← New search

2006 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2006 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

376 reports with mileage · 54 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 194 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 46 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 45 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

14 crash reports10 fire reports7 injury reports

What owners actually said

430 reports
35,000 miles · Aug 20, 2008
EquipmentPower Train

MY DANA AXLE SEALS STARTED LEAKING AT 35,000 MILES. IT GETS ALL OVER THE BRAKES, CAN CAUSE BRAKE FAILURE. NISSAN WARRANTED THE PROBLEM REPLACED ENTIRE REAR AXLE. MANY PEOPLE WITH THIS SAME TRUCK HAVE THE SAME PROBLEM. IT ALMOST SEEMS LIKE 90%. *TR

NHTSA ODI #10239106

20,000 miles · Aug 19, 2008
Power Train

AXLE SEAL LEAKAGE RESULTING IN DIFFERENTIAL OIL GETTING ON REAR BRAKE DISK. *TR

NHTSA ODI #10238884

34,000 miles · Aug 13, 2008
StructureSuspension

VEHICLE DOES NOT COME WITH ADJUSTABLE CAMBER BOLTS INSTALLED FROM MANUFACTURER. MANUFACTURER REFUSES TO REPLACE NOW THAT VEHICLE IS OUT OF 12MTH/12,000 MILE WARRANTY. *TR

NHTSA ODI #10238091

Mileage unknown · Aug 13, 2008
Engine And Engine Cooling

NOISE IN CONDENSER FAN MOTOR. THIS IS 3RD TIME SINCE PURCHASE OF TITAN IN APRIL 2006 THAT I HAVE HAD THIS TRUCK TO DEALER. 1ST TIME, REPLACE A/C CONDENSER, 2ND TIME IN 2007 REPLACE COMPRESSOR, 2ND CONDENSER AND KEPT VEHICLE FOR 3 WEEKS. THIS SUMMER THE CONDENSER MOTOR. THEY SAID HAD RECALL ON IT AND PATCHED A SECTION OF THE MOT…

Read full complaint

NOISE IN CONDENSER FAN MOTOR. THIS IS 3RD TIME SINCE PURCHASE OF TITAN IN APRIL 2006 THAT I HAVE HAD THIS TRUCK TO DEALER. 1ST TIME, REPLACE A/C CONDENSER, 2ND TIME IN 2007 REPLACE COMPRESSOR, 2ND CONDENSER AND KEPT VEHICLE FOR 3 WEEKS. THIS SUMMER THE CONDENSER MOTOR. THEY SAID HAD RECALL ON IT AND PATCHED A SECTION OF THE MOTOR WITH A/C TAPE AND WRAPPED THE WIRING WITH TAPE AND PUT A WEDGE BETWEEN MOTOR AND BRACKET. MY WIFE WAITED TO HAVE IT REPAIRED AND 4 HOURS LATER WENT HOME. I WORK OUT OF TOWN AND I CHECKED THE INTERNET FOR RECALLS AND FOUND MORE THAN JUST THIS PROBLEM WITH THE TRUCK BUT, HAVE NOT BEEN TOLD BY NISSAN OR THE DEALER OF THESE OTHER RECALLS. THE LAST TIME MY TRUCK WAS KEPT FOR 3 WEEKS I REPORTED TO NISSAN THE PROBLEMS AND WAS CUT OFF WHEN I WAS GIVING MY COMPLAINT TO CUSTOMER SERVICE {?}. NEVER HEARD FROM THEM OR THE LOCAL DEALER SPARKS NISSAN.OH YES, I ALSO HAD TO HAVE THE BATTERY REPLACED IN MARCH 2008 AS IT DIED AND WOULD NOT HOLD A CHARGE AND IT WAS ON A WEEKEND AND HAD TO BE REPAIRED BEFORE I LEFT TOWN AND NO WAY FOR MY WIFE TO GO. THE DEALER OWNER HERE DOES NOT CARE ABOUT HIS CUSTOMERS AFTER THE SELL AND EACH TIME SOMEONE ASK ME HOW I LIKE MY TRUCK; I TELL THEM HOW WE HAVE BEEN TREATED AND WHAT PROBLEMS WE HAVE HAD. I SUGGEST STRONGLY THAT THE HIGHWAY TRAFFIC SAFETY ADMIN. CONTACT THESE MANUFACTURES AND ENFORCE THE RECALLS. SOME OF THESE CAN BE FATAL IN AN ACCIDENT. THIS IS ALL UNACCEPTABLE FOR THE AMOUNT OF MONEY THAT IS SPENT ON THE PURCHASE OF A VEHICLE. *TR

NHTSA ODI #10238076

49,000 miles · Aug 12, 2008
Power Train

REAR AXLES SEALS LEAK ONTO THE BRAKES. *TR

NHTSA ODI #10237883

Mileage unknown · Jul 24, 2008
Power Train

REAR AXEL SEALS WENT OUT ON BOTH WHEELS AT THE SAME TIME WITH 37,000 MILES. NISSAN ONLY FIXED BECAUSE OF EXTENDED WARRANTY PURCHASE. NO RENTAL CAR WAS GIVEN ALTHOUGH THE DEFECT WAS THEIRS. *TR

NHTSA ODI #10235582

30,122 miles · Jul 11, 2008
Power Train

REAR AXLE SEALS LEAKING ONTO BRAKES. *TR

NHTSA ODI #10233991

64,000 miles · Jun 26, 2008
Equipment

TL*THE CONTACT OWNS A 2006 NISSAN TITAN. FIVE MINUTES AFTER THE CONTACT STARTED THE VEHICLE, HE NOTICED SMOKE UNDERNEATH THE HOOD. HE SHUT OFF THE VEHICLE AND DISCONNECTED THE BATTERY. THE VEHICLE WAS DRIVEN TO THE DEALER AND THEY DISCOVERED THAT THE COOLANT WIRES, FUSE BOX WIRES, HARNESS WIRES, AND COOLANT UNIT/COMBO SWITCH …

Read full complaint

TL*THE CONTACT OWNS A 2006 NISSAN TITAN. FIVE MINUTES AFTER THE CONTACT STARTED THE VEHICLE, HE NOTICED SMOKE UNDERNEATH THE HOOD. HE SHUT OFF THE VEHICLE AND DISCONNECTED THE BATTERY. THE VEHICLE WAS DRIVEN TO THE DEALER AND THEY DISCOVERED THAT THE COOLANT WIRES, FUSE BOX WIRES, HARNESS WIRES, AND COOLANT UNIT/COMBO SWITCH WERE MELTED AND FUSED TOGETHER. THE DEALER WILL REPLACE THE COOLING FAN AND THE WIRING HARNESS. THE CURRENT AND FAILURE MILEAGES WERE 64,000. UPDATED 062909 *BF THE DEALER STATED THE AC CONDENSER FAN MOTOR HOUSING RUSTED CAUSING THE MOTOR TO SEIZE AND OVERHEAT, LEADING TO THE WIRES BURNING OUT AND SHORTENING. THE CONSUMER RECEIVED A RECALL NOTICE IN THE MAIL FOR THE PROBLEM HE HAD ALREADY EXPERIENCED. NISSAN INFORMED THE CONSUMER THE RECALL WAS ONLY FOR THE CONDENSER FAN PORTION OF THE REPAIR. UPDATED 07/02/09.*JB

NHTSA ODI #10232349

57,000 miles · Jun 15, 2008
Service Brakes, Hydraulic

NOTICED WHEN BRAKING TRUCK STARTED VIBRATING, THOUGHT IT WAS ROTORS GOING BAD UNTIL I LOOKED UNDER MY VEHICLE AND NOTICED BOTH REAR AXLE SEALS WERE WET AND LEAKING. HEARD THROUGH WORD OF MOUTH OF SIMILAR PROBLEMS NOW I HAVE MINE. *TR

NHTSA ODI #10231068

52,000 miles · Jun 1, 2008
Power Train

REAR AXEL SEAL LEAK ON 2006 NISSAN TITAN. CAUGHT PROBLEM BEFORE BRAKE FAILURE. *TR

NHTSA ODI #10229426

Official recalls

5

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V064000 · Latches/locks/linkages:doors:latch

Mar 8, 2006

CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.

Consequence & remedy

Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.

Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.