← New search

2009 Blue Bird Vision

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Vision years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 5 of 6 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Diesel. Review the 2 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 1 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Structure. Review the 1 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports1 fire reports0 injury reports

Visibility complaints

1 reports
Clear category filter
68,000 miles · Jan 26, 2010
Visibility

HIGH FAILURE RATE FOR HEATER MOTOR BLOWER CAGE FOR SCHOOLBUS STEP WELL. BLOWER CAGE DESTRUCTS. THIS HAPPENS FREQUENTLY. THIS CREATES A SAFETY DEFECT BECAUSE THE HEAT IS NEEDED TO KEEP STEPS FREE OF ICE AND SNOW. THIS HAS HAPPENED MANY TIMES IN THE LAST YEAR AND PARTS ARE NOT ALWAYS AVAILABLE DUE TO HIGH DEMAND TO REPLACE. *TR

NHTSA ODI #10302333

Official recalls

28

20V234000 · Parking Brake

Apr 27, 2020

Blue Bird Body Company (Blue Bird) is recalling certain 2006-2021 Vision and 2007-2013 All American school buses. The floor-mounted parking brake may fail to hold the vehicle stationary on an incline when the vehicle is loaded to its maximum weight, due to an insufficient application force. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 105, "Hydraulic and Electric Brake Systems."

Consequence & remedy

Consequence: A parking brake system that is set to an insufficient application force may result in an increased possibility of unintended vehicle movement, which increases the risk of a crash.

Remedy: Blue Bird will notify owners, and dealers will inspect the floor mounted park brake application force hand lever assembly and correct the application force, as necessary, free of charge. The recall is expected to begin June 24, 2020. Owners may contact Blue Bird customer service at 478-822-2242. Blue Bird's number for this recall is R20AO-SB.

20V235000 · Parking Brake

Apr 27, 2020

Blue Bird Body Company (Blue Bird) is recalling certain 2009-2019 Vision transit buses. The floor-mounted parking brake may fail to hold the vehicle stationary on an incline when the vehicle is loaded to its maximum weight, due to an insufficient application force. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 105 "Hydraulic and Electric Brake Systems."

Consequence & remedy

Consequence: A parking brake system that is set to an insufficient application force may result in an increased possibility of unintended vehicle movement, which increases the risk of injury to bystanders.

Remedy: Blue Bird will notify owners, and dealers will inspect the floor mounted park brake application force hand lever assembly and adjust the application force, as necessary, free of charge. The recall is expected to begin June 24, 2020. Owners may contact Blue Bird customer service at 478-822-2242. Blue Bird's number for this recall is R20AO-SB.

20V125000 · Seats:barriers

Mar 3, 2020

Blue Bird Body Company (Blue Bird) is recalling certain 2008-2021 Vision and All American school buses. The seat barrier behind the driver seat with an integrated 3-point seat belt may have been installed incorrectly and may be missing the reinforcing bracket. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 222, "School Bus Passenger Seating and Crash Protection."

Consequence & remedy

Consequence: In the event of a crash, the seat barrier may not adequately protect the occupant seated behind the seat barrier separating them from the driver seat with integrated 3-point seat belt, increasing the risk of injury.

Remedy: Blue Bird will notify owners, and dealers will inspect and properly install the seat barrier including adding reinforcing bracket, as necessary, free of charge. The recall is expected to begin April 23, 2020. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's number for this recall is R20AM-SB.

16V100000 · Electrical SYSTEM:12V/24V/48V Battery:cables; Electrical System:starter Assembly; Electrical System:wiring

Feb 23, 2016

Blue Bird Body Company (Blue Bird) is recalling certain model year 2008-2009 Vision school buses manufactured from May 10, 2007, through March 5, 2008 and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence & remedy

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-SB.

Additional source detail variants (3)

Electrical System:wiring

Blue Bird Body Company (Blue Bird) is recalling certain model year 2008-2009 Vision school buses manufactured from May 10, 2007, through March 5, 2008 and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-SB.

Electrical System:starter Assembly

Blue Bird Body Company (Blue Bird) is recalling certain model year 2008-2009 Vision school buses manufactured from May 10, 2007, through March 5, 2008 and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-SB.

Electrical SYSTEM:12V/24V/48V Battery:cables

Blue Bird Body Company (Blue Bird) is recalling certain model year 2008-2009 Vision school buses manufactured from May 10, 2007, through March 5, 2008 and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-SB.

16V101000 · Electrical SYSTEM:12V/24V/48V Battery:cables; Electrical System:starter Assembly; Electrical System:wiring

Feb 23, 2016

Blue Bird Body Company (Blue Bird) is recalling certain model year 2009 Vision transit buses manufactured from November 27, 2007, through February 18, 2008, and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence & remedy

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-NSB.

Additional source detail variants (3)

Electrical System:wiring

Blue Bird Body Company (Blue Bird) is recalling certain model year 2009 Vision transit buses manufactured from November 27, 2007, through February 18, 2008, and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-NSB.

Electrical System:starter Assembly

Blue Bird Body Company (Blue Bird) is recalling certain model year 2009 Vision transit buses manufactured from November 27, 2007, through February 18, 2008, and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-NSB.

Electrical SYSTEM:12V/24V/48V Battery:cables

Blue Bird Body Company (Blue Bird) is recalling certain model year 2009 Vision transit buses manufactured from November 27, 2007, through February 18, 2008, and equipped with Caterpillar C707 engines. In the affected buses, the positive starter cable may be incorrectly attached to the same Power Distribution Unit (PDU) stud as the battery cable, exposing the smaller battery cable to a higher current draw during cranking.

Consequence: Exposure to high current draw may cause the battery cable to overheat, melt the wire insulation and increase the risk of a short circuit and a fire.

Remedy: Blue Bird will notify owners, and dealers will relocate the starter cable to the chassis power stud. Any damaged battery cables will be replaced. These repairs will be made free of charge. The recall began on March 10, 2016. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's recall number for this campaign is R16YL-NSB.

15V730000 · Equipment Adaptive/mobility

Nov 4, 2015

Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American, Vision, 2007-2011 Micro Bird, and 2007-2008 Conventional school buses, equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured January 1, 2006, to August 25, 2014 by the Ricon Corporation. The affected lifts are equipped with folding link arms that may have pivot holes that are too big, allowing the bearings to move out of position.

Consequence & remedy

Consequence: If the bearings move out of position, the stowed platform may have excessive movement resulting in failure of the platform mounting. This failure could cause the wheel chair lift platform to fall out of the vehicle when the doors are opened, increasing the risk of injury for the lift operator.

Remedy: Blue Bird will notify owners, and Ricon dealers will inspect the link arms for damage or for displaced bearings. The platform will be inspected for cracks. Any damaged parts will be replaced, free of charge. The recall began on December 1, 2015. Owners may contact Blue Bird customer service at 1-478-822-2242, or Ricon Customer Service at 1-800-322-2884.

15V731000 · Equipment Adaptive/mobility

Nov 4, 2015

Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American and Vision and 2007-2011 Micro Bird transit buses equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured January 1, 2006, to August 25, 2014 by the Ricon Corporation. The affected lifts are equipped with folding link arms that may have pivot holes that are too big, allowing the bearings to move out of position.

Consequence & remedy

Consequence: If the bearings move out of position, the stowed platform may have excessive movement resulting in failure of the platform mounting. This failure could cause the wheel chair lift platform to fall out of the vehicle when the doors are opened, increasing the risk of injury for the lift operator.

Remedy: Blue Bird will notify owners, and Ricon dealers will inspect the link arms for damage or for displaced bearings. The platform will be inspected for cracks. Any damaged parts will be replaced, free of charge. The recall began on December 1, 2015. Owners may contact Blue Bird customer service at 1-478-822-2242, or Ricon Customer Service at 1-800-322-2884.

14V510000 · Equipment Adaptive/mobility

Aug 19, 2014

Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American and Vision, 2007-2011 Micro Bird, and 2007-2008 Conventional school buses equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon Corporation. The platform side plate of the affected wheelchair lifts may crack.

Consequence & remedy

Consequence: If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.

Remedy: Blue Bird will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on October 1, 2014. Owners may contact Blue Bird customer service at 1-478-822-2242 or Ricon customer service at 1-800-322-2884. Blue Bird's number for this recall is R14XN.

14V511000 · Equipment Adaptive/mobility

Aug 19, 2014

Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American, 2007-2010 Micro Bird, and 2007-2014 Vision non-school buses equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon Corporation. The platform side plate of the affected wheelchair lifts may crack.

Consequence & remedy

Consequence: If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.

Remedy: Blue Bird will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on October 1, 2014. Owners may contact Blue Bird customer service at 1-478-822-2242 or Ricon customer service at 1-800-322-2884. Blue Bird's number for this recall is R14XN.

13V332000 · Structure

Jul 31, 2013

Blue Bird Body Company is recalling certain model year 2007-2014 All American and Vision school buses manufactured March 10, 2006, through June 18, 2013; and equipped with optional transit sliding windows. Joint adhesive may not have been applied at the interior and exterior body window panel joints. Without the adhesive, these vehicles fail to conform to the standards of Federal Motor Vehicle Safety Standard (FMVSS) No. 221, "School Bus Body Joint Strength."

Consequence & remedy

Consequence: In the event of a vehicle crash, there is an increased risk that the window panels may separate and fall onto occupants causing injury.

Remedy: Blue Bird will notify owners, and dealers will install additional rivets at the window panel joints, free of charge. The recall began on August 28, 2013. Owners may contact Blue Bird at 1-478-825-2021. Blue Bird's recall number is R13WM.

12V153000 · Equipment Adaptive/mobility

Apr 5, 2012

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2009 THROUGH 2011 ALL AMERICAN, VISION, AND MICRO BIRD SCHOOL BUSES EQUIPPED WITH BRAUN VISTA-2 WHEELCHAIR LIFTS. OVER TIME AND WITH FREQUENT USE, THE ROLL STOP LATCHES ON THE OUTER BARRIER MAY BECOME BENT OR MISALIGNED.

Consequence & remedy

Consequence: A WHEELCHAIR OCCUPANT MAY DEFEAT OR RIDE OVER THE INSUFFICIENTLY LATCHED ROLL STOP. IF THIS OCCURS WHEN THE LIFT PLATFORM IS IN AN ELEVATED POSITION, THE WHEELCHAIR’S OCCUPANT COULD FALL AND SUSTAIN INJURY.

Remedy: BLUE BIRD WILL NOTIFY OWNERS, AND THE REPAIRS WILL BE PERFORMED BY AUTHORIZED BRAUN DEALERS FREE OF CHARGE. THE SAFETY RECALL BEGAN ON APRIL 26, 2012. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

11V499000 · Seats:barriers

Oct 14, 2011

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2006 THROUGH 2012 ALL AMERICAN, 2006 THROUGH 2011 VISION, AND 2006 CONVENTIONAL SCHOOL BUSES MANUFACTURED BETWEEN SEPTEMBER 19, 2005, AND MAY 3, 2011, EQUIPPED WITH 2-PASSENGER SEATS INSTALLED FORWARD OF THE 39" BARRIER. IN THE EVENT OF A CRASH, THE BARRIER MAY MAKE CONTACT WITH THE 2-PASSENGER SEAT INSTALLED FORWARD OF THE BARRIER. ACCORDINGLY, THESE BUSES FAIL TO CONFORM WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 222, "SCHOOL BUS PASSENGER SEATING AND CRASH PROTECTION."

Consequence & remedy

Consequence: THE SEAT OCCUPANTS MAY BE SERIOUSLY INJURED IN THE EVENT OF A CRASH.

Remedy: BLUE BIRD WILL NOTIFY OWNERS, AND DEALERS WILL REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JANUARY 18, 2012. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

11V247000 · Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

Apr 22, 2011

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2009 THROUGH 2012 VISION SCHOOL BUSES MANUFACTURED FROM OCTOBER 7, 2008, THROUGH JANUARY 19, 2011, EQUIPPED WITH AN OPTIONAL FUEL FILTER LOCATED ON THE DRIVER'S CONTROL MODULE. DUE TO ROUTING AND CLAMPING VARIATIONS, THE FUEL LINE ON UNITS EQUIPPED WITH AN OPTIONAL RELOCATED FUEL FILTER MAY CONTACT THE BODY MOUNTED TRANSMISSION COVER AND CHAFE AGAINST THE COVER.

Consequence & remedy

Consequence: THIS CONDITION COULD POTENTIALLY RESULT IN A FUEL LEAK AND POSSIBLY RESULT IN A FIRE.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND DEALERS WILL INSPECT FOR CONTACT/RUBBING WITH THE TRANSMISSION COVER. FUEL LINES FOUND TO BE CONTACTING OR RUBBING WILL BE REPOSITIONED. ANY DAMAGED FUEL FILTER HOSES FOUND WILL BE REPLACED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MAY 25, 2011. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

11V174000 · Electrical System: Instrument Cluster/panel

Mar 15, 2011

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2007 THROUGH 2011 VISION SCHOOL BUSES. THE DASH INSTRUMENT PANEL ABS INDICATOR LIGHT DOES NOT ILLUMINATE WHEN THE ABS CIRCUIT IS DISCONNECTED AT THE MAIN ABS MODULE. ACCORDINGLY, THESE BUSES FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS," AND FMVSS NO. 121, "AIR BRAKE SYSTEMS."

Consequence & remedy

Consequence: IN THE EVENT THE ABS CIRCUIT DISCONNECTS FROM THE MAIN ABS MODULE, THE BUS OPERATOR WOULD BE UNAWARE OF THE FAILURE OF THE ABS SYSTEM AND THE ASSOCIATED REDUCED BRAKING FUNCTION, INCREASING THE RISK OF A CRASH.

Remedy: BLUE BIRD IS CURRENTLY WORKING WITH STONERIDGE TO PRODUCE SOFTWARE THAT DEALERS CAN USE TO REPROGRAM THE DASH INSTRUMENT PANEL. BLUE BIRD WILL NOTIFY OWNERS ONCE THE SOFTWARE UPDATE BECOMES AVAILABLE. THE AFFECTED BUSES WILL BE REPAIRED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JUNE 23, 2011. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

11V175000 · Electrical System: Instrument Cluster/panel

Mar 15, 2011

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2008 THROUGH 2010 VISION NON SCHOOL BUSES. THE DASH INSTRUMENT PANEL ABS INDICATOR LIGHT DOES NOT ILLUMINATE WHEN THE ABS CIRCUIT IS DISCONNECTED AT THE MAIN ABS MODULE. ACCORDINGLY, THESE BUSES FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS," AND FMVSS NO. 121, "AIR BRAKE SYSTEMS."

Consequence & remedy

Consequence: IN THE EVENT THE ABS CIRCUIT DISCONNECTS FROM THE MAIN ABS MODULE, THE BUS OPERATOR WOULD BE UNAWARE OF THE FAILURE OF THE ABS SYSTEM AND THE ASSOCIATED REDUCED BRAKING FUNCTION, INCREASING THE RISK OF A CRASH.

Remedy: BLUE BIRD IS CURRENTLY WORKING WITH STONERIDGE TO PRODUCE SOFTWARE THAT DEALERS CAN USE TO REPROGRAM THE DASH INSTRUMENT PANEL. BLUE BIRD WILL NOTIFY OWNERS ONCE THE SOFTWARE UPDATE BECOMES AVAILABLE. THE AFFECTED BUSES WILL BE REPAIRED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JUNE 23, 2011. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

10V289000 · Engine And Engine Cooling

Jun 28, 2010

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2008 THROUGH 2010 ALL AMERICAN AND VISION MODEL SCHOOL BUSES MANUFACTURED FROM MAY 23, 2007 THROUGH MARCH 9, 2010, EQUIPPED WITH CATERPILLAR C7 ENGINES. THE #5 AND #6 FUEL LINES MAY CRACK AT THE FASTENING POINT TO THE COMMON FUEL RAIL AND CAUSE A FUEL LEAK.

Consequence & remedy

Consequence: A FUEL LEAK, IN THE PRESENCE OF AN IGNITION SOURCE, CAN RESULT IN A VEHICLE FIRE.

Remedy: BLUE BIRD IS WORKING WITH CATERPILLER TO NOTIFY OWNERS AND REPAIRS WILL BE PERFORMED BY AUTHORIZED CATERPILLAR DEALERS FREE OF CHARGE. OWNERS MAY CONTACT CATERPILLAR TOLL-FREE AT 1-800-447-4986 OR BLUE BIRD AT 1-478-822-2242.

10V290000 · Engine And Engine Cooling

Jun 28, 2010

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2008 THROUGH 2010 ALL AMERICAN, VISION, AND EXCEL 102 MODEL NON SCHOOL BUSES MANUFACTURED FROM MAY 17, 2007 THROUGH NOVEMBER 13, 2008, EQUIPPED WITH CATERPILLAR C7 ENGINES. THE #5 AND #6 FUEL LINES MAY CRACK AT THE FASTENING POINT TO THE COMMON FUEL RAIL AND CAUSE A FUEL LEAK.

Consequence & remedy

Consequence: A FUEL LEAK, IN THE PRESENCE OF AN IGNITION SOURCE, CAN RESULT IN A VEHICLE FIRE.

Remedy: BLUE BIRD IS WORKING WITH CATERPILLAR TO NOTIFY OWNERS AND REPAIRS WILL BE PERFORMED BY AUTHORIZED CATERPILLAR DEALERS FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 9, 2010. OWNERS MAY CONTACT CATERPILLAR TOLL-FREE AT 1-800-447-4986 OR BLUE BIRD AT 1-478-822-2242.

10V169000 · Electrical System

Apr 23, 2010

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2004 THROUGH 2009 VISION SCHOOL BUSES MANUFACTURED FROM JANUARY 30, 2003 THROUGH SEPTEMBER 24, 2008. THE POWER CABLES RUNNING TO THE POWER DISTRIBUTION UNIT STUD AND DRIVER'S CONTROL MODULE STUD MAY HAVE BEEN INSTALLED WITH THE LUG (EYELET) FLAT SIDE UP. WHEN THIS CONDITION EXISTS, VIBRATION MAY WEAR THE INSULATION PERMITTING DIRECT CONTACT BETWEEN THE BARE LUG AND THE PDU OR DCM WHICH COULD CAUSE A DIRECT SHORT IN THE ELECTRICAL SYSTEM.

Consequence & remedy

Consequence: THIS CONDITION COULD RESULT IN A FIRE.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND REPAIR THE BUSES AS NECESSARY FREE OF CHARGE. THE SAFETY RECALL BEGAN MAY 26, 2020. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

10V170000 · Electrical System

Apr 23, 2010

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2004 THROUGH 2009 VISION NON-SCHOOL BUSES MANUFACTURED FROM SEPTEMBER 19, 2003 THROUGH JULY 2, 2008. THE POWER CABLES RUNNING TO THE POWER DISTRIBUTION UNIT STUD AND DRIVER'S CONTROL MODULE STUD MAY HAVE BEEN INSTALLED WITH THE LUG (EYELET) FLAT SIDE UP. WHEN THIS CONDITION EXISTS, VIBRATION MAY WEAR THE INSULATION PERMITTING DIRECT CONTACT BETWEEN THE BARE LUG AND THE PDU OR DCM WHICH COULD CAUSE A DIRECT SHORT IN THE ELECTRICAL SYSTEM.

Consequence & remedy

Consequence: THIS CONDITION COULD RESULT IN A FIRE.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND REPAIR THE BUSES AS NECESSARY FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MAY 26, 2020. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

09V335000 · Other:school Bus Stop Arm Assembly

Aug 25, 2009

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2008 AND 2009 ALL AMERICAN, VISION, AND MICRO BIRD SCHOOL BUSES MANUFACTURED BETWEEN APRIL 18, 2008 AND FEBRUARY 11, 2009, EQUIPPED WITH SPECIALTY MANUFACTURING, INC. (SMI) 000290 LED LIGHT KITS. A CHANGE TO THE WIRE USED IN THE LED LIGHT KITS MAY REDUCE THE EFFECTIVE LIFE OF THE LIGHTS USED ON THE STOP ARMS. THE LIGHTS MAY STOP FUNCTIONING WITHOUT WARNING.

Consequence & remedy

Consequence: SHOULD THE LED LIGHTS STOP FUNCTIONING, VISIBILITY OF A STOPPED BUS WOULD BE DECREASED, POSSIBLY ENDANGERING A CHILD OR PEDESTRIAN TO INJURY BY PASSING VEHICLES.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND THE BUSES WILL BE REPAIRED FREE OF CHARGE. REPAIRS WILL BE PERFORMED BY SMI. THE SAFETY RECALL BEGAN ON SEPTEMBER 24, 2009. OWNERS MAY CONTACT SMI WARRANTY SERVICE AT 1-800-951-7867 OR BLUE BIRD AT 1-478-822-2242.

09V328000 · Seats

Aug 13, 2009

BLUE BIRD IS RECALLING CERTAIN MODEL YEAR 2004 THROUGH 2010 ALL AMERICAN, VISION, MICRO BIRD, AND CONVENTIONAL SCHOOL BUSES MANUFACTURED BETWEEN JANUARY 30, 2003 AND MAY 7, 2009. INCORRECT OFFSET LEG BARRIER PADS OR 2/3 SEAT BACK PADS MAY HAVE BEEN INSTALLED. BUSES WITH INCORRECT PADS INSTALLED FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 222, "SCHOOL BUS PASSENGER SEATING AND CRASH PROTECTION."

Consequence & remedy

Consequence: IN THE EVENT OF A CRASH, THERE IS AN INCREASED RISK OF INJURY TO THE SEAT OCCUPANT(S).

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND THE BUSES WILL BE REPAIRED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 18, 2009. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

09V284000 · Steering:hydraulic Power Assist System

Jul 23, 2009

BLUE BIRD IS RECALLING 7,772 MODEL YEAR 2008 THROUGH 2010 VISION SCHOOL BUSES MANUFACTURED FROM MARCH 27, 2007 THROUGH JUNE 10, 2009. THE LID GASKET ON THE POWER STEERING RESERVOIR MAY DETERIORATE AND CONTAMINATE THE POWER STEERING FLUID WHICH COULD RESULT IN A LOSS OF POWER STEERING ASSIST.

Consequence & remedy

Consequence: LOSS OF POWER STEERING ASSIST COULD RESULT IN A VEHICLE CRASH.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL CAMPAIGN BEGAN ON AUGUST 11, 2009. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

09V251000 · Seats

Jul 6, 2009

BLUE BIRD IS RECALLING 69 MODEL YEAR 2008 THROUGH 2010 MICRO BIRD AND VISION SCHOOL BUSES MANUFACTURED FROM SEPTEMBER 29, 2007 THROUGH MAY 2, 2009, EQUIPPED WITH OPTIONAL 34 INCH OFFSET BARRIER. THE OFFSET LEG OF THE BARRIER FRAME MAY HAVE BEEN LOCATED INCORRECTLY AND INCORRECT PADDING MAY HAVE BEEN INSTALLED ON THE 34 INCH OFFSET BARRIERS WHICH FAILS TO COMPLY WITH THE LEG PROTECTION ZONE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 222, "SCHOOL BUS PASSENGER SEATING AND CRASH PROTECTION."

Consequence & remedy

Consequence: VEHICLE OCCUPANTS MAY SUFFER INJURIES IN THE EVENT OF A VEHICLE CRASH.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND REPLACE THE BARRIER PADS WITH A NEW DESIGNED PAD FREE OF CHARGE. THE SAFETY RECALL BEGAN ON AUGUST 12, 2009. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

09V214000 · Steering:hydraulic Power Assist System

Jun 11, 2009

BLUE BIRD IS RECALLING 377 MODEL YEAR 2009 AND 2010 VISION CONVENTIONAL SCHOOL BUSES MANUFACTURED FROM MAY 13, 2008 THROUGH MAY 17, 2009, EQUIPPED WITH PROPANE ENGINES. THE POWER STEERING RETURN HOSE MAY LEAK AND/OR FAIL RESULTING IN LOSS OF HYDRAULIC STEERING ASSIST.

Consequence & remedy

Consequence: LOSS OF POWER STEERING ASSIST COULD RESULT IN A VEHICLE CRASH.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JULY 30, 2009. OWNERS MAY CONTACT BLUE BIRD AT 1-478-422-2242.

09V075000 · Engine And Engine Cooling:cooling System:fan

Mar 9, 2009

BLUE BIRD IS RECALLING 3,419 MY 2008 AND 2009 VISION CONVENTIONAL SCHOOL BUSES MANUFACTURED FROM JANUARY 18, 2007 THROUGH OCTOBER 29, 2008, EQUIPPED WITH CATERPILLAR C7 AND C7 07 ENGINES. INCORRECT BOLTS AND/OR SPACERS MAY HAVE BEEN INSTALLED TO ATTACH THE FAN BLADE TO THE FAN CLUTCH.

Consequence & remedy

Consequence: AS A RESULT, THE FAN BLADE MAY SEPARATE FROM THE CLUTCH AND POTENTIALLY CAUSE PROPERTY DAMAGE OR PERSONAL INJURY TO PERSONS IN OR NEAR THE FRONT OF THE BUS. THE VEHICLE SHOULD NOT BE SERVICED WITH THE HOOD OPEN AND THE ENGINE RUNNING UNTIL THE BOLTS/SPACERS HAVE BEEN INSPECTED AND, IF NEEDED, REPLACED.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND DEALERS WILL REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON APRIL 7, 2009. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

08V312000 · Service Brakes, Hydraulic

Jul 11, 2008

THE HYDRAULIC BRAKE HOSES FROM THE MASTER CYLINDER TO THE CHASSIS FRAME MAY HAVE BEEN IMPROPERLY ROUTED OR RETAINED ON CERTAIN 2004 THROUGH 2009 MY BLUE BIRD VISION CONVENTIONAL SCHOOL AND TRANSIT BUSES MANUFACTURED FROM JANUARY 11, 2004 THROUGH APRIL 22, 2008.

Consequence & remedy

Consequence: IMPROPER ROUTING OR RETENTION OF THE HYDRAULIC BRAKE HOSES MAY RESULT IN BRAKE HOSES CHAFFING AGAINST THE BUS BODY AND/OR CHASSIS COMPONENTS WHICH COULD CAUSE A LEAK IN THE HYDRAULIC BRAKE SYSTEM RESULTING IN REDUCED BRAKING CAPACITY WHICH COULD RESULT IN A CRASH.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND INSPECT AND REPAIR THE BUSES FREE OF CHARGE. THE RECALL BEGAN ON AUGUST 8, 2008. OWNERS MAY CONTACT BLUE BIRD AT 1-478-822-2242.

08V309000 · Engine And Engine Cooling:engine:diesel

Jul 10, 2008

A PLUG ON THE OUTLET SIDE OF THE FUEL PUMP CAN CRACK ON CERTAIN 2008 AND 2009 MY BLUE BIRD ALL AMERICAN AND VISION SCHOOL BUSES MANUFACTURED FROM MAY 23, 2007 THROUGH JULY 4, 2008, EQUIPPED WITH CATERPILLAR C7 ENGINES.

Consequence & remedy

Consequence: A CRACK IN THIS PLUG CAN RESULT IN A HIGH PRESSURE FUEL SPRAY OR LEAK WHICH, IN THE PRESENCE OF AN IGNITION SOURCE, COULD RESULT IN A FIRE.

Remedy: BLUE BIRD IS WORKING IN CONJUNCTION WITH CATERPILLAR TO NOTIFY OWNERS TO CONTACT THEIR LOCAL CATERPILLAR DEALER FOR A FREE REMEDY. THE RECALL IS EXPECTED TO BEGIN DURING JULY 2008. OWNERS CAN CONTACT CATERPILLAR AT 1-800-447-4986 OR BLUE BIRD AT 1-478-822-2242.

08V229000 · Structure:body:roof And Pillars

May 20, 2008

BLUE BIRD IS RECALLING 23,464 MY 2005 THROUGH 2009 ALL AMERICAN AND VISION SCHOOL AND TRANSIT MODEL BUSES MANUFACTURED FROM JANUARY 22, 2004, AND MARCH 28, 2008, AND MY 2004 THROUGH 2007 ALL AMERICAN SCHOOL BUSES AND CONVENTIONAL MODEL SCHOOL BUSES MANUFACTURED FROM MARCH 6, 2003, THROUGH JUNE 16, 2006. THE RIVET PATTERN MAY BE INCORRECT IN SECTIONS OF THE REAR ROOF SHEET JOINT THAT ATTACHES TO THE REAR ROOF CAP. WITHOUT THE APPROPRIATE AMOUNT OF ROOF RIVETS, THE BUSES FAIL TO CONFORM WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO 221, "JOINT STRENGTH."

Consequence & remedy

Consequence: IN THE EVENT OF A CRASH, THESE PANELS MAY SEPARATE EXPOSING THE OCCUPANTS TO INCREASED RISK OF INJURY.

Remedy: BLUE BIRD WILL NOTIFY OWNERS AND INSPECT AND REPAIR THE BUSES BY ADDING ADDITIONAL RIVETS. THE RECALL BEGAN ON SEPTEMBER 18, 2008. OWNERS MAY CONTACT BLUE BIRD AT 478-822-2242.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

4

PE10018 · Engine Compartment Fires

Opened May 27, 2010 · Closed Jul 9, 2010

Status: closed (inferred from source dates) · Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

Additional source detail variants (6)

Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

Fuel System, Other:fuel Injection System

This investigation was opened after ODI became aware of four engine compartment fires allegedly related to fuel leakage from the engine's fuel injector system.ODI conducted field examinations and communicated the identified concerns to Blue Bird.ODI also had discussions with Caterpillar, the engine manufacturer.On June 28th, 2010, Blue Bird filed two safety defect reports with NHTSA to address fuel lines that may crack at the fastening point to the common fuel rail. Safety recall campaign 10V-289 involves 3,686 school buses and safety recall campaign 10V-290 involves 103 non-school bus vehicles. The subject vehicles were equipped with the Caterpillar C-7-07 engine and it was determined that clamping of the #5 fuel line to the #6 fuel line and assembly stresses caused the #6 fuel line to fail. The remedy consist of replacing the #5 and #6 fuel lines and adding a new clamp to # 5 fuel line. Simultaneously with Blue Bird's decision to conduct the above recalls, Caterpillar Inc. filed a safety recall (10E-025) with NHTSA to perform the same remedy on 5,920 C7 series engines.Blue Bird engines are included in the Caterpillar recall.These recalls resolve the issues raised by this investigation. Therefore, this investigation is closed.

PE09029 · Sudden Loss Of Power Assist Steering

Opened Jun 5, 2009 · Closed Aug 28, 2009

Status: closed (inferred from source dates) · Steering:hydraulic Power Assist System

THIS INVESTIGATION WAS OPENED AFTER ODI RECEIVED SIX FLEET COMPLAINTS (19 BUSES TOTAL) ALLEGING REPEATED ISSUES OF THE POWER STEERING RESERVOIR GASKET FAILING.IT WAS ALLEGED THAT THE DEGRADED GASKET FELL INTO THE POWER STEERING PUMP, RESULTING IN AN INCREASEDSTEERING EFFORT.ODI IS AWARE OF TWO BUSES THAT, WITHOUT WARNING, LOST POWER ASSIST STEERING DURING NORMAL DRIVING OPERATIONS. REPORTEDLY, THE POWER STEERING GASKETS WERE MANUFACTURED WITH INCORRECT MATERIAL SUBSTITUTED BY ONE OF THE GASKET MATERIAL SUPPLIERS. AFTER ANEVALUATION INTO THIS ISSUE, BLUE BIRD AUTHORIZED A SAFETY RECALL. THE ORIGINAL POWER STEERING LID GASKET WILL BE REPLACED WITH NEW GASKET MATERIAL.THE ACTION TAKEN BY BLUE BIRD RESOLVES THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

PE09007 · Cooling Fan Separation

Opened Feb 12, 2009 · Closed Apr 9, 2009

Status: closed (inferred from source dates) · Engine And Engine Cooling:cooling System:fan

A BLUE BIRD CORPORATION SERVICE BULLETIN DATED DECEMBER 18, 2008, WARNS OWNERS THAT THE RADIATOR COOLING FAN ASSEMBLY MAY HAVE BEEN INSTALLED USINGINCORRECTLY SIZED BOLTS AND SPACERS ONMODEL YEARS 2008 AND 2009 VISION SCHOOL BUSES. THERE IS A POSSIBILITY THAT THE FAN BLADE MAY SEPARATE FROM THE CLUTCH MOUNTING POSITION. AFTER FURTHER REVIEW, ON MARCH 3, 2009, BLUE BIRD FILED A SAFETY RECALL TO INSPECT ALL INVOLVED BUSES. BLUE BIRD WILL REPLACED THE EXISTING SPACERS AND BOLTS IF FOUND TO BE THE INCORRECT HARDWARE.THIS RECALL ACTION RESOLVES THE ISSUES RAISED BY THIS INVESTIGATION. ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

PE08038 · Hydraulic Brake Hose Chafing/leaking

Opened Jun 4, 2008 · Closed Aug 4, 2008

Status: closed (inferred from source dates) · Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

IN APRIL, 2008, ODI RECEIVED A LETTER FROM THE MISSOURI STATE HIGHWAY PATROL ALLEGING THAT THEIR FIELD INSPECTORSWEREFINDING HYDRAULIC BRAKE HOSES THAT WEREBEING CUT OR CRUSHED BY THE SHARP EDGES OF THE BUS BODY AT THE FIREWALL.THEY ALSO SUPPLIED INFORMATION ON ONE BUS THAT EXPERIENCED TOTAL BRAKE LOSS DUE TO THE BRAKE HOSE BEING CUT. FURTHER FIELD WORK BY ODI INCREASED THENUMBER OF COMPLAINTS TO A TOTAL OF SEVEN.AFTER DISCUSSIONS WITH ODI AND FURTHER REVIEW OF FIELD INCIDENTS, BLUE BIRD HAS DECIDED TO INITIATE A SAFETY RECALL TO INSPECT, REPLACE AND OR REPOSITION THE BRAKE HOSES OF CONCERN. THIS RECALL ACTION RESOLVES THE ISSUES RAISED BY THIS INVESTIGATION. ACCORDINGLY, THIS INVESTIGATION IS CLOSED.