MY FORD F350 CREWCAB CAUGHT ON FIRE FOR NO APPARENT REASON. I AM JUST NOW FINDING OUT THAT THERE IS A RECALL ON MY VEHICLE BECAUSE OF SPONTANEOUS FIRES ON MY YEAR AND MODEL. I SPENT ALMOST $3000.00 ON REPAIRS AND HAVE BEEN HAVING ONGOING PROBLEMS WITH THE ENGINE QUITTING WHILE DRIVING. I WOULD LIKE TO KNOW IF THERE IS ANY REMEDY…
Read full complaint
MY FORD F350 CREWCAB CAUGHT ON FIRE FOR NO APPARENT REASON. I AM JUST NOW FINDING OUT THAT THERE IS A RECALL ON MY VEHICLE BECAUSE OF SPONTANEOUS FIRES ON MY YEAR AND MODEL. I SPENT ALMOST $3000.00 ON REPAIRS AND HAVE BEEN HAVING ONGOING PROBLEMS WITH THE ENGINE QUITTING WHILE DRIVING. I WOULD LIKE TO KNOW IF THERE IS ANY REMEDY THAT I CAN OBTAIN FROM FORD. I HAVE NOT BEEN ABLE TO USE THIS TRUCK FOR OVER 2 YEARS BECAUSE OF THE ENGINE QUITTING AND THEN A NO START SITUATION. VEHICLE WILL START AFTER IT COOLS DOWN BUT WILL STOP WITHIN A HALF HOUR.THIS IS FRUSTRATING BECAUSE THIS IS MY ONLY VEHICLE AND I HAVE LOST USE OF THE TRUCK AND HAD TO STOP WORKING BECAUSE I AM A CONSTRUCTION CONTRACTOR AND NEEDED IT TO WORK. I HAVE HAD THE TRUCK TO THE DEALER NUMEROUS TIMES. AFTER RESEARCHING PROBLEMS ONLINE I HAD ONLY FOUND OUT THEN ABOUT POSSIBLE UNDERHOOD FIRES ON MY VEHICLE. I ALSO FOUND OUT ABOUT OTHER TSB AND RECALL INFORMATION OF WHICH I HAD NOT BEEN NOTIFIED. *TR
NHTSA ODI #10262715
111,330 miles · Feb 25, 2009
Fuel System, Gasoline
1993 FORD F-350 WITH A 5.8 ENGINE, I RECEIVED THIS INFO. FROM ALLDATA. I READ ON FORD'S WEB SITE THAT A SAFETY RECALL GENERALLY NEVER EXPIRES... RECALL #'S 00S57 FUEL PRESSURE REGULATOR REPLACEMENT, # 00V424000 FUEL PRESSURE REGULATOR MALFUNCTION, # 01L008000 FUEL PUMP CHECK VALVE DEFECT., ALL THREE OF THESE HAVE THE SAME SYMPTO…
Read full complaint
1993 FORD F-350 WITH A 5.8 ENGINE, I RECEIVED THIS INFO. FROM ALLDATA. I READ ON FORD'S WEB SITE THAT A SAFETY RECALL GENERALLY NEVER EXPIRES... RECALL #'S 00S57 FUEL PRESSURE REGULATOR REPLACEMENT, # 00V424000 FUEL PRESSURE REGULATOR MALFUNCTION, # 01L008000 FUEL PUMP CHECK VALVE DEFECT., ALL THREE OF THESE HAVE THE SAME SYMPTOMS, CAUSES FUEL FROM THE REAR TANK TO TRANSFER TO THE FRONT TANK AND CAUSE FUEL TO RUN OUT OF THE FUEL FILLER NECK OF THE FRONT TANK AND DOWN THE SIDE OF THE TRUCK ONTO THE GROUND. I HAVE OWNED THE TRUCK FOR 6 YEARS AND HAVE NEVER RECEIVED ANY TYPE OF NOTICE FOR THIS, ONE NOTICE STATES THAT VEHICLE OWNERS WOULD BE NOTIFIED STARTING MAY 2001, FORD SENT ME AN EMAIL TODAY STATING THAT THEY WOULD NOT REPAIR THIS, I EVEN SENT THEM THE RECALL #'S, I HOPE THAT YOU CAN OFFER ME SOME HELP ON THIS, AS I REALLY DO NOT WANT MY TRUCK TO CATCH FIRE WITH OR WITHOUT MY FAMILY IN IT. THANK YOU *TR UPDATED 03/06/09. *JB
NHTSA ODI #10259955
93,600 miles · Jul 24, 2006
Fuel System, Gasoline
I WAS USING MY REAR GAS TANK IN MY DUAL TANK SYSTEM. THE FUEL ,IN ADDITION TO OPERATING THE VEHICLE, PUMPED INTO THE HALF FULL FRONT TANK. WHEN I WENT TO FILL THE FRONT TANK AT THE FILLING STATION, THE FUEL FORCIBLY SPILLED OUT OF THE FRONT TANK, SPRAYING ON ME. *NM
NHTSA ODI #10163341
Mileage unknown · Aug 8, 2001
Fuel System, Gasoline
CONSUMER RECEIVED RECALL NOTICE FOR CAMPAIGN 00V424000 IN MAIL. WHEN CONTACTING DEALERSHIP, WAS INFORMED THAT VEHICLE WOULD NOT BE REPAIRED UNLESS HE WAS EXPERIENCING THIS PROBLEM. PLEASE PROVIDE ANY ADDITIONAL INFORMATION/ATTACHMENTS.*AK
NHTSA ODI #893782
Mileage unknown · Jun 8, 2001
Fuel System, Gasoline
RECALL 93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, WHEN THIS OCCURRED, SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION;.MANUFACTURER WAS NOTIFIED, AND INFORMED THAT RECALL REPAIRS WAS COMPLETED ON THA…
Read full complaint
RECALL 93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, WHEN THIS OCCURRED, SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION;.MANUFACTURER WAS NOTIFIED, AND INFORMED THAT RECALL REPAIRS WAS COMPLETED ON THAT VEHICLE, AND NO OTHER REPAIRS WOULD BE MADE. FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER . *AK
NHTSA ODI #890033
Mileage unknown · May 1, 2001
Fuel System, GasolineUnknown Or Other
ENGIE CHECK LIGHT COMES ON FOR REAR TANK. GAS LEAKS FROM GAS LINE WHERE NOZZLE IS INSERTED. WHEN BOTH TANKS ARE FULL SWITCH VALVE CAUSES VEHICLE TO ALMOST STALL. ALSO, WHEN THEY ARE FULL THEY MAKE A LOUD HUMMING NOISE ONCE GAS BURNS OUT NOISE GRADUALLY GOES AWAY.*AK
NHTSA ODI #887231
Mileage unknown · Apr 6, 2001
Fuel System, Gasoline
WHEN SWITCHING FROM ONE TANK TO SECOND FUEL TANK FUEL IS NOT BEING PUMPED TO ENGINE OF VEHICLE. MANUFACTURER INFORMED CONSUMER THATR THIS VEHICLE WAS NOT INCLUDED IN ANY RECALL. PLEASE PROVIDE ANY ADDITIONAL INFORMATION/ATTACHMENTS.*AK
NHTSA ODI #885279
Mileage unknown · Mar 14, 2001
Fuel System, Gasoline
THIS TRUCK HAS TWO TANKS. WHEN DRIVING RESERVE TANK PUSHES ALL FUEL INTO FRONT TANK, CAUSING AN OVERFLOW. DEALER HAS BEEN CONTACTED. THERE IS A RECALL, BUT THIS VEHICLE WAS NOT COVERED.*AK CONSUMER STATES THIS PROBLEM HAS BEEN CONTINUOUS FOR ABOUT 2 YEARS. *SLC
NHTSA ODI #882971
Mileage unknown · Feb 26, 2001
Fuel System, Gasoline
WHILE TRAVELING OR MAKING STOPS NOTICED GAS SMELL INSIDE VEHICLE. DEALER HAS BEEN CONTACTED. *AK DEALER INDICATED THAT THE VEHICLE WAS NOT ON RECALL. *YH
NHTSA ODI #881421
Mileage unknown · May 22, 2000
Fuel System, Gasoline
WHILE DRIVING FUEL COULD PASS FROM ONE TANK TO THE OTHER, FORCING A FUEL SPILLAGE. CONSUMER IS AFRAID OF A WORSE SITUATION. *AK
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Consequence & remedy
Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.
Consequence & remedy
Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.
Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.
Consequence & remedy
Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.
Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
3
EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
EA95012 · Failure Of Serpentine Belt
Opened Mar 31, 1995 · Closed May 28, 1996
Status: closed (inferred from source dates) · Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
Additional source detail variants (2)
Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
Power Train
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
PE94004 · Hydraulic Brake Line Cracks/leaks
Opened Jan 25, 1994 · Closed Apr 29, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available