← New search

1993 Ford F-350

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1993 Ford F-350 do not stand out strongly from the model-year median of 93.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all F-350 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 17 of 101 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Service Brakes, Hydraulic. Review the 25 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 21 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

5 crash reports5 fire reports1 injury reports

What owners actually said

101 reports
45,000 miles · Feb 25, 2005
Engine And Engine Cooling

WHILE DRIVING THE SERPENTINE BELT SNAPPED OFF. THIS CAUSED THE VEHICLE TO LOSE POWER AND EXTENDED STOPPING DISTANCE. THE DEALERSHIP WAS NOTIFIED, BUT DID NOT RESOLVE PROBLEM. THE CAUSE WAS NOT DETERMINED. PLEASE PROVIDE MORE INFORMATION. *NM

NHTSA ODI #10113074

172,000 miles · Feb 15, 2005
Vehicle Speed ControlFire

WHILE VEHICLE WAS PARKED A FIRE STARTED UNDER THE HOOD. DEALERSHIP WAS NOTIFIED, BUT DID NOT RESOLVE THE PROBLEM. *AK

NHTSA ODI #10111522

90,000 miles · Feb 9, 2005
Power Train

THE CLUTCH GOT STUCK IN DRIVE. CONSUMER HAD TO APPLY THE BRAKES IN ORDER TO STOP THE VEHICLE. CONSUMER WAS NOT ABLE TO REMOVE THE GEAR, AND THE VEHICLE IS IN THE SHOP FOR T REPAIRS. *AK

NHTSA ODI #10111245

52,500 miles · Dec 27, 2004
Engine And Engine Cooling

EXHAUST FUMES WERE LEAKING INTO THE CAB OF THE VEHICLE. CONSUMER CONTACTED THE DEALER, WHO DIDN'T THINK THAT THIS PROBLEM WAS IMPORTANT, AND WILL NOT SERVICE VEHICLE IN A TIMELY MANOR. ALSO, CONSUMER ASKED FOR MANUFACTURER'S TELEPHONE NUMBER, BUT THE DEALER REFUSED TO COOPERATE. *AK

NHTSA ODI #10105360

179,000 miles · Sep 20, 2004
Engine And Engine Cooling

SERPENTINE BELT DETACHES FROM TENSION PULLEY AND/OR IDLER PULLEY. DETACHED BELT CAUSES DAMAGE TO TRANSMISSION COOLER LINES, RADIATOR LINES, AND BREAKS IDLER PULLEY FROM BRACKET. POWER STEERING AND BRAKING ARE LOST MAKING VEHICLE VERY DIFFICULT TO CONTROL. FLYING IDLER PULLEY MAY CAUSE ADDITIONAL DAMAGE AND/OR FALLS TO ROADWAY A…

Read full complaint

SERPENTINE BELT DETACHES FROM TENSION PULLEY AND/OR IDLER PULLEY. DETACHED BELT CAUSES DAMAGE TO TRANSMISSION COOLER LINES, RADIATOR LINES, AND BREAKS IDLER PULLEY FROM BRACKET. POWER STEERING AND BRAKING ARE LOST MAKING VEHICLE VERY DIFFICULT TO CONTROL. FLYING IDLER PULLEY MAY CAUSE ADDITIONAL DAMAGE AND/OR FALLS TO ROADWAY AS HAZARD. DAMAGE TO TRANSMISSION LINES MAY CAUSE FIRE. CAUSED BY UNEVEN WEAR TO THE PLASTIC BELT TENSIONER PULLEY. PLASTIC PULLEY DEFORMS IN SUCH A MANNER THAT THE SERPENTINE BELT TRAVELS FORWARD (TOWARD FAN) AND OFF OF PULLEY. A SIMILAR DEFECT (NHTSA CAMPAIGN NUMBER 96I003000) WAS REMEDIED WITH A VOLUNTARY RECALL BY FORD IN 1996. THIS PARTICULAR VEHICLE WAS REPAIRED TO THAT STANDARD. THE STANDARD APPEARS TO HAVE BEEN INADEQUATE. *AK

NHTSA ODI #10091352

111,000 miles · Apr 13, 2004
Engine And Engine Cooling

WHEN THE VEHICLE IDLED CONSUMER SMELLED AND HEARD EXHAUST LEAKING. DEALER EXAMINED THE VEHICLE, AND FOUND THAT THE EXHAUST GAS RECIRCULATION TUBE (EGR) HAD A HOLE IN IT. *AK

NHTSA ODI #10067097

200,000 miles · Apr 8, 2003
Service Brakes, Hydraulic

THE REAR BRAKES LOCKED UP, WHEN THEY WERE PRESSED. *JB

NHTSA ODI #10015413

156,939 miles · Mar 10, 2003
Power Train

CLUTCH MASTER CYLINDER, PUSH ROD PLASTIC EXTENSION FRACTURED AND BROKE WHILE VEHICLE WAS IN MOTION ON THE HIGHWAY. THE VEHICLE WAS UNABLE TO BE SHIFTED OUT OF GEAR AND WAS UNABLE TO STOP FORWARD MOTION UNTIL THE ENGINE WAS STOPPED. WITH FURTHER INSPECTION OF THE COMPONENT I WAS ABLE TO DETERMINE THAT WEAR AND LUBRICATIONS WILL…

Read full complaint

CLUTCH MASTER CYLINDER, PUSH ROD PLASTIC EXTENSION FRACTURED AND BROKE WHILE VEHICLE WAS IN MOTION ON THE HIGHWAY. THE VEHICLE WAS UNABLE TO BE SHIFTED OUT OF GEAR AND WAS UNABLE TO STOP FORWARD MOTION UNTIL THE ENGINE WAS STOPPED. WITH FURTHER INSPECTION OF THE COMPONENT I WAS ABLE TO DETERMINE THAT WEAR AND LUBRICATIONS WILL CAUSE THIS FAILURE. AN ENTIRE ALL METAL UNIT SHOULD REPLACE THIS COMPONENT. VEHICLE WAS AT 150,000 MILES WHEN FAILURE OCCURRED.*JB

NHTSA ODI #10010207

Mileage unknown · Dec 11, 2002
Engine And Engine Cooling

WHEN VEHICLE IS BEING DRIVEN THE BELT TENSIONER KEEPS SHREDDING SERPENTINE BELT, CAUSING VEHICLES ENGINE TO DIED. IN ONE CASE THE BELT TENSION SHIERD OFF, SENDING A METAL BOLT FROM ENGINE THAT PUNCTURED RADIATOR FAN. PLEASE PROVIDE ANY FURTHER INFORMATION. MR

NHTSA ODI #8024185

Mileage unknown · Sep 3, 2002
Power Train

WHILE DRIVING CONSUMER TRIED TO PUSH CLUTCH IN THE BUSHING BROKE, AND THE LINKAGE FELL APART, MAKING CLUTCH INOPERATIVE. *AKCONSUMER HAD NOT FOLLOWED UP ON THE FINAL RESPONSE TO THE COMPLAINT FILED VIA TELEPHONE BECAUSE THE VEHICLE BROKE DOWN 800 MILES FROM HIS HOME. CONSUMER FEELS A RECALL SHOULD BE ISSUED TO REPAIR THIS PROB…

Read full complaint

WHILE DRIVING CONSUMER TRIED TO PUSH CLUTCH IN THE BUSHING BROKE, AND THE LINKAGE FELL APART, MAKING CLUTCH INOPERATIVE. *AKCONSUMER HAD NOT FOLLOWED UP ON THE FINAL RESPONSE TO THE COMPLAINT FILED VIA TELEPHONE BECAUSE THE VEHICLE BROKE DOWN 800 MILES FROM HIS HOME. CONSUMER FEELS A RECALL SHOULD BE ISSUED TO REPAIR THIS PROBLEM. THE FAILURE TO COMSUMERS VEHICLE WAS DUE TO A PUSH ROD MAST. *JG

NHTSA ODI #8017814

Official recalls

6

08V051000 · Vehicle Speed Control:cruise Control

Feb 4, 2008

FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Consequence & remedy

Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

07V336000 · Vehicle Speed Control

Aug 3, 2007

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

00V424000 · Fuel System, Gasoline:storage:tank Assembly

Dec 29, 2000

VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.

Consequence & remedy

Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.

Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).

94V169001 · Parking Brake:conventional

Sep 7, 1994

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence & remedy

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

94V018000 · Structure:body:bumpers

Jan 2, 1994

THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.

Consequence & remedy

Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.

Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

3

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

EA95012 · Failure Of Serpentine Belt

Opened Mar 31, 1995 · Closed May 28, 1996

Status: closed (inferred from source dates) · Power Train

AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.

Additional source detail variants (2)

Power Train

AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.

Power Train

AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.

PE94004 · Hydraulic Brake Line Cracks/leaks

Opened Jan 25, 1994 · Closed Apr 29, 1994

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available