BATTERY CONTINUES TO GET DRAINED OF POWER FOR NO APPARENT REASON. I HAVE HAD TO GET A JUMP START SEVERAL TIMES EVEN AFTER DRIVING FOR 3 OR MORE HOURS. WHEN I TOOK IT TO THE DEALERSHIP, I WAS TOLD THAT THE BATTERY WAS FINE, BUT NEEDED TO BE CHARGED. THEY EXPLAINED THAT THE REASON FOR THE DEAD BATTERY WAS BECAUSE THE CAR WAS NOT …
Read full complaint
BATTERY CONTINUES TO GET DRAINED OF POWER FOR NO APPARENT REASON. I HAVE HAD TO GET A JUMP START SEVERAL TIMES EVEN AFTER DRIVING FOR 3 OR MORE HOURS. WHEN I TOOK IT TO THE DEALERSHIP, I WAS TOLD THAT THE BATTERY WAS FINE, BUT NEEDED TO BE CHARGED. THEY EXPLAINED THAT THE REASON FOR THE DEAD BATTERY WAS BECAUSE THE CAR WAS NOT STARTED FOR 2 OR MORE DAYS. LESS THAN A WEEK AFTER THIS VISIT TO THE DEALERSHIP, THE BATTERY WAS DEAD AGAIN AFTER A 4 HOUR DRIVE.
NHTSA ODI #11402729
30,000 miles · Mar 11, 2021
Electrical System
KEY INTERMITTENTLY CANNOT BE REMOVED FROM IGNITION. IT IS OCCURRING MORE FREQUENTLY.
NHTSA ODI #11400280
Mileage unknown · Mar 10, 2021
Electrical System
BATTERY DIES FREQUENTLY WITHOUT OBVIOUS CAUSE, EVEN AFTER REPLACING BATTERY SOONER THAN EXPECTED. IT HAPPENS AFTER DRIVING FOR 30 MINUTES, TURNING IT OFF FOR A SHORT PERIOD LIKE 15-20 MINUTES, THEN TRYING TO RESTART, AS WELL AS AFTER SITTING FOR 8-10 HOURS.
NHTSA ODI #11400199
45,600 miles · Mar 3, 2021
Electrical System
PARASITIC DRAIN OF BATTERY BY FAULTY ELECTRICAL SYSTEM OVERNIGHT.
NHTSA ODI #11398873
Mileage unknown · Mar 2, 2021
Electrical System
IN FOUR YEARS AND 18000 MILES, I AM NOW ON MY THIRD BATTERY AS OF TODAY. I HAVE READ OF RECURRENT ISSUES WITH 2016 OUTBACK BATTERY FAILURES. THE SECOND BATTERY I BOUGHT AT THE ORIGINAL DEALERSHIP WHEN THE VEHICLE HAD 13888 MILES. THE BATTERY WAS PURCHASED 5/15/19. TODAY, 3/2/21 I HAD TO PURCHASE A NEW BATTERY.
NHTSA ODI #11398792
Mileage unknown · Feb 28, 2021
Electrical System
BATTERY CONTINUES TO DIE EVEN AFTER BATTERY REPLACEMENT. THIS ISSUE STARTED TO HAPPEN 1 YEAR POST OWNERSHIP
NHTSA ODI #11398284
51,003 miles · Feb 26, 2021
Electrical System
I BELIEVE I AM EXPERIENCING BATTERY DRAIN DUE TO SOME FLAW IN THE ELECTRICAL SYSTEM. I'M ON MY 2ND. BATTERY AND JUST FOUND I COULDN'T START CAR AND NEEDED A JUMP.
NHTSA ODI #11398010
Mileage unknown · Feb 20, 2021
Electrical System
THE CAR BATTERY STARTED DYING FREQUENTLY. IT WAS REPLACED TWICE, FUNCTIONED FINE FOR A FEW MONTHS, AND THEN DIED AGAIN. IT WAS JUMPED ONE DAY, DIED AGAIN 4 DAYS LATER, JUMPED AGAIN AND WAS DEAD AGAIN 5 HOURS LATER.
NHTSA ODI #11397124
53,000 miles · Feb 17, 2021
Electrical System
OUR SUBARU OUTBACK ORIGINALLY DIED AFTER MY WIFE WAS SITTING IN THE CAR LISTENING TO THE RADIO FOR 10 MINUTES. THE DEALER STATED THAT LISTENING TO THE RADIO WAS THE CAUSE AND CHARGED UP THE BATTERY. COUPLE WEEKS LATER AND THE CAR DIES AGAIN THIS TIME JUST SITTING IN THE DRIVEWAY. WE INSTALLED A NEW BATTERY IN HOPES THE PROBLEM W…
Read full complaint
OUR SUBARU OUTBACK ORIGINALLY DIED AFTER MY WIFE WAS SITTING IN THE CAR LISTENING TO THE RADIO FOR 10 MINUTES. THE DEALER STATED THAT LISTENING TO THE RADIO WAS THE CAUSE AND CHARGED UP THE BATTERY. COUPLE WEEKS LATER AND THE CAR DIES AGAIN THIS TIME JUST SITTING IN THE DRIVEWAY. WE INSTALLED A NEW BATTERY IN HOPES THE PROBLEM WOULD BE FIXED. THE CAR HAS DIED MULTIPLE TIMES SINCE THE NEW BATTERY FROM SIMPLY SITTING IN THE DRIVEWAY. NO INTERIOR LIGHTS LEFT ON AND POWER LIGHT GATE CLOSED. AGAIN THE DEALER CHARGED THE BATTERY AND SENT US ON OUR WAY. WE CANNOT LEAVE THIS CAR SITTING ONE DAY WITHOUT THE BATTERY DRAINING. WE ARE NOW ON BATTERY NUMBER TWO.
NHTSA ODI #11396713
Mileage unknown · Feb 17, 2021
Electrical System
BATTERY DRAINS CONSTANTLY. CAR CANNOT SIT FOR MORE THAN A FEW DAYS WITHOUT BATTERY BEING DEAD. SUBARU DEALER SAYS THERE IS NO PROBLEM. CAR NEEDS TO BE DRIVEN 20 TO 30 MILES EVERY DAY AS A SOLUTION? PROBLEM HAS BEEN HAPPENING FOR MONTHS AND BATTERY IS ONLY 1 YEAR OLD.
Subaru of America, Inc. (Subaru) is recalling certain 2016-2017 Outback vehicles. A replacement air bag control module may have been installed that is not compatible with the passenger air bag module, possibly affecting air bag deployment.
Consequence & remedy
Consequence: In the event of a crash necessitating passenger frontal air bag deployment, the air bag may not deploy properly, increasing the risk of injury.
Remedy: Subaru will notify owners, and dealers will replace the passenger air bag module, free of charge. The recall began February 3, 2020. Owners may contact Subaru customer service at 1-844-373-6614. Subaru's number for this recall is WUX-09.
Subaru of America, Inc. (Subaru) is recalling certain model year 2016-2017 Legacy and Outback vehicles manufactured February 29, 2016, to May 6, 2016. The steering column on the affected vehicles may have been improperly machined, and as a result, turning the steering wheel may have no effect on the direction of the wheels.
Consequence & remedy
Consequence: The loss of steering ability would increase the risk of a crash.
Remedy: Subaru will notify owners, and dealers will inspect the lot number on the steering column, replacing the steering column, as necessary, free of charge. The recall began May 13, 2016. Owners may contact Subaru customer service at 1-800-782-2783 or by visiting http://www.wtd65.service-campaign.com. Subaru's number for this recall is WTD-65. Note: Until the vehicles have been inspected, owners are advised not to drive their vehicles.
Subaru of America, Inc. (Subaru) is recalling certain model year 2016 Legacy vehicles manufactured October 24, 2015, to November 16, 2015, and Outback vehicles manufactured October 24, 2015, to November 17, 2015. Due to the improper tightening of the securing nuts, the drive shaft may separate from the rear differential.
Consequence & remedy
Consequence: If the drive shaft detaches from the rear differential, it may strike the fuel tank and result in a fuel leak, increasing the risk of a fire.
Remedy: Subaru has notified owners, and dealers will inspect the fastening nuts, and tighten or replace them, as necessary, free of charge. The recall began on December 10, 2015. Owners may contact Subaru customer service at 1-856-488-8500. Subaru's number for this recall is WQV-57.
Additional source detail variants (2)
Power Train:driveline:differential Unit
Subaru of America, Inc. (Subaru) is recalling certain model year 2016 Legacy vehicles manufactured October 24, 2015, to November 16, 2015, and Outback vehicles manufactured October 24, 2015, to November 17, 2015. Due to the improper tightening of the securing nuts, the drive shaft may separate from the rear differential.
Consequence: If the drive shaft detaches from the rear differential, it may strike the fuel tank and result in a fuel leak, increasing the risk of a fire.
Remedy: Subaru has notified owners, and dealers will inspect the fastening nuts, and tighten or replace them, as necessary, free of charge. The recall began on December 10, 2015. Owners may contact Subaru customer service at 1-856-488-8500. Subaru's number for this recall is WQV-57.
Power Train:driveline:driveshaft
Subaru of America, Inc. (Subaru) is recalling certain model year 2016 Legacy vehicles manufactured October 24, 2015, to November 16, 2015, and Outback vehicles manufactured October 24, 2015, to November 17, 2015. Due to the improper tightening of the securing nuts, the drive shaft may separate from the rear differential.
Consequence: If the drive shaft detaches from the rear differential, it may strike the fuel tank and result in a fuel leak, increasing the risk of a fire.
Remedy: Subaru has notified owners, and dealers will inspect the fastening nuts, and tighten or replace them, as necessary, free of charge. The recall began on December 10, 2015. Owners may contact Subaru customer service at 1-856-488-8500. Subaru's number for this recall is WQV-57.
Subaru of America, Inc. (Subaru) is recalling certain 2015 and 2016 model year Subaru Legacy 4-Door and Outback vehicles manufactured July 3, 2015, to July 27, 2015. Transmission oil may leak from a deformed seal cap on the propeller shaft yoke.
Consequence & remedy
Consequence: If the transmission oil leaks onto the exhaust pipe, there is a possible risk of fire.
Remedy: Subaru will notify owners, and dealers will replace the propeller shaft, free of charge. The recall began on August 28, 2015. Owners may contact 1-800-782-2783. Subaru's number for this recall is WQU-56.
Additional source detail variants (2)
Power Train:automatic Transmission
Subaru of America, Inc. (Subaru) is recalling certain 2015 and 2016 model year Subaru Legacy 4-Door and Outback vehicles manufactured July 3, 2015, to July 27, 2015. Transmission oil may leak from a deformed seal cap on the propeller shaft yoke.
Consequence: If the transmission oil leaks onto the exhaust pipe, there is a possible risk of fire.
Remedy: Subaru will notify owners, and dealers will replace the propeller shaft, free of charge. The recall began on August 28, 2015. Owners may contact 1-800-782-2783. Subaru's number for this recall is WQU-56.
Power Train:driveline:driveshaft
Subaru of America, Inc. (Subaru) is recalling certain 2015 and 2016 model year Subaru Legacy 4-Door and Outback vehicles manufactured July 3, 2015, to July 27, 2015. Transmission oil may leak from a deformed seal cap on the propeller shaft yoke.
Consequence: If the transmission oil leaks onto the exhaust pipe, there is a possible risk of fire.
Remedy: Subaru will notify owners, and dealers will replace the propeller shaft, free of charge. The recall began on August 28, 2015. Owners may contact 1-800-782-2783. Subaru's number for this recall is WQU-56.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
EA21002 · Desiccated Air Bag Inflator Rupture
Opened Sep 17, 2021 · No close date supplied
Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Additional source detail variants (2)
Air Bags:frontal:driver Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.