OFFICIAL NHTSA RECALL
95E025001
Fuel System, Other:storage:tank Assembly:pressure Relief Devices
Reported Aug 28, 1995 · EDO CANADA, LTD.
Summary
SOME TEMPERATURE SENSITIVE TRIGGERS WERE NOT X-RAYED. THESE TRIGGERS COULD CONTAIN INTERNAL VOIDS THAT WOULD MAKE THE TRIGGERS SUSCEPTIBLE TO ADVANCED CREEP CAUSING FALSE ACTIVATION AND VENTING OF THE CNG.
Consequence
VENTING OF THE CNG COULD RESULT IN A FIRE.
Remedy
EDO CANADA HAS GONE OUT OF BUSINESS. THE CORRECTION WAS TO CONDUCT AN INSPECTION/EXCHANGE PROGRAM FOR ALL NON X-RAYED AND "BULGED" TRIGGERS ON THE MIRADA PRESSURE RELIEF DEVICES.
Notes
SYSTEM: FUEL; CNG; PRESSURE RELIEF VALVES/DEVICES.EQUIPMENT DESCRIPTION: "LITERIDER" CNG CYLINDERS WHICH INCORPORATE MIRADATYPE III PRESSURE RELIEF DEVICES (PART NOS. B-51440, B-51363, AND B-51246-3).(SEE MIRADA CAMPAIGN NO. 95E025).NOTE: IF THE VALVES HAVE NOT BEEN REPLACED WITHIN A REASONABLE TIME FREE OFCHARGE, PLEASE CONTACT EDO CANADA AT 1-608-868-4626. ALSO CONTACT THE NATIONALHIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.