TL* THE CONTACT OWNS A 1993 FORD F-350 EQUIPPED WITH BCT HI-RUN TIRES, SIZE L235/85R16 (NA). WHILE DRIVING APPROXIMATELY 65 MPH, THE FRONT DRIVER SIDE TIRE BLEW OUT. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHERE IT WAS DIAGNOSED THAT THE TIRE TREADS WERE SEPARATING FROM THE TIRES AND THE TIRES NEEDED TO BE REPLACED. WHI…
Read full complaint
TL* THE CONTACT OWNS A 1993 FORD F-350 EQUIPPED WITH BCT HI-RUN TIRES, SIZE L235/85R16 (NA). WHILE DRIVING APPROXIMATELY 65 MPH, THE FRONT DRIVER SIDE TIRE BLEW OUT. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHERE IT WAS DIAGNOSED THAT THE TIRE TREADS WERE SEPARATING FROM THE TIRES AND THE TIRES NEEDED TO BE REPLACED. WHILE AT THE INDEPENDENT MECHANIC, THE OTHER THREE TIRES BLEW OUT. THE TIRES WERE NOT REPAIRED. THE TIRES WERE NOT ORIGINAL EQUIPMENT. THE MANUFACTURER WAS NOTIFIED OF THE FAILURES. THE APPROXIMATE VEHICLE FAILURE MILEAGE WAS 190,000 AND THE TIRE FAILURE MILEAGE WAS 4,000. THE VIN AND DOT NUMBER WERE NOT PROVIDED.
NHTSA ODI #10852299
86,000 miles · Aug 28, 2006
Tires
DT*: THE CONTACT STATED WHILE DRIVING 60 MPH ON THE INTERSTATE IN NORMAL ROAD CONDITIONS, THE LEFT INNER DUALLY TIRE TREAD SEPARATED WITHOUT WARNING. THE CONTACT MANAGED TO PULL OVER WITHOUT INCIDENT. UPON INITIAL INSPECTION, THE CARCASS OF THE TIRE REMAINED INFLATED, YET THE TREAD WAS COMPLETELY SEPARATED. THERE WAS DAMAGE …
Read full complaint
DT*: THE CONTACT STATED WHILE DRIVING 60 MPH ON THE INTERSTATE IN NORMAL ROAD CONDITIONS, THE LEFT INNER DUALLY TIRE TREAD SEPARATED WITHOUT WARNING. THE CONTACT MANAGED TO PULL OVER WITHOUT INCIDENT. UPON INITIAL INSPECTION, THE CARCASS OF THE TIRE REMAINED INFLATED, YET THE TREAD WAS COMPLETELY SEPARATED. THERE WAS DAMAGE TO THE FUEL LINES FROM THE INITIAL TIRE TREAD SEPARATION. THERE WERE NO OBVIOUS ROAD HAZARD OR DEBRIS. THE MANUFACTURER WAS NOT ALERTED. THE TIRE WAS A BRIDGESTONE LT 215/85/R16, LOAD RANGE E. UPDATED 03/30/07. *JB
NHTSA ODI #10166763
116,374 miles · Aug 22, 2005
Tires
TIRE TREAD SEPARATION ON LOW MILEAGE TIRE. TIRE MODEL WILD COUNTRY APT LT235/85R-16. MILEAGE VERIFIED AT 21,152MI. VEHICAL DAMAGE DUE TO TIRE TREAD IMPACTING AUTO AND BRAKE LINES. NO INJURIES. TIRE WAS A REAR TIRE, SO WE HAD TO REPLACE BOTH TIRES.
NHTSA ODI #10133787
Mileage unknown · Jan 22, 2001
Tires
FIRESTONE STEELTEX RADIAL AT TIRE (P235/85R16) EXPERIENCED SIDEWALL SEPARATION. *SLC
NHTSA ODI #559138
Mileage unknown · Nov 13, 2000
Tires
DRIVER'S SIDE TIRE TREAD SEPARATED. *AK BOTH STEEL TEX R4S TIRES HAD TREAD SEPARATED WHILE TRAVELING. *YH
NHTSA ODI #874831
Mileage unknown · Oct 10, 2000
Tires
ON 9/27/2000, I HAD THE ANNUAL VEHICLE INSPECTION IN ACCORDANCE WITH VIRGINIA STATE LAW. AT THAT TIME, THE INSPECTOR BROUGHT TO MY ATTENTION THAT 4 OF THE SIX TIRES HAD CRACKING IN THE AREA WHERE TREAD SEPARATION WOULD NORMALLY OCCUR. I USE THIS VEHICLE NORMALLY TO PULL MY FIFTH WHEEL RECREATION VEHICLE. OBVIOUSLY, THE TIRE C…
Read full complaint
ON 9/27/2000, I HAD THE ANNUAL VEHICLE INSPECTION IN ACCORDANCE WITH VIRGINIA STATE LAW. AT THAT TIME, THE INSPECTOR BROUGHT TO MY ATTENTION THAT 4 OF THE SIX TIRES HAD CRACKING IN THE AREA WHERE TREAD SEPARATION WOULD NORMALLY OCCUR. I USE THIS VEHICLE NORMALLY TO PULL MY FIFTH WHEEL RECREATION VEHICLE. OBVIOUSLY, THE TIRE CRACKING GAVE ME MUCH CONCERN. TODAY, 10/10/200, I HAD ALL FIRESTONE TIRES REPLACED. FURTHER INSPECTION INDICATED THAT ALL TIRES SHOW SOME INDICATION OF CRACKING. (DOT NUMBER: VNOP1WV053 TIRESIZE: LT21585R16)
NHTSA ODI #733897
Mileage unknown · Oct 2, 2000
Tires
RIGHT FRONT TIRE BLEWOUT WHILE DRIVING, THE PLIES SEPARATED AND THE TIRE IMMEDIATELY DISINTEGRATED CAUSING LOSS OF CONTROL, NOY ONLY DUE TO THE TIRE BUT BECAUSE THE AUTOMATIC FUEL PUMP SHUT OFF SWITCH WAS ACTIVATED BECAUSE OF THE VIBRATION FROM THE BLOWN TIRE (MICHELIN XCH-4 LT 225/75R16). NLM
NHTSA ODI #555712
Mileage unknown · Sep 21, 2000
Tires
PE00020, ORIGINAL EQUIPMENT ON 1993 FORD F350, TIRE SIZE LT23585R16. FRONT PASSENGER'S TIRE AND THE REAR DRIVER'S TIRE TREAD CAME APART WHICH CAUSED TIRE TO EXPLODE, ALMOST RESULTING IN A CRASH. *AK TWO TIRES SEPERATED AND EXPLODED. SEPERATE INCIDENTS APPROXIMATELY 6-12 MONTHS APART. *YH
NHTSA ODI #871180
Mileage unknown · Aug 14, 2000
Tires
TREAD BECAME COMPLETELY REMOVED FROM THE TIRE WITHOUT LOOSING ANY AIR. THE TIRE REMAINED INFLATED BUT WITHOUT THE TREAD.*AK( DOT NUMBER: TIRE SIZE: LT24575R16 )
NHTSA ODI #727825
Mileage unknown · Aug 10, 2000
Tires
WHILE DRIVING ABOUT 60 MPH LEFT REAR TIRE TREAD SEPARATED, BUT, CONSUMER KEPT CONTROL OF VEHICLE. FIRESTONE AT TIRES. *AK ON SECOND OCCASION RIGHT REAR TIRE TREAD SEPARATED WHILE DRIVING AT 55 MPH. *YH
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Consequence & remedy
Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.
Consequence & remedy
Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.
Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.
Consequence & remedy
Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.
Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
3
EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
EA95012 · Failure Of Serpentine Belt
Opened Mar 31, 1995 · Closed May 28, 1996
Status: closed (inferred from source dates) · Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
Additional source detail variants (2)
Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
PE94004 · Hydraulic Brake Line Cracks/leaks
Opened Jan 25, 1994 · Closed Apr 29, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available