11 reportsClear category filterMileage unknown · Apr 17, 2001
Power TrainCrash
REAR AXLE SPINDLE SEALS LEAK CAUSING GREASE TO CONTAMINATE REAR BRAKE PADS AND CAUSING LOCK UP OF REAR WHEELS AND LOSS OF CONTROL. PAID FOR UPGRADE FROM FORD GARAGE WHICH FAILED TO RESOLVE THE PROBLEM. FORD GARAGE TOLD ME THAT PROBLEM CANNOT BE FIXED. I HAVE TALKED TO SEVERAL OTHER OWNERS OF FORD TRUCKS WITH SAME REAR END AS MI…
Read full complaint
REAR AXLE SPINDLE SEALS LEAK CAUSING GREASE TO CONTAMINATE REAR BRAKE PADS AND CAUSING LOCK UP OF REAR WHEELS AND LOSS OF CONTROL. PAID FOR UPGRADE FROM FORD GARAGE WHICH FAILED TO RESOLVE THE PROBLEM. FORD GARAGE TOLD ME THAT PROBLEM CANNOT BE FIXED. I HAVE TALKED TO SEVERAL OTHER OWNERS OF FORD TRUCKS WITH SAME REAR END AS MINE AND THEY ARE HAVING THE SAME PROBLEM AS I AM. THIS IS A SAFETY ISSUE THAT SHOULD BE ADDRESSED BY FORD MOTOR COMPANY AS THESE VEHICLES ARE ON THE ROAD WAITING FOR AN ACCIDENT TO HAPPEN. AS IT IS I HAVE BEEN REPLACING SEALS AND BRAKE PADS EVERY 15,000 MILES TO AVOID A WRECK AT A COST OF 300.00 DOLLARS A REPAIR.
NHTSA ODI #744154
Mileage unknown · Jan 1, 2001
Power Train
TRANSMISSION FAILURE. *AK
NHTSA ODI #738597
Mileage unknown · Oct 27, 2000
Exterior LightingPower TrainService Brakes, Hydraulic
EQUIPPED WITH TOWING PACKAGE AXLE SEAL FAILED, AND LEAKED OIL ONTO BRAKE LINE ,CAUSING FAILURE OF BRAKES. 2. LIGHT SWITCH SHORTED OUT, BURNING ALL WIRES, AND CAUSING FIRE HAZARD.*AK
NHTSA ODI #874047
Mileage unknown · Jan 17, 2000
Power Train
TRUCK VIBRATING AT LOW SPEED. TRANSMISSION HAD TO BE REPLACED. THIS IS THE SECOND TIME THE TRANSMISSION HAD TO BE REPLACED. I NEED TO KNOW WHAT KIND OF WARRANTY RIGHTS I HAVE, BECAUSE I FEEL THAT I SHOULD NOT HAVE TO KEEP REPLACING THE TRAMISSION. PLEASE LET ME KNOW WHAT YOU FIND OUT. THANKS. *AK
NHTSA ODI #717471
Mileage unknown · Aug 26, 1997
Power Train
TORQUE CONVERTER LOCKED UP, CAUSING TRANSMISSION FAILURE. *AK
NHTSA ODI #518495
Mileage unknown · Jun 4, 1997
Power TrainService Brakes, Hydraulic
THE REAR AXLE SEALS ALLOW THE LUBRICANT TO LEAK ONTO THE BRAKES AND THE REAR BRAKES DOES NOT WORK PROPERLY. THE SEALS WERE REPLACED (4) TIMES WITHIN 70,000 MILES IN A (5) YEAR PERIOD. *AK
NHTSA ODI #812743
Mileage unknown · Oct 24, 1996
Power TrainService Brakes, Hydraulic
BOTH REAR AXLE SEALS REPLACED DUE TO IMPROPER BRAKING WHILE DRIVING DOWN MOUNTAINOUS ROAD WITHIN 20 MPH. NOT SURE IF TRUCK IS EQUIPPED W/REAR ABS BRAKES. *AK
NHTSA ODI #803976
Mileage unknown · Jul 2, 1996
Engine And Engine CoolingPower TrainStructure
TRANSMISSION PROBLEMS.
NHTSA ODI #505892
Mileage unknown · Apr 3, 1996
Power Train
TRANSMISSION FAILED. (ATTORNEY FOR CLIENT) (FOURTH VEHICLE ON 503128, 601417, 601418, 601420, 601421) *DH
NHTSA ODI #601419
Mileage unknown · Jan 25, 1996
Power Train
THE REAR AXLE SEAL HAS LEAK FLUID UNDER THE ANTI-LOCK BRAKES. THE DEALER SAID IT'S THE DESIGN OF THE BRAKES. TT
NHTSA ODI #978209
Official recalls
6Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93026 · Fuel Line Routing
Opened Oct 29, 1993 · Closed Feb 28, 1994
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91090 · Spare Tire Fires
Opened Jun 20, 1991 · Closed Oct 25, 1991
Status: closed (inferred from source dates) · Equipment
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available