Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
580–25K
7925–50K
10050–75K
6475–100K
51100–150K
24150K+
376 reports with mileage · 54 unknown
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
Power Train. Review the 194 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Electrical System. Review the 46 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Suspension. Review the 45 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
14 crash reports10 fire reports7 injury reports
What owners actually said
430 reports
33,311 miles · Oct 26, 2007
Power Train
MY VEHICLE IS A 2006 NISSAN TITAN SE CREW CAB 4X4. I WAS LOOKING AT MY NEW TIRES WHEN I NOTICED FLUID LEAKING AT THE END OF THE AXLE WHERE IT JOINS WITH THE WHEEL. FORTUNATELY, THERE WAS NO FAILURE. I TOOK IT 2 MILES DOWN THE ROAD TO CENTRAL VALLEY NISSAN UPON NOTICING THIS PROBLEM (I WAS DOWN THERE WITHIN 30 MINUTES). THE S…
Read full complaint
MY VEHICLE IS A 2006 NISSAN TITAN SE CREW CAB 4X4. I WAS LOOKING AT MY NEW TIRES WHEN I NOTICED FLUID LEAKING AT THE END OF THE AXLE WHERE IT JOINS WITH THE WHEEL. FORTUNATELY, THERE WAS NO FAILURE. I TOOK IT 2 MILES DOWN THE ROAD TO CENTRAL VALLEY NISSAN UPON NOTICING THIS PROBLEM (I WAS DOWN THERE WITHIN 30 MINUTES). THE SERVICE MANAGER SAID THEY HAVE SEEN THIS ON TITANS BEFORE. HE SAID IT IS A REAR AXLE SEAL THAT HAS FAILED. I WAS TOLD THIS HAPPENS BECAUSE THE AXLE WARPS. I MADE AN APPOINTMENT TO HAVE THIS FIXED THE NEXT DAY (I AM GOING DOWN FIRST THING TOMORROW MORNING). I AM HOPEFUL THAT THIS PROBLEM WILL NOT OCCUR AGAIN WITH MY VEHICLE. BASED ON INTERNET SEARCHES, THIS PROBLEM SEEMS TO BE FAIRLY WIDESPREAD. SINCERELY, MICHAEL JAMES *TR
NHTSA ODI #10207045
33,000 miles · Oct 19, 2007
Power Train
RIGHT REAR SEAL LEAKING. *TR
NHTSA ODI #10206370
25,000 miles · Oct 19, 2007
Power Train
NOTICED GEAR OIL ON RIGHT REAR AXLE DUST COVER AND BRAKE COMPONENTS. RIGHT REAR AXLE SEAL WAS LEAKING. FIRST NOTICED THE LEAKING SEAL AT 25,600 MILES.
NHTSA ODI #10206274
Mileage unknown · Oct 15, 2007
Structure
TL*THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT STATED THAT THE PAINT WAS MORE GRAY THAN BLUE AROUND THE DOOR JAM AREA OF THE VEHICLE. HE STATED THAT THERE DID NOT APPEAR TO BE THREE LAYERS OF PAINT IN THAT AREA. HE TOOK THE VEHICLE TO THE DEALER AND THEY OFFERED HIM A TRADE AT THE COST OF $3,000. THE CONTACT DECLINED T…
Read full complaint
TL*THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT STATED THAT THE PAINT WAS MORE GRAY THAN BLUE AROUND THE DOOR JAM AREA OF THE VEHICLE. HE STATED THAT THERE DID NOT APPEAR TO BE THREE LAYERS OF PAINT IN THAT AREA. HE TOOK THE VEHICLE TO THE DEALER AND THEY OFFERED HIM A TRADE AT THE COST OF $3,000. THE CONTACT DECLINED THEIR OFFER. THE DEALER REQUESTED THAT NISSAN SEND THEM PICTURES. ONCE THE PICTURES WERE RECEIVED, THE DEALER WAS UNABLE TO FIND ANYTHING WRONG. HOWEVER, THEY DO ACKNOWLEDGE THE FAILURE. THE FAILURE MILEAGE WAS UNKNOWN, BUT THE FAILURE BEGAN WITHIN WEEKS OF THE VEHICLE BEING PURCHASED. THE CURRENT MILEAGE WAS 11,000.
NHTSA ODI #10205657
45,000 miles · Oct 10, 2007
Power Train
REAR AXLE SEALS LEAKED. FLUID GOT ON REAR BRAKES. 2006 NISSAN TITAN SE CREW CAB. *JB
NHTSA ODI #10205371
Mileage unknown · Sep 20, 2007
Electrical System
2006 NISSAN TITAN BATTERY DIED WHILE DRIVING. CUSTOMER STATED THAT HE HAD NO PRIOR INDICATIONS BEFORE THE FAILURE. HE ASKED TO BE REIMBURSED FOR THE BATTERY . *KB THE CONSUMER STATED A BATTERY SHOULD LAST MORE THAN 11 MONTHS. *JB
NHTSA ODI #10203844
Mileage unknown · Jul 29, 2007
Power Train
RIGHT REAR AXLE SEAL LEAKING ON 2006 CC TITAN @ 43,000 MILES.*JB
NHTSA ODI #10197771
13,500 miles · Jul 27, 2007
Power Train
HAD BEEN HEARING A 'CLANK' WHEN PUTTING VEHICLE INTO GEAR, SIMILAR TO WHEN A U-JOINT IS FAILING. WHILE TOWING MY BOAT TRAILER (BOAT WAS IN THE WATER), HAD THE VEHICLE IN 4WD, AND TURNED HARD LEFT TO EXIT THE PARKING SPOT. HEARD A LOUD SNAP IN THE REAR END, THEN HEARD ANOTHER ONE. USED TRUCK TO PULL THE BOAT OUT, BUT THEN DISC…
Read full complaint
HAD BEEN HEARING A 'CLANK' WHEN PUTTING VEHICLE INTO GEAR, SIMILAR TO WHEN A U-JOINT IS FAILING. WHILE TOWING MY BOAT TRAILER (BOAT WAS IN THE WATER), HAD THE VEHICLE IN 4WD, AND TURNED HARD LEFT TO EXIT THE PARKING SPOT. HEARD A LOUD SNAP IN THE REAR END, THEN HEARD ANOTHER ONE. USED TRUCK TO PULL THE BOAT OUT, BUT THEN DISCONNECTED THE TRAILER AND HAD MY FRIEND TOW THE BOAT HOME. TOOK TRUCK TO DEALERSHIP NEXT MORNING, AND THEY REPLACED THE ENTIRE REAR AXLE ASSEMBLY UNDER WARRANTY (THANK GOD!). *TR
NHTSA ODI #10197652
5,900 miles · Jul 18, 2007
Engine And Engine CoolingFire
TL*THE CONTACT OWNS A 2006 NISSAN TITAN. APPROXIMATELY THREE MINUTES AFTER THE CONTACT EXITED THE VEHICLE, FLAMES ERUPTED FROM UNDERNEATH THE HOOD. THE MANUFACTURER INSPECTED THE VEHICLE, BUT REFUSED TO INFORM THE CONTACT OF WHAT CAUSED THE FIRE. THE MANUFACTURER STATED THAT THEY WOULD REPAIR THE VEHICLE UNDER WARRANTY. THE …
Read full complaint
TL*THE CONTACT OWNS A 2006 NISSAN TITAN. APPROXIMATELY THREE MINUTES AFTER THE CONTACT EXITED THE VEHICLE, FLAMES ERUPTED FROM UNDERNEATH THE HOOD. THE MANUFACTURER INSPECTED THE VEHICLE, BUT REFUSED TO INFORM THE CONTACT OF WHAT CAUSED THE FIRE. THE MANUFACTURER STATED THAT THEY WOULD REPAIR THE VEHICLE UNDER WARRANTY. THE CURRENT AND FAILURE MILEAGES WERE 5,900. UPDATED 02-01-08. *KB THE CONSUMER STATED AS OF 08/20/07 HE STILL DOES NOT HAVE THE VEHICLE BACK AND DOES NOT KNOW WHAT DEFECT WAS FOUND IN THE INVESTIGATION. THE CONSUMER STATED THE DEALER SEEMED TO THINK IT WAS THE CONDENSER BELT. UPDATED 02/01/08 *TR
NHTSA ODI #10196749
23,960 miles · Jul 9, 2007
Wheels
NISSAN TITAN -WHEEL SPOKE CRACKED THROUGH ONE WHEEL SPOKE OF THE 18 INCH CHROME ALLOY, 5 SPOKE WHEEL RIM CRACKED IN TWO. THE BRAKE WAS UNSTABLE AND NEAR THE MIDPOINT OF THE SPOKE. IT WAS CLEARLY VISIBLE FROM BOTH SIDES OF THE WHEEL. THERE WAS NO SIGN OF IMPACT OR STRESS THAT MIGHT HAVE CAUSED THE FRACTURE. THE OTHER SPOKES…
Read full complaint
NISSAN TITAN -WHEEL SPOKE CRACKED THROUGH ONE WHEEL SPOKE OF THE 18 INCH CHROME ALLOY, 5 SPOKE WHEEL RIM CRACKED IN TWO. THE BRAKE WAS UNSTABLE AND NEAR THE MIDPOINT OF THE SPOKE. IT WAS CLEARLY VISIBLE FROM BOTH SIDES OF THE WHEEL. THERE WAS NO SIGN OF IMPACT OR STRESS THAT MIGHT HAVE CAUSED THE FRACTURE. THE OTHER SPOKES REMAINED INTACT, BUT THIS WA S A HAZARDOUS SITUATION.*AK
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.
Consequence & remedy
Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.
Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
2006 Nissan Titan Problems, Complaints & Recalls | Skip That Year