← New search

1995 Cadillac Seville

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Seville years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

27 reports with mileage · 47 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Air Bags. Review the 9 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

4 crash reports10 fire reports3 injury reports

Fuel System, Gasoline complaints

20 reports
Clear category filter
Mileage unknown · Nov 9, 2004
Fuel System, Gasoline

THE NYLON TUBING ON THE FUEL RAIL BROKE WHICH CAUSED FUEL TO LEAK FROM THE VEHICLE. *NM FOUR REPAIR SHOPS COULD NOT LOCATE THERE LOSS OF FUEL. RECALL# 04V110000. *SC

NHTSA ODI #10101435

170,000 miles · Oct 15, 2004
Fuel System, Gasoline

CONSUMER STATED THE FUEL RAIL LEAKED. *AK GM STATED THEY WERE NOT GOING TO REIMBURSE THE CONSUMER BECAUSE HE DID NOT HAVE THE RECEIPT. *JB

NHTSA ODI #10090145

Mileage unknown · Aug 27, 2004
Fuel System, Gasoline

CONCERNS WITH FUEL RAIL PROBLEM THAT MAY CAUSE ENGINE FIRE.*MR CONSUMER RECEIVED A RECALL FOR THE FUEL RAIL AND RECEIVED AN APPOINTMENT FOR FRIDAY, AUGUST 13, 2004 TO HAVE THE RECALL PERFORMED. WHEN THE CONSUMER ARRIVED, HE LEARNED THE REPAIR SHOP WERE ALL OUT OF THE REPLACEMENT PARTS. *PH

NHTSA ODI #10091784

92,000 miles · Aug 11, 2004
Fuel System, Gasoline

DURING AN INSPECTION IT WAS DISCOVERED THAT FUEL TANK AND LINE RUSTED, MECHANIC STATED THAT THIS WAS A SAFETY ISSUE. THE FUEL TANK WAS PLASTIC, AND THE GAS LINE WAS METAL.*AK

NHTSA ODI #10087720

113,548 miles · Jul 6, 2004
Fuel System, Gasoline

WHILE DRIVING THERE WAS A GAS ODOR INSIDE THE CABIN OF THE VEHICLE. THE CONSUMER TOOK THE VEHICLE TO A MECHANIC, WHO DETERMINED THAT THERE WAS A CRACK INNER TUBING WHICH CAUSED A LEAK. THERE WAS 2 GALLONS OF GAS UNDERNEATH THE ENGINE COVER. RECALL 04V11000 WAS ISSUED ON THIS PROBLEM, BUT THE VEHICLE IDENTIFICATION NUMBER WAS …

Read full complaint

WHILE DRIVING THERE WAS A GAS ODOR INSIDE THE CABIN OF THE VEHICLE. THE CONSUMER TOOK THE VEHICLE TO A MECHANIC, WHO DETERMINED THAT THERE WAS A CRACK INNER TUBING WHICH CAUSED A LEAK. THERE WAS 2 GALLONS OF GAS UNDERNEATH THE ENGINE COVER. RECALL 04V11000 WAS ISSUED ON THIS PROBLEM, BUT THE VEHICLE IDENTIFICATION NUMBER WAS NOT INCLUDED IN THE RECALL. *JB

NHTSA ODI #10075525

Mileage unknown · Jan 29, 2004
Fuel System, Gasoline

1995 CADILLAC - I SMELLED A STRONG ODOR OF GASOLINE. AFTER TAKING TO SERVICE STATION, THEY DIAGNOSED AS A FAULTY FUEL RAIL SYSTEM, AND THE REPAIR WAS BOTH EXPENSIVE AND THE PROBLEM A DANGEROUS ONE.*AK

NHTSA ODI #10055165

100,000 miles · Jan 23, 2004
Fuel System, Gasoline

THE VEHICLE EXPERIENCED A GAS LEAK. THE GAS LINE THAT GOES TO THE ENGINE IS PLASTIC AND GAS FUMES LEAKED THROUGH THE VENTS. PROVIDE FURTHER DETAILS. *JB

NHTSA ODI #10055789

73,000 miles · Nov 4, 2003
Fuel System, Gasoline

A SMELL OF GASOLINE ENTERED THE PASSENGER CABIN. VEHICLE WAS IMMEDIATELY TAKEN TO THE DEALER, WHO FOUND THAT THE FUEL RAIL WAS LEAKING GASOLINE, AND DEALER REPLACED THE FUEL RAIL. *AK

NHTSA ODI #10046340

62,890 miles · Aug 1, 2003
Engine And Engine CoolingExterior LightingFuel System, Gasoline

WHILE DRIVING THE CONSUMER SMELLED FUEL. THE FUEL RAIL DEVELOPED A LEAK, AND FUEL LEAKED ALL OVER THE ENGINE COMPARTMENT. *AK THE FUEL RAIL CROSS OVER PIPE BETWEEN THE FUEL INJECTORS, DEVELOPED A PRESSURE FUEL LEAK, AS A RESULT THE FUEL SPRAYED ONTO THE ENGINE. GM CLAIMED TO HAVE NO RECORD OF THE PROBLEM. WHEN THE CONSUMER…

Read full complaint

WHILE DRIVING THE CONSUMER SMELLED FUEL. THE FUEL RAIL DEVELOPED A LEAK, AND FUEL LEAKED ALL OVER THE ENGINE COMPARTMENT. *AK THE FUEL RAIL CROSS OVER PIPE BETWEEN THE FUEL INJECTORS, DEVELOPED A PRESSURE FUEL LEAK, AS A RESULT THE FUEL SPRAYED ONTO THE ENGINE. GM CLAIMED TO HAVE NO RECORD OF THE PROBLEM. WHEN THE CONSUMER PICKED UP THE VEHICLE FROM THE DEALER, HE NOTICED THE DEALER HADN'T INSTALLED THE IDENTICAL PART. THE DEALER STATED GM CHANGED THE PART DUE TO PROBLEMS WITH THE FUEL RAIL. THERE WAS A NOISE IN THE ENGINE AREA DUE TO A FAILED WATER PUMP. THE TAIL LAMP BULBS FAILED ALSO. *SCC *JB

NHTSA ODI #10026867

Mileage unknown · Sep 9, 1995
Fuel System, Gasoline

FUEL PUMP WAS REPLACED THREE TIMES, VEHICLE WOULD DIE OUT. TT

NHTSA ODI #971914

Official recalls

2

04V110000 · Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

Mar 4, 2004

SOME PASSENGER VEHICLES EQUIPPED WITH 4.0L V8 ENGINES HAVE A CONDITION IN WHICH THE NYLON TUBING USED IN THE FUEL RAIL CONSTRUCTION MAY DEGRADE AND CRACK. ADDITIONALLY, THE 1995 MODEL YEAR USES A UNIQUE UNDERHOOD FUEL RETURN LINE THAT MAY CRACK. CRACKING OF THE FUEL RAIL OR RETURN LINE TUBING CAN RESULT IN A FUEL LEAK INTO THE ENGINE COMPARTMENT.

Consequence & remedy

Consequence: FUEL LEAKAGE, IN THE PRESENCE OF AN IGNITION SOURCE, COULD RESULT IN A FIRE.

Remedy: DEALERS WILL INSPECT AND, IF NECESSARY, REPLACE THE ENGINE FUEL RAIL WITH A NEW STAINLESS STEEL FUEL RAIL. DEALERS WILL ALSO INSTALL A REVISED CHASSIS FUEL RETURN LINE. THE RECALL BEGAN ON JUNE 2, 2004, FOR 1996-1997 OLDSMOBILE AURORA VEHICLES. OWNERS OF 1995 CADILLACS AND 1996-1997 OLDSMOBILE AURORA WERE SENT LETTERS ON AUGUST 6, 2004. ADDITIONAL LETTERS TO OWNERS WILL BE FORTHCOMING. OWNERS SHOULD CONTACT OLDSMOBILE AT 1-800-630-6537.

98V115000 · Air Bags

May 26, 1998

VEHICLE DESCRIPTION: PASSENGER VEHICLES. INADVERTENT DEPLOYMENT OF THE AIR BAGS CAN OCCUR DUE TO WATER INTRUSION.

Consequence & remedy

Consequence: DEPLOYMENT OF THE AIR BAG WITHOUT WARNING COULD CAUSE A DRIVER TO LOSE VEHICLE CONTROL INCREASING THE RISK OF A VEHICLE CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL CLEAN THE EXTERIOR CASE OF THE SENSING AND DIAGNOSTIC MODULE (SDM) AND APPPLY A POTTING COMPOUND TO THE SDM CASE AND ELECTRICAL CONNECTOR BODY.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

4

EA04003 · Fuel Rail Leaks

Opened Feb 3, 2004 · Closed Apr 23, 2004

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:fuel Injection System:fuel Rail

ON MARCH 3, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS RECALLING APPROXIMATELY 94,000 MY 1995-97 OLDSMOBILE AURORA VEHICLES EQUIPPED WITH 4.0L V8 ENGINES (RPO L47 - VIN8 C) TO ADDRESS CONCERNS WITH UNDERHOOD FUEL LEAKAGE FROM CRACKED FUEL RAILS AND, IN SOME OF THE VEHICLES, CRACKED FUEL RETURN LINES. ACCORDING TO GM, THE NYLON TUBING (PA12) USED IN THE FUEL RAIL CONSTRUCTION IN THESE VEHICLES MAY DEGRADE AND CRACK.GM'S SUPPLIER ATTRIBUTED THE CRACKING TO THE COMBINED EFFECTS OF HEAT, TIME, ALCOHOL FUEL, FUEL PRESSURE CYCLING, AND DESIGN STRESSES.IN ADDITION, GM STATED THAT THE MY 1995 AURORA USES A UNIQUE UNDERHOOD FUEL RETURN LINE THAT MAY ALSO CRACK AT UNUSUALLY HIGH RATES.GM DEALERS WILL INSTALL A NEW FUEL RAIL CONSTRUCTED OUT OF STAINLESS STEEL IN ALL OF THE RECALLED VEHICLES AND WILL ALSO INSTALL A REVISED CHASSIS FUEL RETURN LINE IN THE MY 1995 AURORAS. ON APRIL 16, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS ADDING APPROXIMATELY 389,000 MY 1995-97 CADILLAC SEVILLE, DEVILLE AND ELDORADO VEHICLES EQUIPPED WITH 4.6L V8 ENGINES (RPO'S LD8 AND L37 - VIN8 Y AND 9) TO RECALL 04V-110.THE RECALLED CADILLACS WILL RECEIVE THE NEW STAINLESS STEEL FUEL RAILS.THIS ENGINEERING ANALYSIS IS CLOSED.

Additional source detail variants (3)

Fuel System, Gasoline:delivery

ON MARCH 3, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS RECALLING APPROXIMATELY 94,000 MY 1995-97 OLDSMOBILE AURORA VEHICLES EQUIPPED WITH 4.0L V8 ENGINES (RPO L47 - VIN8 C) TO ADDRESS CONCERNS WITH UNDERHOOD FUEL LEAKAGE FROM CRACKED FUEL RAILS AND, IN SOME OF THE VEHICLES, CRACKED FUEL RETURN LINES. ACCORDING TO GM, THE NYLON TUBING (PA12) USED IN THE FUEL RAIL CONSTRUCTION IN THESE VEHICLES MAY DEGRADE AND CRACK.GM'S SUPPLIER ATTRIBUTED THE CRACKING TO THE COMBINED EFFECTS OF HEAT, TIME, ALCOHOL FUEL, FUEL PRESSURE CYCLING, AND DESIGN STRESSES.IN ADDITION, GM STATED THAT THE MY 1995 AURORA USES A UNIQUE UNDERHOOD FUEL RETURN LINE THAT MAY ALSO CRACK AT UNUSUALLY HIGH RATES.GM DEALERS WILL INSTALL A NEW FUEL RAIL CONSTRUCTED OUT OF STAINLESS STEEL IN ALL OF THE RECALLED VEHICLES AND WILL ALSO INSTALL A REVISED CHASSIS FUEL RETURN LINE IN THE MY 1995 AURORAS. ON APRIL 16, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS ADDING APPROXIMATELY 389,000 MY 1995-97 CADILLAC SEVILLE, DEVILLE AND ELDORADO VEHICLES EQUIPPED WITH 4.6L V8 ENGINES (RPO'S LD8 AND L37 - VIN8 Y AND 9) TO RECALL 04V-110.THE RECALLED CADILLACS WILL RECEIVE THE NEW STAINLESS STEEL FUEL RAILS.THIS ENGINEERING ANALYSIS IS CLOSED.

Fuel System, Gasoline:fuel Injection System:fuel Rail

ON MARCH 3, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS RECALLING APPROXIMATELY 94,000 MY 1995-97 OLDSMOBILE AURORA VEHICLES EQUIPPED WITH 4.0L V8 ENGINES (RPO L47 - VIN8 C) TO ADDRESS CONCERNS WITH UNDERHOOD FUEL LEAKAGE FROM CRACKED FUEL RAILS AND, IN SOME OF THE VEHICLES, CRACKED FUEL RETURN LINES. ACCORDING TO GM, THE NYLON TUBING (PA12) USED IN THE FUEL RAIL CONSTRUCTION IN THESE VEHICLES MAY DEGRADE AND CRACK.GM'S SUPPLIER ATTRIBUTED THE CRACKING TO THE COMBINED EFFECTS OF HEAT, TIME, ALCOHOL FUEL, FUEL PRESSURE CYCLING, AND DESIGN STRESSES.IN ADDITION, GM STATED THAT THE MY 1995 AURORA USES A UNIQUE UNDERHOOD FUEL RETURN LINE THAT MAY ALSO CRACK AT UNUSUALLY HIGH RATES.GM DEALERS WILL INSTALL A NEW FUEL RAIL CONSTRUCTED OUT OF STAINLESS STEEL IN ALL OF THE RECALLED VEHICLES AND WILL ALSO INSTALL A REVISED CHASSIS FUEL RETURN LINE IN THE MY 1995 AURORAS. ON APRIL 16, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS ADDING APPROXIMATELY 389,000 MY 1995-97 CADILLAC SEVILLE, DEVILLE AND ELDORADO VEHICLES EQUIPPED WITH 4.6L V8 ENGINES (RPO'S LD8 AND L37 - VIN8 Y AND 9) TO RECALL 04V-110.THE RECALLED CADILLACS WILL RECEIVE THE NEW STAINLESS STEEL FUEL RAILS.THIS ENGINEERING ANALYSIS IS CLOSED.

Fuel System, Gasoline

ON MARCH 3, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS RECALLING APPROXIMATELY 94,000 MY 1995-97 OLDSMOBILE AURORA VEHICLES EQUIPPED WITH 4.0L V8 ENGINES (RPO L47 - VIN8 C) TO ADDRESS CONCERNS WITH UNDERHOOD FUEL LEAKAGE FROM CRACKED FUEL RAILS AND, IN SOME OF THE VEHICLES, CRACKED FUEL RETURN LINES. ACCORDING TO GM, THE NYLON TUBING (PA12) USED IN THE FUEL RAIL CONSTRUCTION IN THESE VEHICLES MAY DEGRADE AND CRACK.GM'S SUPPLIER ATTRIBUTED THE CRACKING TO THE COMBINED EFFECTS OF HEAT, TIME, ALCOHOL FUEL, FUEL PRESSURE CYCLING, AND DESIGN STRESSES.IN ADDITION, GM STATED THAT THE MY 1995 AURORA USES A UNIQUE UNDERHOOD FUEL RETURN LINE THAT MAY ALSO CRACK AT UNUSUALLY HIGH RATES.GM DEALERS WILL INSTALL A NEW FUEL RAIL CONSTRUCTED OUT OF STAINLESS STEEL IN ALL OF THE RECALLED VEHICLES AND WILL ALSO INSTALL A REVISED CHASSIS FUEL RETURN LINE IN THE MY 1995 AURORAS. ON APRIL 16, 2004, GENERAL MOTORS NOTIFIED ODI THAT IT WAS ADDING APPROXIMATELY 389,000 MY 1995-97 CADILLAC SEVILLE, DEVILLE AND ELDORADO VEHICLES EQUIPPED WITH 4.6L V8 ENGINES (RPO'S LD8 AND L37 - VIN8 Y AND 9) TO RECALL 04V-110.THE RECALLED CADILLACS WILL RECEIVE THE NEW STAINLESS STEEL FUEL RAILS.THIS ENGINEERING ANALYSIS IS CLOSED.

PE03050 · Fuel Rail Leakage

Opened Oct 30, 2003 · Closed Feb 3, 2004

Status: closed (inferred from source dates) · Fuel System, Gasoline:fuel Injection System:fuel Rail

THE FUEL RAIL ASSEMBLIES USED IN THE SUBJECT VEHICLES WERE MANUFACTURED BY DANA.THE FUEL RAIL JUMPER TUBES WERE MADE OF MONOLAYER NYLON 12 (PA12).IN MODEL YEAR (MY) 1998, THE JUMPER TUBE MATERIAL WAS CHANGED FROM PA12 TO M-BOND (A MULTI-LAYER PTFE/PA12).IN ADDITION, ALL SERVICE PARTS PRODUCED SINCE THE END OF PRODUCTION 1997 USE THE M-BOND JUMPER TUBES. MATERIAL ANALYSIS PERFORMED BY DANA ON FAILED FUEL RAILS SHOWED THAT THE MONO-LAYER NYLON 12 JUMPER TUBES ARE SUSCEPTIBLE TO ENVIRONMENTAL STRESS CRACKING (ESC).GM BELIEVES THE ESC IS A RESULT OF HEAT, TIME, ALCOHOL BLENDED FUEL, FUEL PRESSURE CYCLING, AND DESIGNED IN STRESS. EIGHT OF THE GM COMPLAINTS ARE DUPLICATIVE OF ODI COMPLAINTS.ODI HAS RECEIVED 77 OF IT'S 123 COMPLAINTS IN THE PAST 12 MONTHS.FUEL RAIL PART SALES OVER THE LAST THREE YEARS RANGE FROM 3.0 PERCENT OF PRODUCTION FOR THE MY 1997 CADILLAC VEHICLES TO 13.1 PERCENT FOR THE MY 1995 AURORAS.AT LEAST ONE OF THE FIRE INCIDENTS OCCURED WHILE THE VEHICLE WAS PARKED WITHIN A GARAGE ATTACHED TO THE CONSUMERS HOME.THE FIRE RESULTED IN DAMAGE TO THE DWELLING AS WELL AS THE TOTAL LOSS OF THE VEHICLE.THIS INVESTIGATION HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS.

EA98004 · Inadvertent Air Bag Deployment

Opened Feb 24, 1998 · Closed Jun 16, 1998

Status: closed (inferred from source dates) · Air Bags

There is no summary currently available

SQ97017 · Inadvertent Air Bag Deployment

Opened Jul 2, 1997 · Closed Feb 24, 1998

Status: closed (inferred from source dates) · Air Bags

IF A 1995 CADILLAC INTERIOR IS EXPOSED TO SIGNIFICANT WATER INTRUSION, SUCH AS FROM WATER LEAKS, A WINDOW LEFT OPEN IN THE RAIN, OR DRIVING THROUGH HIGH WATER UP TO THE CARPET LEVEL, THE SUPPLEMENTAL INFLATABLE RESTRAINT (SIR) SYSTEM SENSING AND DIAGNOSTIC MODULE (SDM) CAN BE DAMAGED.IF THIS OCCURS, BOTH THE DRIVER AND PASSENGER AIR BAGS CAN DEPLOY WHEN THE IGNITION SWITCH IS TURNED ON, EVEN IF THERE HAS BEEN NO FRONTAL IMPACT OR CRASH.AS A RESULT OF THESE DEPLOYMENTS, GM CONDUCTED AN ADVISORY LETTER CAMPAIGN, NUMBER 51-01-08 ENTITLED INADVERTENT DEPLOYMENT OF AIR BAGS WHEN INTERIOR EXPOSED TO WET CONDITIONS, IN FEBRUARY 1996.LETTERS TO OWNERS MAILED PURSUANT TO THIS COMPAIGN WARNED OWNERS TO NOT START THEIR ENGINES IF THE VEHICLE INTERIOR HAD BEEN EXPOSED TO SUBSTANTIAL AMOUNTS OF WATER.ODI HAS RECEIVED A TOTAL 8 REPORTS OF INADVERTENT AIR BAG DEPLOYMENT IN 1995 CADILLAC VEHICLES.