FIRE HAZARD ADD TO 10202950 WINNEBAGO JOURNEY D L,:, MODEL # 2002 WKP36GD, WITH UNDER 50,000 MILES. CLIMBING THE 21 MILE GRADE WAS NO PROBLEM FOR THIS 330 CAT DIESEL, AT LESS THAN 40 MILES PER HOUR I NOTICED THAT THE LEFT REAR BEDROOM SLIDE WAS OUT 4 INCHES. I FOUND A SAFE PLACE TO PULL OF THE ROAD. THE TURBO CHARGER HAD BEEN…
Read full complaint
FIRE HAZARD ADD TO 10202950 WINNEBAGO JOURNEY D L,:, MODEL # 2002 WKP36GD, WITH UNDER 50,000 MILES. CLIMBING THE 21 MILE GRADE WAS NO PROBLEM FOR THIS 330 CAT DIESEL, AT LESS THAN 40 MILES PER HOUR I NOTICED THAT THE LEFT REAR BEDROOM SLIDE WAS OUT 4 INCHES. I FOUND A SAFE PLACE TO PULL OF THE ROAD. THE TURBO CHARGER HAD BEEN WORKING PRETTY HARD COMING UP THE HILL SO AFTER SETTING THE PARK BRAKE I LET THE ENGINE IDLE WHILE I WENT TO THE REAR OF THE COACH TO RETRACT THE SLIDE, FORTUNATELY MY WIFE REMAINED IN FRONT. THE BEDROOM HAS NO WINDOW ON THE LEFT SO I SAW NOTHING UNUSUAL WHEN I PUSHED THE RETRACT SWITCH EXCEPT THE SLIDE DID NOT MOVE. MY WIFE INSTANTLY HOLLERED THAT SMOKE WAS COMING OUT FROM THE REAR LEFT SIDE. I RAN TO THE FRONT, TURNED OFF THE ENGINE, GRABBED THE FIRE EXTINGUISHER AND WE BOTH EXITED IN A HURRY. BY THE TIME I GOT TO THE REAR OF THE COACH GREY SMOKE WAS COMING OUT THE BACK PRETTY HEAVY. A TRUCK DRIVER HAD ALREADY STOPPED ACROSS THE ROAD FROM ME. HE RAN BACK TO HIS TRUCK AND CAME BACK WITH A LARGE, 30 OR 50 POUND EXTINGUISHER. MEANWHILE THINGS ARE HAPPENING FAST. A LOUD POP CAME FROM THE ENGINE COMPARTMENT FOLLOWED BY THE SOUND OF A LOT OF AIR BEING RELEASED. THE FIRE ACCELERATED QUICKLY AND TURNED BLACK WITH SOME YELLOWISH BROWN SWIRLS. ANOTHER LOUD POP CAME FROM THE ENGINE COMPARTMENT FOLLOWED BY A COUPLE OF QUARTS OF A BROWNISH CLEAR, OILY LIQUID DUMPED ON THE GROUND UNDER THE ENGINE COMPARTMENT. ANOTHER LOUD WOOSH WAS HERD, THE SMOKE GOT LIGHTER IN COLOR AND STARTED TO DECREES. THE LARGE EXTINGUISHER HAD DONE ITS JOB AND COMPLETELY EXTINGUISHED THE FIRE. THE TOTAL TIME INVOLVED FROM THE TIME I PUSHED THE RETRACT SWITCH TO THE FINAL BLAST OF THE FIRE EXTINGUISHER WAS NO MORE THAN 2 OR 3 MINUTES BUT SERIOUS DAMAGE HAD OCCURRED. *TR
WINNEBAGO IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.
Consequence & remedy
Consequence: THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.
Remedy: WINNEBAGO IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE RECALL BEGAN DURING DECEMBER 2010. OWNERS MAY CONTACT NORCOLD AT 1-800-767-9101 OR WINNEBAGO AT 1-641-585-3535.
WINNEBAGO IS RECALLING 1,547 MODEL YEAR 2001-2003 RECREATIONAL VEHICLES EQUIPPED WITH NORCOLD MODEL 1200LRIM REFRIGERATORS, MANUFACTURED FROM MARCH 1, 2001 TO DECEMBER 31, 2002, WITH SERIAL NUMBERS BETWEEN 1273701 AND 1536607, NON-CONSECUTIVELY. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE LIQUID SOLUTION TO SLOWLY LEAK. IF A LEAK OCCURS AND THE REFRIGERATOR CONTINUES TO BE OPERATED AFTER SOLUTION CIRCULATION HAS CEASED THE HEAT SOURCE COULD GENERATE VERY HIGH TEMPERATURES. AT SUCH HIGH TEMPERATURES, THE COOLING UNIT COULD RUPTURE.
Consequence & remedy
Consequence: IF A LEAK OCCURS AND THE UNIT IS CONTINUES TO OPERATE, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.
Remedy: WINNEBAGO IS WORKING WITH NORCOLD AND NORCOLD WILL NOTIFY OWNERS AND THE VEHICLE'S REFRIGERATOR WILL BE REPAIRED FREE OF CHARGE (PLEASE SEE 09E-027). OWNERS MAY CONTACT NORCOLD'S RECALL CENTER AT 1-800-767-9101.
VEHICLE DESCRIPTION: MOTOR HOMES (MODELS WKP36L, WKP36LD, AND IKP36LD). FOUR NUTS MAY HAVE LOOSENED FROM THE FOUR BOLTS THAT CONNECT THE LIQUID PROPANE (LP) TANK TO THE MOTOR HOME. IF THE ATTACHMENT HARDWARE IS LOOSENED, THE ROAD VIBRATION COULD PRODUCE UNDUE STRESS ON THE WELD JOINTS OF THE BRACKETS AND THEY COULD BREAK.
Consequence & remedy
Consequence: IF THIS HAPPENS, THE TANK COULD FALL OFF, RESULTING IN A ROAD HAZARD OR A FIRE.
Remedy: DEALERS WILL INSPECT THE LP TANK ATTACHMENT AND RE-TIGHTENED THE FASTENERS IN ADDITION TO ADDING LOCK NUTS. OWNER NOTIFICATION BEGAN AUGUST 24, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT WINNEBAGO AT 1-641-585-6939.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗