NHTSA owner reports · September 18, 2026 snapshot.
Fuel System, Gasoline complaints
26 reportsClear category filter150,000 miles · Aug 9, 2011
Fuel System, Gasoline
TL* THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT AFTER REFUELING THE VEHICLE, GASOLINE WOULD OVERFLOW FROM THE REAR FUEL TANK INTO THE FRONT FUEL TANK, CAUSING SPILLAGE. THE CONTACT BELIEVED THAT THE FUEL PUMP WAS DEFECTIVE. THE VEHICLE WAS TAKEN TO THE DEALER WHO ADVISED THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA…
Read full complaint
TL* THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT AFTER REFUELING THE VEHICLE, GASOLINE WOULD OVERFLOW FROM THE REAR FUEL TANK INTO THE FRONT FUEL TANK, CAUSING SPILLAGE. THE CONTACT BELIEVED THAT THE FUEL PUMP WAS DEFECTIVE. THE VEHICLE WAS TAKEN TO THE DEALER WHO ADVISED THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY). THE DEALER ADVISED THAT THE ENTIRE FUEL TANK WOULD NEED REPLACING. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE VEHICLE WAS NOT REPAIRED AND THE VIN WAS UNAVAILABLE. THE FAILURE MILEAGE WAS 150,000.
NHTSA ODI #10418150
38,525 miles · Nov 16, 2010
Fuel System, Gasoline
TL*THE CONTACT OWNS A 1991 FORD F250. THE CONTACT STATED WHILE DRIVING APPROXIMATELY 45 MPH, HE NOTICED GASOLINE SPILLING OUT OF THE TANK. PRIOR TO THE SPILL, HE SMELLED A GASOLINE ODOR FOR ABOUT 6 MONTHS. THE VEHICLE WAS INSPECTED BY PEPBOYS WHO INFORMED THE CONTACT THAT THE FUEL TANK SELECTOR NEEDED TO BE REPLACED. THE VIN WAS…
Read full complaint
TL*THE CONTACT OWNS A 1991 FORD F250. THE CONTACT STATED WHILE DRIVING APPROXIMATELY 45 MPH, HE NOTICED GASOLINE SPILLING OUT OF THE TANK. PRIOR TO THE SPILL, HE SMELLED A GASOLINE ODOR FOR ABOUT 6 MONTHS. THE VEHICLE WAS INSPECTED BY PEPBOYS WHO INFORMED THE CONTACT THAT THE FUEL TANK SELECTOR NEEDED TO BE REPLACED. THE VIN WAS UNKNOWN. THE VEHICLE WAS REPAIRED. THE FAILURE MILEAGE WAS 38,525.
NHTSA ODI #10366402
50,000 miles · Oct 14, 2010
Fuel System, Gasoline
TL*THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT WHEN HE FILLED THE FRONT TANK, THE FUEL WOULD BE SHIFTED TO THE REAR TANK. THE FAILURE OCCURRED EVERYTIME HE FUELED THE VEHICLE. THE CONTACT STATED THAT BECAUSE OF THE FAILURE, A PRESSURE WAS CREATED WITHIN THE TWO TANKS. THE VEHICLE. THE CONTACT CALLED THE DEALERSH…
Read full complaint
TL*THE CONTACT OWNS A 1991 FORD F-250. THE CONTACT STATED THAT WHEN HE FILLED THE FRONT TANK, THE FUEL WOULD BE SHIFTED TO THE REAR TANK. THE FAILURE OCCURRED EVERYTIME HE FUELED THE VEHICLE. THE CONTACT STATED THAT BECAUSE OF THE FAILURE, A PRESSURE WAS CREATED WITHIN THE TWO TANKS. THE VEHICLE. THE CONTACT CALLED THE DEALERSHIP AND REFERENCED RECALL 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY) AND WAS TOLD THAT THERE WERE NO ACTIVE RECALLS ON HIS VEHICLE. THE CONTACT CALLED THE MANUFACTURER WHO VERIFIED THAT THERE WERE NO ACTIVE RECALLS FOR THE VEHICLE. THE VEHICLE HAD NOT BEEN REPAIRED. THE CURRENT MILEAGE WAS APPROXIMATELY 250,000. THE FAILURE MILEAGE WAS APPROXIMATELY 50,000.
NHTSA ODI #10360519
80,150 miles · Dec 6, 2005
Fuel System, Gasoline
DAD: THE CONTACT STATES THERE IS NHTSA RECALL CAMPAIGN 93V125000 CONCERNING THE FUEL SYSTEM: TANK ASSEMBLY. THIS VEHICLE HAS THE SAME PROBLEMS AS INDICATED IN THE RECALL, BUT II IS NOT INCLUDED IN THE RECALL DUE TO VIN. THE CONTACT REPAIRED THE VEHICLE AT HIS OWN EXPENSE. *AK THE DEALER CHARGED THE CONSUMER 500.00 TO REPL…
Read full complaint
DAD: THE CONTACT STATES THERE IS NHTSA RECALL CAMPAIGN 93V125000 CONCERNING THE FUEL SYSTEM: TANK ASSEMBLY. THIS VEHICLE HAS THE SAME PROBLEMS AS INDICATED IN THE RECALL, BUT II IS NOT INCLUDED IN THE RECALL DUE TO VIN. THE CONTACT REPAIRED THE VEHICLE AT HIS OWN EXPENSE. *AK THE DEALER CHARGED THE CONSUMER 500.00 TO REPLACE THE FUEL PUMP WHICH WAS DIFFERENT FROM THE RECALL. UPDATED 01/11/06. *JB
NHTSA ODI #10144562
Mileage unknown · May 5, 2004
Fuel System, Gasoline
AFTER FUELING THE VEHICLE, CONSUMER NOTICED GAS BEING PUMPED OUT OF THE FRONT FILL POINT LIKE A FIRE HOSE. *PH THIS WAS THE THIRD FAILURE WITH THE CROSSOVER. CONSUMER THEN LEARNED THAT THIS FAILURE WASN'T GOING TO BE COVERED UNDER THE EXTENDED WARRANTY LIKE THE FIRST TWO. *PH
NHTSA ODI #10071875
94,177 miles · Dec 9, 2003
Fuel System, Gasoline
THE GASOLINE WAS NOT TRANSFERRING BETWEEN THE FUEL TANKS, CAUSING VEHICLE TO STALL DUE TO LOW GASOLINE. THE DEALER REPLACED THE FUEL TANK SENDER AND THE FUEL PUMP. *AK THERE WERE FOUR ATTEMPTS TO REMEDY THE TRANSFERRING OF FUEL FROM THE REAR TANK TO THE FRONT TANK THROUGHOUT THE FILLER CAP AND CAUSED LEAKAGE. THE CONSUMER…
Read full complaint
THE GASOLINE WAS NOT TRANSFERRING BETWEEN THE FUEL TANKS, CAUSING VEHICLE TO STALL DUE TO LOW GASOLINE. THE DEALER REPLACED THE FUEL TANK SENDER AND THE FUEL PUMP. *AK THERE WERE FOUR ATTEMPTS TO REMEDY THE TRANSFERRING OF FUEL FROM THE REAR TANK TO THE FRONT TANK THROUGHOUT THE FILLER CAP AND CAUSED LEAKAGE. THE CONSUMER REQUESTED THAT FORD COVER THE CHARGES. *SC *JB
NHTSA ODI #10046352
111,046 miles · Jul 28, 2003
Fuel System, Gasoline
WHEN THE FRONT TANK WAS EMPTY AND THE CONSUMER SWITCHED TO THE REAR FULL TANK, SOMEHOW THE GAS FROM THE REAR TANK PUMPED BACK INTO THE FRONT TANK WHICH RESULTED IN THE REAR TANK BEING EMPTY. *NLM *CB *NLM
NHTSA ODI #10017807
Mileage unknown · Oct 25, 2001
Fuel System, Gasoline
VEHICLE WAS EXAMINED BY THE DEALERSHIP FOR RECALL CAMPAIGN 01I008000 CONCERNING FUEL CROSSOVER. AFTER REPAIR WORK WAS PERFORMED, PROBLEM BECAME WORSE THAN IT HAD BEEN BEFORE DEALER MADE ADJUSTMENTS TO VEHICLE. POWER FAILURE OCCURS, THE MOTOR SHUTS DOWN AS IF IDLING. *JG *AK
NHTSA ODI #898195
Mileage unknown · Feb 27, 2001
Fuel System, Gasoline
WHEN SWITCHING FROM FRONT TANK TO REAR TANK THERE IS A LEAK PRESENT DUE TO FUEL LINE CLAMP THAT DOES NOT HOLD LINES SECURE. DEALER HAS NOT SEEN VEHICLE. *AK
NHTSA ODI #881546
Mileage unknown · Feb 9, 2001
Fuel System, Gasoline
EA 99032 FUEL TANK IS OVERFLOWING REGARDLESS OF WHICH TANK IS ON. FUEL IS STILL BEING USED BY BOTH TANKS. *AK REAR TANK OVERFLOWED WHILE VEHICLE WAS PARKED IN DRIVEWAY.. *SLC
NHTSA ODI #880255
Official recalls
5Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Apr 27, 1993
KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.
Consequence & remedy
Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.
Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93022 · Idle Air Spd Ctrl Vlv Malf
Opened Jul 30, 1993 · Closed Aug 31, 1994
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
PE93010 · Idle Air Spd Ctrl Vlv Malf
Opened Mar 2, 1993 · Closed Jul 30, 1993
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available