NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
430 reports26,383 miles · Feb 7, 2011
Electrical SystemEngine And Engine CoolingEquipment
RECALL ID # 08V284000 - EQUIPMENT:ELECTRICAL:AIR CONDITIONER RECALL DATE:JUN 27, 2008 COMPONENT:EQUIPMENT:ELECTRICAL:AIR CONDITIONER MODEL AFFECTED:TITAN UNITS AFFECTED: 180664 RECALL DETAILS RECALL ID # 10V074000 - FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM RECALL DATE:MAR 03, 2010 COMPONENT:FUEL SYSTEM, OTHER:STORAGE:…
Read full complaint
RECALL ID # 08V284000 - EQUIPMENT:ELECTRICAL:AIR CONDITIONER RECALL DATE:JUN 27, 2008 COMPONENT:EQUIPMENT:ELECTRICAL:AIR CONDITIONER MODEL AFFECTED:TITAN UNITS AFFECTED: 180664 RECALL DETAILS RECALL ID # 10V074000 - FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM RECALL DATE:MAR 03, 2010 COMPONENT:FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM MODEL AFFECTED:TITAN UNITS AFFECTED: 340000 RECALL DETAILS RECALL ID # 10V517000 - ENGINE AND ENGINE COOLING RECALL DATE:OCT 28, 2010 COMPONENT:ENGINE AND ENGINE COOLING MODEL AFFECTED:TITAN UNITS AFFECTED: 747480 RECALL DETAILS RECALL ID # 10E019000 - SUSPENSION:FRONT:CONTROL ARM:LOWER ARM RECALL DATE:MAY 20, 2010 COMPONENT:SUSPENSION:FRONT:CONTROL ARM:LOWER ARM MODEL AFFECTED:TITAN UNITS AFFECTED: 1873 RECALL DETAILS RECALL ID # 06V064000 - LATCHES/LOCKS/LINKAGES:DOORS:LATCH RECALL DATE:MAR 08, 2006 COMPONENT:LATCHES/LOCKS/LINKAGES:DOORS:LATCH MODEL AFFECTED:TITAN UNITS AFFECTED: 427 RECALL DETAILS RECALL ID # 07E046000 - EQUIPMENT RECALL DATE:JUL 03, 2007 COMPONENT:EQUIPMENT MODEL AFFECTED:TITAN UNITS AFFECTED: 3500 RECALL DETAILS RECALL ID # 06V459000 - ELECTRICAL SYSTEM RECALL DATE:NOV 30, 2006 COMPONENT:ELECTRICAL SYSTEM MODEL AFFECTED:TITAN UNITS AFFECTED: 96500 RECALL DETAILS I HAVE OWNED THE VEHICLE SINCE 7/2007 AND ONLY RECIEVED 3 OF THESE RECALL LETTERS. SO OF THESE ISSUES ARE JUST NOW POPPING. ONLY 2 OF THE ISSUES HAVE BEEN TAKEN CARE OF. PER THE DEALERSHIP I WOULD BE CONTACTED AND HAVE NOT RECEIVED ANY CALLS TO GET THESE MATTERS TAKEN CARE OF. I FEEL THIS VEHICLE IS UNSAFE SINCE THE ISSUES HAVE NOT BE ADDRESSED.
NHTSA ODI #10381056
68,000 miles · Jan 25, 2011
Tires
TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT WAS DRIVING APPROXIMATELY 55 MPH WHEN THE TIRE PRESSURE WARNING LIGHT ILLUMINATED. THE VEHICLE WAS TAKEN TO THE DEALER WHERE REPAIRS WERE PERFORMED AND THE LIGHT WAS NO LONGER ILLUMINATED. AFTER LEAVING THE DEALER, THE LIGHT RE-ILLUMINATED. THE VEHICLE WAS TAKEN BACK TO THE D…
Read full complaint
TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE CONTACT WAS DRIVING APPROXIMATELY 55 MPH WHEN THE TIRE PRESSURE WARNING LIGHT ILLUMINATED. THE VEHICLE WAS TAKEN TO THE DEALER WHERE REPAIRS WERE PERFORMED AND THE LIGHT WAS NO LONGER ILLUMINATED. AFTER LEAVING THE DEALER, THE LIGHT RE-ILLUMINATED. THE VEHICLE WAS TAKEN BACK TO THE DEALER WHERE THE TECHNICIAN STATED THAT THE TIRE PRESSURE SENSORS WOULD NEED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 68,000.
NHTSA ODI #10378618
54,000 miles · Jan 21, 2011
Power Train
RIGHT REAR AXLE SEAL LEAKING OIL ON TO BRAKE ROTOR REPLACED AXLE SEAL 2006 NISSAN TITAN 4X4 MILES 54,000. *TR
NHTSA ODI #10378206
32,890 miles · Jan 4, 2011
Suspension
WAS DOING NORMAL ROAD DRIVING WHEN I HEARD A LOUD BANG. DID A QUICK VISUAL INSPECTION WHEN I HAD A CHANCE TO STOP BUT DID NOT NOTICE ANYTHING AS I WAS DRIVING AT NIGHT. THE NEXT DAY I LOOKED ONCE AGAIN AND NOTICED A HUMP IN THE BED OF MY TRUCK AND THE SEEMS OF THE BED HAD BEEN SEPARATED. I LOOKED UNDERNEATH THE VEHICLE AND SA…
Read full complaint
WAS DOING NORMAL ROAD DRIVING WHEN I HEARD A LOUD BANG. DID A QUICK VISUAL INSPECTION WHEN I HAD A CHANCE TO STOP BUT DID NOT NOTICE ANYTHING AS I WAS DRIVING AT NIGHT. THE NEXT DAY I LOOKED ONCE AGAIN AND NOTICED A HUMP IN THE BED OF MY TRUCK AND THE SEEMS OF THE BED HAD BEEN SEPARATED. I LOOKED UNDERNEATH THE VEHICLE AND SAW THAT THE LEAF SPRING SHACKLE HAD BUSTED AND WENT THROUGH THE BED OF THE TRUCK. *TR
NHTSA ODI #10374693
105,000 miles · Jan 2, 2011
Power Train
BOTH SIDES OF THE REAR AXLE HAVE BEGUN LEAKING BADLY AND THERE ARE ONLY 105,000 MILES ON THE VEHICLE. THE VEHICLE HAS NOT BEEN ALTERED IN ANY WAY AND IS USED FOR REGULAR USE, NOT A WORK TRUCK. THE LEAK IS SO BAD THAT THE OIL HAS SATURATED THE INSIDE OF THE WHEEL WELL AND THE REAR BRAKE PADS. WHEN I CALLED THE DEALERSHIP ABOUT…
Read full complaint
BOTH SIDES OF THE REAR AXLE HAVE BEGUN LEAKING BADLY AND THERE ARE ONLY 105,000 MILES ON THE VEHICLE. THE VEHICLE HAS NOT BEEN ALTERED IN ANY WAY AND IS USED FOR REGULAR USE, NOT A WORK TRUCK. THE LEAK IS SO BAD THAT THE OIL HAS SATURATED THE INSIDE OF THE WHEEL WELL AND THE REAR BRAKE PADS. WHEN I CALLED THE DEALERSHIP ABOUT THE ISSUE THEY TRIED TO SELL ME THE ENTIRE ASSEMBLY(AXLES, SEALS, BEARINGS, ETC) CLAIMING THAT MECHANICS HAVEN'T BEEN PRESSING THE BEARINGS CORRECTLY. UPON FURTHER RESEARCH ONLINE, IT LOOKS LIKE A LOT OF TITAN OWNERS HAVE BEEN HAVING PROBLEMS WITH THE REAR ENDS LEAKING EVEN AT MUCH EARLIER INTERVALS. BASED ON MY CONVERSATION WITH THE DEALERSHIP IT SOUNDS LIKE NISSAN IS AWARE OF THIS AND TRYING TO SELL THE FIX WHEN PEOPLE COME TO THE DEALERSHIP. *TR
NHTSA ODI #10373787
62,000 miles · Dec 25, 2010
Power Train
POWER TRAIN:AXLE ASSEMBLY:AXLE SHAFT:R/PASSENGER SIDE SEAL LEAKS ONTO BRAKE ROTOR DUST SHIELD , POTENTIAL FOR BRAKE FAILURE WHICH COULD RESULT IN VEHICLE CRASH CAUSING POSSIBLE INJURY OR FATALITY. *TR
NHTSA ODI #10372370
78,000 miles · Dec 22, 2010
Power Train
TRUCK HAS RIGHT REAR AXLE LEAK. NISSAN DEALER WANTS $470 FOR REPAIR. *TR
NHTSA ODI #10372093
87,000 miles · Dec 19, 2010
Service Brakes, Hydraulic
I WAS ROTATING MY TIRES AND NOTICED GEAR OIL ON THE INSIDE OF MY REAR WHEELS. THE GEAR OIL HAS SEEPED OUT OF A FAILED OIL SEAL AND COVERED MY BRAKE PADS AND ROTOR. THIS OIL COULD CAUSE DECREASED BRAKING ABILITY AND INCREASE THE LIKELIHOOD OF A FAILED BRAKE RELATED ACCIDENT. *TR
NHTSA ODI #10371207
53,000 miles · Dec 15, 2010
Suspension
2006 NISSAN TITAN 4X4, WHILE DRIVING ON TRIP WITH YOUNG DAUGHTER HEARD LOUD BANG FROM REAR OF TRUCK. OBSERVED ROAD FOR ANY DEBRIS I MAY HAVE HIT, FOUND NOTHING. PERFORMED QUICK INSPECTION ON SIDE OF ROAD & SAW NOTHING, CONTINUED TRIP & NOTICED BAD RIDE FROM SUSPENSION. REINSPECTED AFTER ARRIVING HOME & FOUND THAT ONE OF THE L…
Read full complaint
2006 NISSAN TITAN 4X4, WHILE DRIVING ON TRIP WITH YOUNG DAUGHTER HEARD LOUD BANG FROM REAR OF TRUCK. OBSERVED ROAD FOR ANY DEBRIS I MAY HAVE HIT, FOUND NOTHING. PERFORMED QUICK INSPECTION ON SIDE OF ROAD & SAW NOTHING, CONTINUED TRIP & NOTICED BAD RIDE FROM SUSPENSION. REINSPECTED AFTER ARRIVING HOME & FOUND THAT ONE OF THE LEAF SPRING SHACKLES HAD SNAPPED IN TWO AND THREW THE LEAF SPRING INTO THE BED OF THE TRUCK CAUSING A HOLE IN THE BED. THE FAILED SHACKLE ALSO CAUSED EXCESSIVE PRESSURE TO THE SHOCK ABSORBER CAUSING IT TO FAIL ALSO. REPLACED THE SHACKLES AND SHOCKS BUT STILL HAVE A BAD RATTLE COMING FROM REAR END. AARG!!!! *TR
NHTSA ODI #10370789
37,000 miles · Dec 4, 2010
Power TrainSuspension
REAR AXLE LEAK - 2006 NISSAN TITAN CC 4WD WITH 39000. DRIVER SIDE REAR AXLE SEAL STARTING LEAKING. CONCERN DUE TO THE PROXIMITY TO BRAKE/BRAKE CALIPER. *TR
NHTSA ODI #10369207
Official recalls
5Oct 28, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Mar 3, 2010
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Jun 27, 2008
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Nov 30, 2006
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Mar 8, 2006
CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.
Consequence & remedy
Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.
Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.