NHTSA owner reports · September 18, 2026 snapshot.
Visibility complaints
73 reportsClear category filter65,000 miles · Jun 27, 2018
Visibility
TL* THE CONTACT OWNS A 2006 PONTIAC TORRENT. WHILE OPERATING THE VEHICLE, THE HEATER FAILED TO PRODUCE HOT AIR AND THE WINDOWS FAILED TO DEFROST. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHO DIAGNOSED THAT THE HEATER BLEND DOOR WAS FAULTY AND NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER AND LOCAL…
Read full complaint
TL* THE CONTACT OWNS A 2006 PONTIAC TORRENT. WHILE OPERATING THE VEHICLE, THE HEATER FAILED TO PRODUCE HOT AIR AND THE WINDOWS FAILED TO DEFROST. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHO DIAGNOSED THAT THE HEATER BLEND DOOR WAS FAULTY AND NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER AND LOCAL DEALER (LANCE BUICK GMC, 2 CHAUNCY ST, MANSFIELD, MA) WERE BOTH NOTIFIED OF THE FAILURE, BUT NO ASSISTANCE WAS OFFERED. THE FAILURE MILEAGE WAS 65,000. THE VIN WAS NOT AVAILALBLE.
NHTSA ODI #11104279
175,000 miles · Feb 28, 2017
Visibility
TL* THE CONTACT OWNS A 2006 PONTIAC TORRENT. THE CONTACT STATED THAT THE DEFROST SYSTEM FAILED TO OPERATE WHEN ACTIVATED IN COLD TEMPERATURES. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHERE IT WAS DIAGNOSED THAT THE BLEND DOOR ACTUATOR FAILED AND NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS N…
Read full complaint
TL* THE CONTACT OWNS A 2006 PONTIAC TORRENT. THE CONTACT STATED THAT THE DEFROST SYSTEM FAILED TO OPERATE WHEN ACTIVATED IN COLD TEMPERATURES. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHERE IT WAS DIAGNOSED THAT THE BLEND DOOR ACTUATOR FAILED AND NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS 175,000.
NHTSA ODI #10957572
120,000 miles · Dec 10, 2014
Visibility
THE HEATER IS NOT BLOWING ANY HOT AIR AT ALL. THE KNOBS/SWITCHES ALL WORK AND IT FORCES AIR OUT BUT ITS VERY COLD AIR, AFTER READING THIS SITE AND OTHERS IT LOOKS LIKE THE BLEND DOOR IS BROKEN, THERE NEEDS TO BE A RECALL ON THIS. I SEEN THE SERVICE ALERT FOR IT BUT IT SAYS UP TO 100,000 MILES, MINE HAD MORE THAN THAT WHEN I PURC…
Read full complaint
THE HEATER IS NOT BLOWING ANY HOT AIR AT ALL. THE KNOBS/SWITCHES ALL WORK AND IT FORCES AIR OUT BUT ITS VERY COLD AIR, AFTER READING THIS SITE AND OTHERS IT LOOKS LIKE THE BLEND DOOR IS BROKEN, THERE NEEDS TO BE A RECALL ON THIS. I SEEN THE SERVICE ALERT FOR IT BUT IT SAYS UP TO 100,000 MILES, MINE HAD MORE THAN THAT WHEN I PURCHASED IT, GM SHOULD AT LEAST PAY FOR IT NO MATTER HOW MANY MILES. I HAVE A TODDLER AND ITS WAY TO COLD TO BE RIDING IN THE CAR WITH NO HEAT. THIS NEEDS TO BE FIXED NOW! *TR
NHTSA ODI #10663301
140,000 miles · Mar 5, 2014
Visibility
TL* THE CONTACT OWNS A 2006 PONTIAC TORRENT. THE CONTACT STATED THAT THE HEATER UNIT MALFUNCTIONED. THE VEHICLE WAS NOT TAKEN TO THE DEALER. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 140,000.
NHTSA ODI #10567396
158,000 miles · Feb 28, 2014
Visibility
DRIVING, TURNED THE DEFROST ON, ONLY COLD AIR CAME OUT, UNABLE TO DEFOG OR DEFROST WINDSHIELD. NO HEAT WHATSOEVER. BLOWS COLD AIR AT ALL TIMES. APPARENTLY SOME OF THE OTHER GM VEHICLES BASED ON THE SAME PLATFORM HAVE HAD THE SAME PROBLEMS. *TR
NHTSA ODI #10566492
80,000 miles · Nov 13, 2013
Electrical SystemElectronic Stability Control (esc)Visibility
I AM TOTALLY OUTRAGED FINDING OUT THAT GM PLACED A NON SAFE PART ON THIS TRUCK THAT I BOUGHT BRAND NEW. IT WILL COST $1000.00 EVEN AFTER KEEPING THIS TRUCK MAINTENANCE FREE, TROUBLE FREE FROM REGULAR MAINTENANCE AT THE DELIVER THAT I PURCHASED IT FROM. I AM VERY UPSET THAT THIS PART WAS NOT RECALLED AS THE PART COSTS BETWEEN $22…
Read full complaint
I AM TOTALLY OUTRAGED FINDING OUT THAT GM PLACED A NON SAFE PART ON THIS TRUCK THAT I BOUGHT BRAND NEW. IT WILL COST $1000.00 EVEN AFTER KEEPING THIS TRUCK MAINTENANCE FREE, TROUBLE FREE FROM REGULAR MAINTENANCE AT THE DELIVER THAT I PURCHASED IT FROM. I AM VERY UPSET THAT THIS PART WAS NOT RECALLED AS THE PART COSTS BETWEEN $22-100.00 WHILE THE LABOR BECAUSE OF WHERE IT IS WILL COST UP TO $1000.00 AT THE DEALER I PURCHASED IT FROM AND GET REGULAR MAINTENANCE CHECK UPS WITH. I TOTALLY AGREE WITH ALL OF THE CONSUMERS ON HERE: THE ACTUATOR THAT OPERATES THE HEATER BLEND DOOR - OVEREXTENDS AND BREAKS THE HEATER BLEND DOOR. THIS CAUSES THE HEATER TO NOT WORK AT ALL. THE ACTUATORS ARE DEFECTIVE AND THE HEATER DOORS ARE DEFECTIVE BECAUSE THEY BREAK DUE TO A MANUFACTURERS DEFECT. IF THE HEAT DOESN'T WORK THE WINDOWS WON'T DEFROST SO THIS IS A VISIBILITY HAZARD. I ALSO LISTED IT AS AN ELECTRICAL AND UNKNOWN HAZARD. *TR
NHTSA ODI #10552085
43,000 miles · Aug 15, 2012
Engine And Engine CoolingVisibility
THIS IS AN ISSUE WITH THE ACTUATOR THAT MOVES THE FLAP IN THE HEATER/AC CASE. THIS CAUSES THE HEAT NOT TO BE RELEASED INTO THE CAR, JUST COLD AIR. THIS ISSUE IS ALL OVER THE INTERNET WITH SEVERAL PEOPLE HAVING THE SAME ISSUE. I BELIEVE THAT GM NEEDS TO SEE THIS ISSUE AS A FAULT OF THE PART. THE REPAIR FOR THIS UNIT REQUIRES COMP…
Read full complaint
THIS IS AN ISSUE WITH THE ACTUATOR THAT MOVES THE FLAP IN THE HEATER/AC CASE. THIS CAUSES THE HEAT NOT TO BE RELEASED INTO THE CAR, JUST COLD AIR. THIS ISSUE IS ALL OVER THE INTERNET WITH SEVERAL PEOPLE HAVING THE SAME ISSUE. I BELIEVE THAT GM NEEDS TO SEE THIS ISSUE AS A FAULT OF THE PART. THE REPAIR FOR THIS UNIT REQUIRES COMPLETE REMOVAL OF THE DASH BOARD. I HAVE GOTTEN QUOTES FROM 900-1500 TO REPAIR THIS PART AND THEY DO NOT SAY THAT ITS NOT GOING TO HAPPEN AGAIN. *TR
NHTSA ODI #10470718
56,000 miles · Apr 26, 2012
Electrical SystemVisibility
THE ACTUATOR THAT OPERATES THE HEATER BLEND DOOR - OVEREXTENDS AND BREAKS THE HEATER BLEND DOOR. THIS CAUSES THE HEATER TO NOT WORK AT ALL. THE ACTUATORS ARE DEFECTIVE AND THE HEATER DOORS ARE DEFECTIVE BECAUSE THEY BREAK DUE TO A MANUFACTURERS DEFECT. IF THE HEAT DOESN'T WORK THE WINDOWS WON'T DEFROST SO THIS IS A VISIBILITY HA…
Read full complaint
THE ACTUATOR THAT OPERATES THE HEATER BLEND DOOR - OVEREXTENDS AND BREAKS THE HEATER BLEND DOOR. THIS CAUSES THE HEATER TO NOT WORK AT ALL. THE ACTUATORS ARE DEFECTIVE AND THE HEATER DOORS ARE DEFECTIVE BECAUSE THEY BREAK DUE TO A MANUFACTURERS DEFECT. IF THE HEAT DOESN'T WORK THE WINDOWS WON'T DEFROST SO THIS IS A VISIBILITY HAZARD. I ALSO LISTED IT AS AN ELECTRICAL AND UNKNOWN HAZARD. THERE ARE THOUSANDS OF COMPLAINTS OUT ON THE INTERNET FOR THE 2006 PONTIAC TORRENTS & CHEVY EQUINOX'S AND ALL OF THEM HAVE THE SAME PROBLEM AND MOST OF THEM ARE AROUND THE 50,000 MILE MARK. GM WILL NOT PAY FOR IT IF IT IS PAST THE WARRANTY BECAUSE THEY SAY THERE ISN'T A RECALL FOR THIS. THESE 2 PARTS SHOULD BE RECALLED BECAUSE IT IS A HAZARD TO DRIVE YOUR VEHICLE IF YOU CAN'T DEFROST YOUR WINDOWS. IT IS APPROXIMATELY $900-$1200 TO FIX BECAUSE THEY NEED TO TAKE APART THE ENTIRE DASH BOARD TO GET AT THE ACTUATOR AND THE BLEND DOOR. GM SHOULD STAND BEHIND THIS AND FIX THIS SO THAT PEOPLE CAN DRIVE SAFELY AND BE ABLE TO SEE OUT THEIR WINDOWS. *TR
NHTSA ODI #10456546
68,000 miles · Feb 3, 2012
Visibility
I OWN A 2006 PONTIAC TORRENT DRIVING ALONG ONE DAY AND THE HEAT JUST WENT OUT. THIS CAUSED A DANGEROUS SITUATION AS THE DEFROST STOPPED WORKING AS WELL. I HAVE BEEN UNABLE TO DRIVE THE CAR IN THE WINTER FOR GOING ON THREE YEARS NOW ITS JUST NOT SAFE. DUE TO THE NUMBER OF COMPLAINTS FILED FOR THIS SAME EXACT THING IT IS UNBELIEVA…
Read full complaint
I OWN A 2006 PONTIAC TORRENT DRIVING ALONG ONE DAY AND THE HEAT JUST WENT OUT. THIS CAUSED A DANGEROUS SITUATION AS THE DEFROST STOPPED WORKING AS WELL. I HAVE BEEN UNABLE TO DRIVE THE CAR IN THE WINTER FOR GOING ON THREE YEARS NOW ITS JUST NOT SAFE. DUE TO THE NUMBER OF COMPLAINTS FILED FOR THIS SAME EXACT THING IT IS UNBELIEVABLE TO ME THAT THE GOVERNMENT DOES NOT FORCE GM TO CONDUCT A RECALL BEFORE SOMEONE GETS KILLED. *KB
NHTSA ODI #10446599
Mileage unknown · Jan 12, 2012
Visibility
THE BLEND DOOR FOR HEATER IS BROKEN AND ONLY COLD AIR IS ALLOWED TO FLOW THROUGH. THIS HAS BEEN DOCUMENTED TO BREAK IN MANY TORRENTS. THE DOOR IS DESIGNED TO ONLY MOVE 60 DEGREES BUT THE ACTUATOR IS DESIGNED TO MOVE 180 DEGREES CAUSING THE DOOR TO BREAK. WHEN I CALLED TO TALK TO SEVERAL BODY SHOPS TO DISCUSS THIS ISSUE, THEY EXP…
Read full complaint
THE BLEND DOOR FOR HEATER IS BROKEN AND ONLY COLD AIR IS ALLOWED TO FLOW THROUGH. THIS HAS BEEN DOCUMENTED TO BREAK IN MANY TORRENTS. THE DOOR IS DESIGNED TO ONLY MOVE 60 DEGREES BUT THE ACTUATOR IS DESIGNED TO MOVE 180 DEGREES CAUSING THE DOOR TO BREAK. WHEN I CALLED TO TALK TO SEVERAL BODY SHOPS TO DISCUSS THIS ISSUE, THEY EXPLAINED TO ME THAT THIS HAPPENS IN MANY TORRENTS AND GM WILL NOT RECALL THE PART AND IT IS MY RESPONSIBILITY TO GET IT FIXED WHICH COULD COST ME BETWEEN $1000 AND $1500 FOR LABOR AND PARTS. *TR
NHTSA ODI #10443595