Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2006 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

376 reports with mileage · 54 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 194 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 46 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 45 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

14 crash reports10 fire reports7 injury reports

What owners actually said

430 reports
Mileage unknown · Jul 30, 2018
Air BagsElectrical SystemFuel/propulsion System

IT WILL CRANK BUT WILL NOT START

NHTSA ODI #11114565

Mileage unknown · Jun 18, 2018
Fuel/propulsion System

TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT STATED THAT THE INSTRUMENT PANEL FUEL GAUGE INACCURATELY DISPLAYED THAT THE VEHICLE HAD A QUARTER TANK OF FUEL WHEN THE FUEL TANK WAS ACTUALLY EMPTY. THE FAILURE OCCURRED SEVERAL TIMES. THE VEHICLE WAS INCLUDED IN NHTSA CAMPAIGN NUMBER: 10V074000 (FUEL SYSTEM, OTHER); HOWEVER…

Read full complaint

TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT STATED THAT THE INSTRUMENT PANEL FUEL GAUGE INACCURATELY DISPLAYED THAT THE VEHICLE HAD A QUARTER TANK OF FUEL WHEN THE FUEL TANK WAS ACTUALLY EMPTY. THE FAILURE OCCURRED SEVERAL TIMES. THE VEHICLE WAS INCLUDED IN NHTSA CAMPAIGN NUMBER: 10V074000 (FUEL SYSTEM, OTHER); HOWEVER, THE CONTACT DID NOT RECEIVE A RECALL NOTIFICATION. THE DEALER WAS NOT CONTACTED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURES. THE FAILURE MILEAGE WAS NOT AVAILABLE.

NHTSA ODI #11102404

74,000 miles · Feb 26, 2018
Air BagsElectrical SystemCrash

MY VEHICLE IMPACTED ANOTHER VEHICLE FROM THE REAR AND AIR BAGS DID NOT DEPLOY. THE AIR BAG LIGHT HAS BEEN ON. SEVERAL ELECTRICAL PROBLEMS; STEERING WHEEL BUTTONS STOPPED WORKING IN 2008, ABS LIGHT REMAINS ON, BACKUP SENSOR WENT OUT 11-17 AND MOST RECENTLY I STARTED MY VEHICLE ONE MORNING AND SPEAKERS STARTED POPPING REALLY LOUD …

Read full complaint

MY VEHICLE IMPACTED ANOTHER VEHICLE FROM THE REAR AND AIR BAGS DID NOT DEPLOY. THE AIR BAG LIGHT HAS BEEN ON. SEVERAL ELECTRICAL PROBLEMS; STEERING WHEEL BUTTONS STOPPED WORKING IN 2008, ABS LIGHT REMAINS ON, BACKUP SENSOR WENT OUT 11-17 AND MOST RECENTLY I STARTED MY VEHICLE ONE MORNING AND SPEAKERS STARTED POPPING REALLY LOUD AND IMMEDIATELY SMELLED OF BURNED WIRES AND JUST TWO DAYS LATER VEHICLE WOULD NOT START, BATTERY WAS COMPLETELY DRAINED. AFTER CHARGING WORKED FINE FOR A COUPLE OF DAYS BUT JUST REPEATED THE SAME SITUATION. THIS VEHICLE HAS GAVE ME SO MANY ELECTRICAL PROBLEMS STARTING A YEAR AFTER PURCHASE. ALSO NOTICED THAT ONE OF THE A FRAMES WELDED JOINTS IS CRACKED. I AM A CERTIFIED WELDING INSPECTOR AND CAN SAY THAT IT IS A MANUFACTURER DISCONTINUITY. THE CATALYTIC CONVERTERS WENT OUT YEARS AFTER PURCHASE IN 2006. I HAVE HAD TO REPLACE THE ENGINE BECAUSE OF THE CATALYTIC CONVERTERS. I AM THE ONE AND ONLY OWNER AND PURCHASED IT NEW WITH ONLY 17 MILES ON IT. THIS VEHICLE HAS HAD SO MANY ELECTRICAL/MECHANICAL ISSUES THAT IM STARTING TO THINK I SHOULD APPLY UNDER LEMON LAW BUT I DONT KNOW HOW TO DO THAT.

NHTSA ODI #11075121

78,500 miles · Jan 31, 2018
Service Brakes

TL* THE CONTACT OWNS A 2006 NISSAN TITAN. WHILE DRIVING VARIOUS SPEEDS, THE ABS SEIZED WITHOUT WARNING AND THERE WAS AN ABNORMAL NOISE OCCASIONALLY COMING FROM BOTH FRONT WHEELS. ON SEVERAL OCCASIONS, THE BRAKES INDEPENDENTLY ACTIVATED WHILE THE VEHICLE WAS BEING DRIVEN. THE CONTACT STATED THAT THE FAILURE RECURRED SEVERAL TIMES…

Read full complaint

TL* THE CONTACT OWNS A 2006 NISSAN TITAN. WHILE DRIVING VARIOUS SPEEDS, THE ABS SEIZED WITHOUT WARNING AND THERE WAS AN ABNORMAL NOISE OCCASIONALLY COMING FROM BOTH FRONT WHEELS. ON SEVERAL OCCASIONS, THE BRAKES INDEPENDENTLY ACTIVATED WHILE THE VEHICLE WAS BEING DRIVEN. THE CONTACT STATED THAT THE FAILURE RECURRED SEVERAL TIMES. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC TO BE DIAGNOSED, BUT THEY WERE UNABLE TO PRODUCE A FAULT CODE OR DUPLICATE THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 78,500.

NHTSA ODI #11066079

Mileage unknown · Dec 23, 2017
EngineFuel/propulsion System

I FOUND MY TRUCK HAS 3 RECALLS THAT NEED TO BE DONE. BUT MY EXHAUST MANIFOLD IS ALSO CRACKED I HAVE HEARD OF THIS BING A KNOWN PROBLEM AS WELL. IT HAS BEEN CRACKED AND LEAKING FOR A WHILE BUT I HAVEN'T BEEN DRIVING IT TO MUCH SEENS IT'S BEEN LEAKING.

NHTSA ODI #11056200

48,000 miles · Dec 22, 2017
Air BagsCrash

TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT STATED THAT THE VEHICLE WAS INVOLVED IN A FRONT END COLLISION. THE AIR BAGS DID NOT DEPLOY, AND THE AIR BAG WARNING INDICATOR ILLUMINATED INTERMITTENTLY. A POLICE REPORT WAS FILED. THE VEHICLE WAS TOWED TO AN INDEPENDENT MECHANIC WHERE THE TECHNICIAN RECOMMENDED TO TOW THE VE…

Read full complaint

TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT STATED THAT THE VEHICLE WAS INVOLVED IN A FRONT END COLLISION. THE AIR BAGS DID NOT DEPLOY, AND THE AIR BAG WARNING INDICATOR ILLUMINATED INTERMITTENTLY. A POLICE REPORT WAS FILED. THE VEHICLE WAS TOWED TO AN INDEPENDENT MECHANIC WHERE THE TECHNICIAN RECOMMENDED TO TOW THE VEHICLE TO NISSAN. THE VEHICLE WAS DEEMED OPERABLE. THE VEHICLE WAS ALSO TAKEN TO CARRIAGE NISSAN (2400 BROWNS BRIDGE RD, GAINESVILLE, GA), BUT WAS NOT DIAGNOSED. THERE WERE NO INJURIES. THE FAILURE MILEAGE WAS 48,000.

NHTSA ODI #11056030

284,000 miles · Nov 30, 2017
Air Bags

HAD A RECALL ON THE 2004-2006 AIR BAGS AND TOOK TITAN IN TO UNIVERSITY NISSAN IN FLORENCE, AL. WAS INFORMED THAT THE RECALL COULD NOT BE COMPLETED ON SOME OF THE 2004-2006 TITANS AND THEY WOULD CONTACT NISSAN TO GET A SOLUTION. AFTER SEVERAL MONTHS OF WAITING I CONTACTED NISSAN USA AND THEN UNIVERSITY NISSAN TRIED AGAIN TO REPRO…

Read full complaint

HAD A RECALL ON THE 2004-2006 AIR BAGS AND TOOK TITAN IN TO UNIVERSITY NISSAN IN FLORENCE, AL. WAS INFORMED THAT THE RECALL COULD NOT BE COMPLETED ON SOME OF THE 2004-2006 TITANS AND THEY WOULD CONTACT NISSAN TO GET A SOLUTION. AFTER SEVERAL MONTHS OF WAITING I CONTACTED NISSAN USA AND THEN UNIVERSITY NISSAN TRIED AGAIN TO REPROGRAM THE AIRBAGS BUT IT STILL WOULD NOT TAKE. NOW I HAVE FOUND OUT THAT NISSAN HAS SUSPENDED THE RECALL UNTIL SUCH TIME THAT THEY CAN PRODUCE A PROGRAM TO FIX THIS RECALL. I KNOW, OTHER OWNERS ARE HAVING SAME PROBLEM AND NOW WHAT CAN BE DONE ? IF AIR BAGS DECIDE TO GO OFF ON MY VEHICLE, WHO IS RESPONSIBLE FOR SAFETY OF MY FAMILY AND THE REPAIRS TO FIX IF THE AIR BAGS DEPLOY FOR NO REASON ? I NEED MY VEHICLE AND CANNOT PARK UNTIL THEY DECIDE TO FIX THEIR MISTAKE. I NEED SOME HELP IN GETTING THIS RECALL TAKEN CARE OF. IF YOU CANNOT HELP THEN WHERE DO I TURN FOR HELP. EMMETT JONES

NHTSA ODI #11051501

20,599 miles · Nov 28, 2017
Steering

POWER STEERING FAILURE WHILE TURNING WITH ONLY 20599 MILES ON VEHICLE. LOCAL NISSAN DEALERSHIP REFILLED FLUID. FAILED AGAIN ONLY MONTHS LATER. A WEB SEARCH INDICATED THAT POWER STEERING HOSE FAILURE IS COMMON ON THIS VEHICLE.

NHTSA ODI #11048887

Mileage unknown · Nov 10, 2017
Electrical SystemSeat Belts

KEEP GETTING A RECALL NOTIFICATION FOR OUR TRUCK. HOWEVER CHECK THE VIN # OUT AND IT SAYS NOTHING IS THERE. BUT IN THE MAIL TODAY IT SAYS THERE IS STILL A RECALL FOR THE WIRE HARNESS ROUTED THROUGH THE REAR DOORS ON THE CAMPAIGN # 06V-459

NHTSA ODI #11045170

Mileage unknown · Nov 7, 2017
Engine

EXHAUST MANIFOLDS LEFT AND RIGHT CRACKED AND LEAKING LESS THAN 1 MOS OUT OF WARRENTY NISSAN REFUSED ANY ASSISTANCE. I WAS A NISSAN PARTS MGR FOR 50 YRS NO CONSIDERATION. WHEN MY WIFE NEEDED A NEW CAR FOR HER 2001 SENTRA WE PURCHASED A MAZDA CX5 INSTEAD OF A ROUGE

NHTSA ODI #11044258

Official recalls

5

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V064000 · Latches/locks/linkages:doors:latch

Mar 8, 2006

CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.

Consequence & remedy

Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.

Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.