWEVER, I AM VERY CONCERNED THAT MY CAR, A 2011 MAZDA3, STOPPED WORKING WHILE I WAS DRIVING! THIS DIRECTLY PUT MY LIFE IN DANGER! I AM AWARE THAT MAZDA HAS A KNOWN CLUTCH RELEASE ASSEMBLY DEFECT - "A SIGNIFICANT SAFETY RISK TO THE DRIVER AND PASSENGERS AS OFTEN, SUDDENLY AND WITHOUT WARNING, THE VEHICLE'S ENGINE IS UNABLE TO PROVIDE POWER TO THE TRANSMISSION AND BECOMES INOPERABLE.' (HTTPS://TOPCLASSACTIONS.COM/LAWSUIT-SETTLEMENTS/LAWSUIT-NEWS/333511-MAZDA-CLASS-ACTION-SAYS-AUTOMAKER-HID-CLUTCH-DEFECT-DECADE/).
NHTSA ODI #11014909
Mileage unknown · Aug 11, 2017
Air BagsSeat Belts
PASSENGER SEAT BELT SAYS PASSENGER AIR BAG OFF WHEN HOOKED UP. IT STAYS OFF WHEN PASSENGER SITS IN IT.
NHTSA ODI #11014762
Mileage unknown · Aug 10, 2017
Structure
TL* THE CONTACT OWNS A 2011 MAZDA MAZDA3. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE) HOWEVER, THE PART TO DO THE REPAIR WAS UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. ANDERSON FORD OF ANDERSON, SOUTH CAROLINA WAS CONTAC…
Read full complaint
TL* THE CONTACT OWNS A 2011 MAZDA MAZDA3. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE) HOWEVER, THE PART TO DO THE REPAIR WAS UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. ANDERSON FORD OF ANDERSON, SOUTH CAROLINA WAS CONTACTED ABOUT THE RECALL AND STATED THAT THE PARTS WERE UNAVAILABLE. THE MANUFACTURER WAS NOT MADE AWARE OF THE ISSUE. THE CONTACT HAD NOT EXPERIENCED A FAILURE. PART DISTRIBUTION DISCONNECT. UPDATED 10/17/17*LJ UPDATED 10/4/18*JB
NHTSA ODI #11014208
Mileage unknown · Aug 9, 2017
Air Bags
"TAKATA RECALL" - I RECEIVED IN THE MAIL A LETTER ABOUT THE AIRBAG RECALL AND I NEED A CLEAR EXPLAINATION AS TO WHY THERE IS NO RECALL FOR MY VEHICLE, WHICH BY THE WAY BOTH AIRBAG WARNING LIGHTS ARE ON(DRIVER SIDE & PASSENGER SIDE), BUT YET I RECEIVED A LETTER TO PARTICIPATE IN A CLASS ACTION LAWSUIT. EXPLAIN?
NHTSA ODI #11014039
Mileage unknown · Aug 7, 2017
Air BagsService Brakes
SOMETIMES TURNS ON THE LIGHT OF ACTIVATED AIRBAGS AND EVEN IF THE EMERGENCY LEVER IS FULLY RAISED, THE CARRAIGE MOVES AS IF IT WERE DOWN.
NHTSA ODI #11013296
Mileage unknown · Jul 24, 2017
Seats
TL* THE CONTACT OWNS A 2011 MAZDA 3. THE CONTACT STATED THAT THE RECALL NOTICE FOR NHTSA CAMPAIGN NUMBER: 17V082000 (SEATS) WAS RECEIVED IN MARCH OF 2017. AFTER CONTACTING THE DEALER (SANTA MARIA MAZDA IN SANTA MARIA, CALIFORNIA) AND THE MANUFACTURER ON MULTIPLE OCCASIONS, THE CONTACT WAS INFORMED THAT THE PARTS NEEDED FOR THE R…
Read full complaint
TL* THE CONTACT OWNS A 2011 MAZDA 3. THE CONTACT STATED THAT THE RECALL NOTICE FOR NHTSA CAMPAIGN NUMBER: 17V082000 (SEATS) WAS RECEIVED IN MARCH OF 2017. AFTER CONTACTING THE DEALER (SANTA MARIA MAZDA IN SANTA MARIA, CALIFORNIA) AND THE MANUFACTURER ON MULTIPLE OCCASIONS, THE CONTACT WAS INFORMED THAT THE PARTS NEEDED FOR THE RECALL REMEDY WERE STILL NOT AVAILABLE AND NO ESTIMATED TIME FOR RECEIVING THE PARTS COULD BE PROVIDED. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.
NHTSA ODI #11010338
Mileage unknown · Jun 28, 2017
Structure
TL* THE CONTACT OWNS A 2011 MAZDA 3 HATCHBACK. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE); HOWEVER, THE PART FOR THE RECALL REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE BOB KING MAZDA DEALER WAS CONTACTED A…
Read full complaint
TL* THE CONTACT OWNS A 2011 MAZDA 3 HATCHBACK. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE); HOWEVER, THE PART FOR THE RECALL REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE BOB KING MAZDA DEALER WAS CONTACTED AND STATED THAT THE PARTS WERE NOT AVAILABLE. THE MANUFACTURER WAS NOT MADE AWARE OF THE ISSUE. THE CONTACT HAD NOT EXPERIENCED A FAILURE. PARTS DISTRIBUTION DISCONNECT. UPDATED 08/22/17*LJ THE CONSUMER STATED THE VEHICLE WAS REPAIRED. *JS
NHTSA ODI #11001883
Mileage unknown · May 3, 2017
Structure
TL* THE CONTACT OWNS A 2011 MAZDA 3. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE); HOWEVER, THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CON…
Read full complaint
TL* THE CONTACT OWNS A 2011 MAZDA 3. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V644000 (STRUCTURE); HOWEVER, THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.
Mazda North American Operations (Mazda) is recalling certain 2011 Mazda2 and 2010-2011 Mazda3 and Mazdaspeed3 vehicles equipped with a manual seat lifter. In the affected vehicles, the seat height adjustment lifter links may break or detach from the seat frame and the seat angle may incline causing the driver to not be able to maintain an appropriate driving position.
Consequence & remedy
Consequence: If the driver cannot maintain an appropriate driving position, there is an increased risk of a crash.
Remedy: Mazda will notify owners, and dealers will inspect the seat lifter links and install a reinforcement bracket to the lifter links, or replace the entire seat adjuster unit, free of charge. The recall began April 7, 2017. Owners may contact Mazda customer service at 1-800-222-5500. Mazda's number for this recall is 0917B.
Mazda North American Operations (Mazda) is recalling certain model year 2010-2013 Mazda3 and Mazdaspeed3 vehicles manufactured November 18, 2008, to June 8, 2013, 2012-2015 Mazda5 vehicles manufactured October 26, 2010, to June 22, 2015, 2016 CX-3 vehicles manufactured June 1, 2015, to December 26, 2015, and 2013-2016 CX-5 vehicles manufactured December 15, 2011, to December 26, 2015. On the affected vehicles, the lift gate support struts may corrode, possibly causing the struts to break and/or the lift gate to drop unexpectedly.
Consequence & remedy
Consequence: If the lift gate falls unexpectedly, it may hit the user, increasing their risk of injury.
Remedy: Mazda dealers will replace the both lift gate supports, free of charge, however parts are not currently available. The recall began April 2017. Owners may contact Mazda customer service at 1-800-222-5500. Mazda's number for this recall is 9916H.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
EA21002 · Desiccated Air Bag Inflator Rupture
Opened Sep 17, 2021 · No close date supplied
Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Additional source detail variants (2)
Air Bags:frontal:driver Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
2011 Mazda MAZDA3 Problems, Complaints & Recalls | Skip That Year