NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
107 reportsMileage unknown · May 10, 2011
Fuel System, Gasoline
TL* THE CONTACT OWNS A 1990 FORD F250. THE CONTACT STATED THAT THE FUEL TANK STRAP WAS RUSTED AND LEAKING GAS. THE DEALER WAS MADE AWARE OF THE FAILURE HOWEVER, DID NOT OFFER ANY ASSISTANCE. THE MANUFACTURER WAS NOT CONTACTED TO REPORT THE FAILURE. THE CURRENT MILEAGE WAS 120,000 AND THE FAILURE MILEAGE WAS UNKNOWN. UPDATED…
Read full complaint
TL* THE CONTACT OWNS A 1990 FORD F250. THE CONTACT STATED THAT THE FUEL TANK STRAP WAS RUSTED AND LEAKING GAS. THE DEALER WAS MADE AWARE OF THE FAILURE HOWEVER, DID NOT OFFER ANY ASSISTANCE. THE MANUFACTURER WAS NOT CONTACTED TO REPORT THE FAILURE. THE CURRENT MILEAGE WAS 120,000 AND THE FAILURE MILEAGE WAS UNKNOWN. UPDATED 06/07/11*LJ THE CONSUMER STATED THE STRAP WAS NOT RUSTED, BUT IT DID WEAR A HOLE IN THE GAS TANK. UPDATED 06/23/11
NHTSA ODI #10399824
137,255 miles · May 5, 2010
Fuel System, Gasoline
I AM THE OWNER OF A 1990 F-250, BASICALLY BEGAN SMELLING A FUEL ODOR COMING FROM THE TRUCKS CAB WHILE DRIVING. LOOKED AT THE UNDERSIDE OF THE TRUCK AND FOUND A SMALL GAS LEAK AT THE FUEL LINES UNDER THE PINCH WELD. EXACT SAME ISSUE AS 94V040000, HAVE NOT FIXED PROBLEM BECAUSE FORD CANNOT FIND THIS ISSUE ON THERE SYSTEM. *TR
NHTSA ODI #10328970
112,209 miles · Apr 14, 2010
Fuel System, Gasoline
TL* THE CONTACT OWNS A 1990 FORD F250. THE CONTACT STATED THAT WHILE ATTEMPTING TO ACCELERATE FROM AT A TRAFFIC LIGHT, THE VEHICLE FELT AS IF IT WERE TRAVELING OVER A LARGE AMOUNT OF LIQUID. THE CONTACT OBSERVED EXCESSIVE FUEL LEAKING FROM THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER WHERE THE FAILURE COULD NOT BE DUPLICATED…
Read full complaint
TL* THE CONTACT OWNS A 1990 FORD F250. THE CONTACT STATED THAT WHILE ATTEMPTING TO ACCELERATE FROM AT A TRAFFIC LIGHT, THE VEHICLE FELT AS IF IT WERE TRAVELING OVER A LARGE AMOUNT OF LIQUID. THE CONTACT OBSERVED EXCESSIVE FUEL LEAKING FROM THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER WHERE THE FAILURE COULD NOT BE DUPLICATED. THE CONTACT BELIEVED NHTSA CAMPAIGN ID NUMBER:01I008000(FUEL SYSTEM, GASOLINE) TO BE DIRECTLY RELATED TO THE FAILURE. THE MANUFACTURER STATED THAT HIS VIN WAS NOT INCLUDED IN THE RECALL AND WOULD NOT PROVIDE ANY FURTHER ASSISTANCE. THE APPROXIMATE FAILURE MILEAGE WAS 112,209 AND THE APPROXIMATE CURRENT MILEAGE WAS 120,000.
NHTSA ODI #10325657
130,000 miles · Jan 23, 2008
Fuel System, Gasoline
TL*THE CONTACT OWNS A 1990 FORD F250. WHILE DRIVING 45 MPH, THE FUEL PUMP FAILED. THE CONTACT SMELLED GAS AND NOTICED A GAS LEAK. HE BOUGHT A NEW FUEL PUMP AND REPLACED THE BODIES; HOWEVER, THE FAILURE RECURRED. THE REAR FUEL TANK SHUT DOWN AND THE FRONT TANK DID NOT REGISTER ON THE FUEL GAUGE. THE CONTACT PURCHASED AND INS…
Read full complaint
TL*THE CONTACT OWNS A 1990 FORD F250. WHILE DRIVING 45 MPH, THE FUEL PUMP FAILED. THE CONTACT SMELLED GAS AND NOTICED A GAS LEAK. HE BOUGHT A NEW FUEL PUMP AND REPLACED THE BODIES; HOWEVER, THE FAILURE RECURRED. THE REAR FUEL TANK SHUT DOWN AND THE FRONT TANK DID NOT REGISTER ON THE FUEL GAUGE. THE CONTACT PURCHASED AND INSTALLED NEW FUEL LINES, BUT THE FAILURE RECURRED. HE BOUGHT NEW FUEL LINES AGAIN, BUT THE FAILURE CONTINUED. THE DEALER INFORMED THE CONTACT THAT THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN ID NUMBER 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). HE WENT TO A FEW DEALERS AND WAS INFORMED THAT HE DID NOT FALL WITHIN THE TIME FRAME FOR THE RECALL. THE PURCHASE DATE WAS UNKNOWN. THE CURRENT MILEAGE WAS 160,000 AND FAILURE MILEAGE WAS 130,000.
NHTSA ODI #10215764
122,000 miles · Aug 22, 2006
Fuel System, Gasoline
DT*: THE CONTACT STATED WHEN THE VEHICLE WAS USING THE FRONT FUEL TANK, THE FUEL WAS EXHAUSTED QUICKLY. FUEL ALSO LEAKED OUT OF THE REAR TANK. THE VEHICLE WAS TAKEN TO A PRIVATE REPAIR SHOP WHO DETERMINED THAT THE CHECK VALVE HAD MALFUNCTIONED. THERE WERE NO IMMEDIATE REPAIRS MADE. THERE WAS A NHTSA RECALL # 93V125000, WHICH…
Read full complaint
DT*: THE CONTACT STATED WHEN THE VEHICLE WAS USING THE FRONT FUEL TANK, THE FUEL WAS EXHAUSTED QUICKLY. FUEL ALSO LEAKED OUT OF THE REAR TANK. THE VEHICLE WAS TAKEN TO A PRIVATE REPAIR SHOP WHO DETERMINED THAT THE CHECK VALVE HAD MALFUNCTIONED. THERE WERE NO IMMEDIATE REPAIRS MADE. THERE WAS A NHTSA RECALL # 93V125000, WHICH PERTAINED TO THE FUEL TANK ASSEMBLY. THE VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO THE VIN. UPDATED 09/19/06. *JB
NHTSA ODI #10166215
69,000 miles · Aug 15, 2005
Service Brakes, Hydraulic
DT NHTSA RECALL 92V026000 WAS ISSUED. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. MY BRAKES FAILED. THE DEALER HAS NOT LOOKED AT THE VEHICLE BECAUSE THEY WOULD CHARGE THE CONSUMER FOR THE REPAIRS. CONTACTED FORD, THEY GAVE THE RUN AROUND. THERE WAS NO WARNING BEFORE THE BRAKES WENT OUT. THE BRAKE FL…
Read full complaint
DT NHTSA RECALL 92V026000 WAS ISSUED. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. MY BRAKES FAILED. THE DEALER HAS NOT LOOKED AT THE VEHICLE BECAUSE THEY WOULD CHARGE THE CONSUMER FOR THE REPAIRS. CONTACTED FORD, THEY GAVE THE RUN AROUND. THERE WAS NO WARNING BEFORE THE BRAKES WENT OUT. THE BRAKE FLUID WAS OVER HEATING. THE BRAKE PEDAL WENT DOWN TO THE FLOOR. HAD TO USE EMERGENCY BRAKE, AND THE BRAKES ON THE BOAT THAT I WAS TOWING. THIS HAPPENED ON FRIDAY AUGUST 12, 2005. *AK
NHTSA ODI #10132860
61,067 miles · Mar 7, 2005
Fuel System, Gasoline
CONSUMER CONCERNED ABOUT RECALL ON 1990 FORD F250 FUEL TANK. *BF THE VEHICLE'S FRONT TANK PUSHED FUEL TO THE REAR TANK WHICH CAUSED IT TO OVERFLOW. THE VEHICLE WAS TAKEN TO AN INDEPENDENT REPAIR FACILITY WHO FOUND RECALL 93S68 WHICH REFERENCED THAT FAILURE. THE CONSUMER NEVER RECEIVED A RECALL NOTICE FROM THE MANUFACTURER. …
Read full complaint
CONSUMER CONCERNED ABOUT RECALL ON 1990 FORD F250 FUEL TANK. *BF THE VEHICLE'S FRONT TANK PUSHED FUEL TO THE REAR TANK WHICH CAUSED IT TO OVERFLOW. THE VEHICLE WAS TAKEN TO AN INDEPENDENT REPAIR FACILITY WHO FOUND RECALL 93S68 WHICH REFERENCED THAT FAILURE. THE CONSUMER NEVER RECEIVED A RECALL NOTICE FROM THE MANUFACTURER. THE CONSUMER CONTACTED THE MANUFACTURER WHO INFORMED HIM THAT HE WAS OVER THE MILEAGE AND TIME ALLOTTED FOR THE RECALL. THE INDEPENDENT DEALER REPLACED THE FAULTY CHECK VALVE, REGULATOR AND FUEL PUMP BUT THIS DID NOT CORRECT THE OVERFLOW CONDITION. *NM
NHTSA ODI #10114888
Mileage unknown · Feb 17, 2005
Fuel System, Gasoline
I HAVE A 1990 FORD F250 WITH DUEL GAS TANKS. THE FIRST PROBLEM WAS THE TRUCK WOULD DIE FOR WHAT SEEMED LIKE NO OBVIOUS REASON. I HAD A DIAGNOSTIC DONE TO NO AVAIL. THE TRUCK WOULD RUN FINE COLD, BUT ONCE IT GOT HOT IT WOULD DIE. FINALLY I TOOK IT TO A LOCAL MECHANIC AND HE FOUND IT WAS THE TANK SELECTOR SWITCH WHICH LETS ME CHO…
Read full complaint
I HAVE A 1990 FORD F250 WITH DUEL GAS TANKS. THE FIRST PROBLEM WAS THE TRUCK WOULD DIE FOR WHAT SEEMED LIKE NO OBVIOUS REASON. I HAD A DIAGNOSTIC DONE TO NO AVAIL. THE TRUCK WOULD RUN FINE COLD, BUT ONCE IT GOT HOT IT WOULD DIE. FINALLY I TOOK IT TO A LOCAL MECHANIC AND HE FOUND IT WAS THE TANK SELECTOR SWITCH WHICH LETS ME CHOOSE THE FRONT OR REAR GAS TANK. THIS FIRST SWITCH COST ME $300.00 TO FIX. ITS BEEN ABOUT 8 MONTHS SINCE THE SWITCH WAS REPLACED. IT JUST WENT OUT AGAIN. THIS TIME I REPLACED IT MYSELF WITH A SWITCH FROM A FORD DEALER. WHEN I UNHOOKED THE SWITCH FROM THE HARNESS IT WAS MELTED ON THE INSIDE OF THE SWITCH AND THE HARNESS WAS ALMOST UNUSABLE. I WENT TO A LOCAL FORD DEALER AND THE SALES CLERK SAID THAT THIS IS A COMMON PROBLEM BECAUSE HE SELLS THESE SWITCHES A LOT AND THIS WAS NOT THE FIRST TIME HE HEARD OF THE SWITCH MELTING. THIS IS A FIRE WAITING TO HAPPEN. FORD SHOULD RECALL THIS PART AND FIX THE ROOT OF THE PROBLEM. *JB
NHTSA ODI #10110729
Mileage unknown · Jan 13, 2005
Fuel System, Gasoline
THE TRUCK FRONT FUEL TANK FILLED THE REAR TANK AND CAUSED IT TO OVER FLOW. *BF THE CONSUMER INDICATED THAT HE NEVER RECEIVED THE RECALL NOTICE FOR THE FUEL TANK CHECK VALVE PROBLEM. THE DEALER REPLACED THE RECALLED COMPONENT BUT THE FAILURE RECURRED. THE DEALER ALSO REPLACED THE FUEL PUMP, RETURN LINE CHECK VALVE BUT THE FUE…
Read full complaint
THE TRUCK FRONT FUEL TANK FILLED THE REAR TANK AND CAUSED IT TO OVER FLOW. *BF THE CONSUMER INDICATED THAT HE NEVER RECEIVED THE RECALL NOTICE FOR THE FUEL TANK CHECK VALVE PROBLEM. THE DEALER REPLACED THE RECALLED COMPONENT BUT THE FAILURE RECURRED. THE DEALER ALSO REPLACED THE FUEL PUMP, RETURN LINE CHECK VALVE BUT THE FUEL LEAKAGE CONTINUED. *NM
NHTSA ODI #10110883
198,200 miles · Aug 31, 2004
Fuel System, Gasoline
REFERENCE NHTSA CAMPAIGN # 93V125000 RECALL # 93S68. (1) THE VEHICLE HAD BEEN DRIVEN ABOUT ONE HOUR - WHILE PARKING IN FRONT OF THE HOUSE ON THE STREET, I NOTICED A STRONG SMELL OF GASOLINE. I WAS RUNNING ON THE BACK TANK AND QUICKLY SWITCHED TO THE FRONT TANK. AFTER SHUTTING OFF THE IGNITION AND EXITING VEHICLE I SAW GASOLIN…
Read full complaint
REFERENCE NHTSA CAMPAIGN # 93V125000 RECALL # 93S68. (1) THE VEHICLE HAD BEEN DRIVEN ABOUT ONE HOUR - WHILE PARKING IN FRONT OF THE HOUSE ON THE STREET, I NOTICED A STRONG SMELL OF GASOLINE. I WAS RUNNING ON THE BACK TANK AND QUICKLY SWITCHED TO THE FRONT TANK. AFTER SHUTTING OFF THE IGNITION AND EXITING VEHICLE I SAW GASOLINE SPILLING OUT OF THE FRONT TANK FROM UNDER THE CAP (STILL ON). THIS CONTINUED FOR SOME 5-10 SECONDS AND THEN STOPPED. WHEN I LOOSENED THE CAP, THE FLOW OF GASOLINE RESTARTED - AND STOPPED AGAIN WHEN CAP WAS TIGHTENED BACK DOWN. (2) THANKFULLY, THE FAILURE DID NOT RESULT IN FIRE OR LOSS OF PROPERTY - ONLY FUEL LOSS AND PERSONAL ANXIETY AND EXPENSE. (3) WEB RESEARCH REVEALED THE ABOVE RECALL AND WHEN SPEAKING TO A FMC REPRESENTATIVE AT THE HOTLINE I WAS ADVISED THAT THIS VEHICLE HAD RECEIVED THE RECALL REPAIR. I WAS ALSO ADVISED THAT THE WARRANTY PERIOD HAD EXPIRED DEC.31, 2001 AND I WOULD BE RESPONSIBLE FOR ANY REPAIRS. WHEN PRESENTED TO THE DEALERSHIP FOR REPAIRS, I WAS ADVISE THAT THE FUEL PUMP VALVE REPAIRS WOULD BE MY RESPONSIBILTY AND NOT COVERED BY FMC. WHY DOES THE RECALL REPAIR FAIL? AND WHY DOES THE CONSUMER HAVE TO FOOT THE BILL?*AK
NHTSA ODI #10088911
Official recalls
6Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93026 · Fuel Line Routing
Opened Oct 29, 1993 · Closed Feb 28, 1994
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91090 · Spare Tire Fires
Opened Jun 20, 1991 · Closed Oct 25, 1991
Status: closed (inferred from source dates) · Equipment
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train