I DIDN'T HAULED ANY HEAVY LOAD IN MY NISSAN TITAN 2006 AT THE TIME IT HAPPENED TO THE BROKEN LEAF SPRING SHACKLE. AS I DRIVING I FELT THE TRUCK HAVE AN ODD MOVING MOTION ON THE ROAD. I PARKED THE TRUCK AND THE TRUCK BED SEEMS LIKE ITS LOP-SIDED WHEN YOU LOOK STRAIGHT TO THE TRUCK BED. I LOOK UNDERNEATH THE TRUCK BED AND SAW …
Read full complaint
I DIDN'T HAULED ANY HEAVY LOAD IN MY NISSAN TITAN 2006 AT THE TIME IT HAPPENED TO THE BROKEN LEAF SPRING SHACKLE. AS I DRIVING I FELT THE TRUCK HAVE AN ODD MOVING MOTION ON THE ROAD. I PARKED THE TRUCK AND THE TRUCK BED SEEMS LIKE ITS LOP-SIDED WHEN YOU LOOK STRAIGHT TO THE TRUCK BED. I LOOK UNDERNEATH THE TRUCK BED AND SAW THE REAR DRIVER SIDE LEAF SPRING SHACKLE BROKEN APART AND PUNCTURED A LARGE SEAM TO THE TOP OF THE TRUCK BED. *TR
NHTSA ODI #10459758
58,776 miles · Feb 29, 2012
Suspension
LEFT REAR LEAF SPRING SHACKLE FRACTURED ON A SMOOTH ROAD, CAUSING THE LEAF SPRING TO IMPACT AND DEFORM THE BED AND DEGRADING HANDLING. *TR
NHTSA ODI #10449900
136,285 miles · Jan 19, 2012
SuspensionUnknown Or OtherWheels
ON A RECALL FOR A FAULTY ECM (ENGINE CONTROL MODULE). THE VEHICLE STALLED AND WOULD NOT START AGAIN, HAD IT TOWED TO DEALER. NISSAN COVERED THIS ECM. DURING THE REPAIR THE MECHANIC NOTED THAT THE REAR AXLE SEALS WERE LEAKING AND RECOMMENDED THAT THEY BE REPAIRED AS SOON AS POSSIBLE. THE COST TO REPAIR WAS ESTIMATED AT $750.0…
Read full complaint
ON A RECALL FOR A FAULTY ECM (ENGINE CONTROL MODULE). THE VEHICLE STALLED AND WOULD NOT START AGAIN, HAD IT TOWED TO DEALER. NISSAN COVERED THIS ECM. DURING THE REPAIR THE MECHANIC NOTED THAT THE REAR AXLE SEALS WERE LEAKING AND RECOMMENDED THAT THEY BE REPAIRED AS SOON AS POSSIBLE. THE COST TO REPAIR WAS ESTIMATED AT $750.00. WHILE WEB SURFING FOR THE REPAIR PROCESS FOR THE SEALS I RAN ACROSS MANY COMPLAINTS CONCERNING THIS PROBLEM WITH THE NISSAN TITAN INCLUDING MODELS FROM 2004 TO PRESENT (2012). BASED ON THE FEEDBACK FROM OTHER TITAN OWNERS, THIS IS A COMMON FLAW WITH THE VEHICLE AND A COSTLY ONE AT THAT. ALSO THIS IS THE FIRST TIME I HAVE EVER WITNESSED REAR AXLE SEALS FAILING IN A VEHICLE. MOST SEEM TO LAST THE LIFE TIME OF THE VEHICLE. I BELIEVE THIS IS A MANUFACTURE'S RESPONSIBLITY DUE TO A DEFECTIVE PARTS CREATING AN UNSAFE AND USELESS MEANS OF TRANSPORTATION. *TT
NHTSA ODI #10444505
38,000 miles · Sep 13, 2011
Suspension
AT 38,000 MILES THE DRIVE SIDE REAR AXLE SEAL ON MY 2006 NISSAN TITAN STARTED LEAKING SPREADING GREASE ALL OVER THE INSIDE OF THE WHEEL. THIS WAS NOT IN ANY WAY DUE TO NEGLECT OF THE VEHICLE, OFF ROAD 4-WHEEL DRIVE DRIVING OR VIA AUTO ACCIDENT AS I DRIVE EXCLUSIVELY ON PAVED ROADS AND THE TRUCK HAS NEVER BEEN IN AN ACCIDENT. I…
Read full complaint
AT 38,000 MILES THE DRIVE SIDE REAR AXLE SEAL ON MY 2006 NISSAN TITAN STARTED LEAKING SPREADING GREASE ALL OVER THE INSIDE OF THE WHEEL. THIS WAS NOT IN ANY WAY DUE TO NEGLECT OF THE VEHICLE, OFF ROAD 4-WHEEL DRIVE DRIVING OR VIA AUTO ACCIDENT AS I DRIVE EXCLUSIVELY ON PAVED ROADS AND THE TRUCK HAS NEVER BEEN IN AN ACCIDENT. I FEEL THIS COULD EASILY HAVE COVERED MY BRAKES WITH GREASE AND OIL AND CAUSED LONGER STOPPING DISTANCES WHICH OF COURSE COULD LEAD TO ACCIDENTS. *TR
NHTSA ODI #10425182
108,000 miles · Jun 27, 2011
StructureSuspension
WHILE DRIVING, HEARD A BANG, DID NOT NOTICE ANY DAMAGE AT FIRST. LATER ONCE THE TRUCK WAS PARKED AT HOME SEEN THE DRIVER SIDE REAR LEAF SPRING WAS PUSHED THROUGH THE BED OF THE TRUCK. (HAVE PICTURES, IF NEEDED) THE PART PUSHED THROUGH THE METAL OF THE BED AS WELL AS THE SPRAY ON BED LINER. TOOK TRUCK TO THE LOCAL GARAGE, WAS AFR…
Read full complaint
WHILE DRIVING, HEARD A BANG, DID NOT NOTICE ANY DAMAGE AT FIRST. LATER ONCE THE TRUCK WAS PARKED AT HOME SEEN THE DRIVER SIDE REAR LEAF SPRING WAS PUSHED THROUGH THE BED OF THE TRUCK. (HAVE PICTURES, IF NEEDED) THE PART PUSHED THROUGH THE METAL OF THE BED AS WELL AS THE SPRAY ON BED LINER. TOOK TRUCK TO THE LOCAL GARAGE, WAS AFRAID TO DRIVE ANY FURTHER THAN JUST A COUPLE MILES. THE MECHANIC STATED THAT HE COULD NOT BELIEVE THAT THIS HAPPENED GIVEN THE YEAR OF THE TRUCK. UPON FURTHER EXAMINATION HE RECOMMENDED THAT THE PASSENGER SIDE BE REPLACED AS WELL, BEFORE IT BROKE ALSO, HE STATED THAT IT WAS VERY THIN METAL. THE REPLACEMENT PART WAS PURCHASED AT THE A DEALER AND I WAS TOLD THAT THEY HAVE HAD NUMEROUS INCIDENTS WHERE THIS PART HAS BROKEN CAUSING SIMILAR DAMAGE. REPAIRS TO THE TRUCK WILL ALSO REQUIRE REPLACING THE TRUCK BED POSSIBLE. THIS TRUCK HAS NOT BEEN TAKEN OFF ROAD NOR HAS IT BEEN USED TO HAUL ITEMS, IT HAS A FIBERGLASS BED COVER ON IT.
NHTSA ODI #10409774
65,000 miles · May 13, 2011
Suspension
2006 NISSAN TITAN SE KING CAB 4X4 OFFROAD BIGTOW. THE DRIVER'S SIDE LEAF SPRING SHACKLE UNRAVELED AT THE WELD AND THE LEAF SPRING SHOT THROUGH THE BOTTOM OF THE BED AND CREATED A BIG HOLE. I CONTACTED NISSAN HQ TO THE CONCLUSION THAT THEY WILL NOT COVER THE REPAIR SINCE I PURCHASED THE TRUCK PRE-OWNED W/ 44,XXX MILES. THIS MA…
Read full complaint
2006 NISSAN TITAN SE KING CAB 4X4 OFFROAD BIGTOW. THE DRIVER'S SIDE LEAF SPRING SHACKLE UNRAVELED AT THE WELD AND THE LEAF SPRING SHOT THROUGH THE BOTTOM OF THE BED AND CREATED A BIG HOLE. I CONTACTED NISSAN HQ TO THE CONCLUSION THAT THEY WILL NOT COVER THE REPAIR SINCE I PURCHASED THE TRUCK PRE-OWNED W/ 44,XXX MILES. THIS MALFUNCTION HAS BEEN REPORTED NUMEROUS TIMES ONLINE AND ON THE NHTSA SITE. IT SEEMS THAT NISSAN IS AWARE OF THE WEAK SHACKLES FOR MODEL YEAR TITANS 2004-2007 BECAUSE THEY REDESIGNED AND STRENGTHENED THE SHACKLE IN 2008 AND UP MODELS. I HAD A LOCAL MECHANIC REPLACE THE SHACKLES W/ 2008+ TITAN SHACKLES AND PLUG/WELD THE HOLE. *TR
NHTSA ODI #10400816
75,639 miles · Apr 14, 2011
Suspension
FRONT SUSPENSION SPRING TOWER WELD BROKE. UPDATED 06/30/11 *BF UPDATED 1/18/2012 *LN *TR
NHTSA ODI #10396498
95,111 miles · Apr 11, 2011
Suspension
TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE VEHICLE WAS PARKED WHEN THE CONTACT NOTICED THAT THE REAR PASSENGER SIDE LEAF SPRING WAS PIERCED THROUGH THE TRUCK BED. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHERE THE FAILURE WAS CONFIRMED. THE MANUFACTURER WAS NOTIFIED AND THE CONTACT WAS TOLD THAT THE VEHICLE WAS NOT INCLU…
Read full complaint
TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE VEHICLE WAS PARKED WHEN THE CONTACT NOTICED THAT THE REAR PASSENGER SIDE LEAF SPRING WAS PIERCED THROUGH THE TRUCK BED. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHERE THE FAILURE WAS CONFIRMED. THE MANUFACTURER WAS NOTIFIED AND THE CONTACT WAS TOLD THAT THE VEHICLE WAS NOT INCLUDED IN ANY RECALLS. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 95,111.
NHTSA ODI #10395479
58,000 miles · Apr 6, 2011
Suspension
TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE VEHICLE WAS PARKED WHEN THE CONTACT OPENED THE TAILGATE AND NOTICED THAT THE LEAF SPRING HAD PIERCED THROUGH THE TRUCK BED. UPON FURTHER INVESTIGATION, THE CONTACT NOTICED THAT THE LEAF SPRING WAS EXTENDED FROM THE DRIVER SIDE REAR STRUT TOWER. THE VEHICLE WAS TAKEN TO AN AUTHORIZED …
Read full complaint
TL* THE CONTACT OWNS A 2006 NISSAN TITAN. THE VEHICLE WAS PARKED WHEN THE CONTACT OPENED THE TAILGATE AND NOTICED THAT THE LEAF SPRING HAD PIERCED THROUGH THE TRUCK BED. UPON FURTHER INVESTIGATION, THE CONTACT NOTICED THAT THE LEAF SPRING WAS EXTENDED FROM THE DRIVER SIDE REAR STRUT TOWER. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHERE IT WAS IN THE PROCESS OF BEING REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 58,000. THE VIN WAS UNAVAILABLE.
NHTSA ODI #10394436
102,000 miles · Mar 10, 2011
Suspension
TL* THE CONTACT OWNS A 2006 NISSAN TITAN XE. THE CONTACT STATED THAT THE LEAP SPRING WAS PUSHED UP INTO THE BED OF THE TRUCK ABNORMALLY AND CAUSING DAMAGE TO THE BED LINER. THE VEHICLE WAS TAKEN TO THE DEALER HOWEVER, THE TECHNICIAN WAS NOT COMFORTABLE PERFORMING THE REPAIRS BECAUSE ADDITIONAL BODY WORK WOULD BE NEEDED. THE VEHI…
Read full complaint
TL* THE CONTACT OWNS A 2006 NISSAN TITAN XE. THE CONTACT STATED THAT THE LEAP SPRING WAS PUSHED UP INTO THE BED OF THE TRUCK ABNORMALLY AND CAUSING DAMAGE TO THE BED LINER. THE VEHICLE WAS TAKEN TO THE DEALER HOWEVER, THE TECHNICIAN WAS NOT COMFORTABLE PERFORMING THE REPAIRS BECAUSE ADDITIONAL BODY WORK WOULD BE NEEDED. THE VEHICLE WAS THEN TAKEN TO AN INDEPENDENT MECHANIC WHO ADVISED THAT THE REAR PASSENGER SIDE SHACKLE, WHICH WAS HOLDING THE LEAF SPRING, WOULD NEED TO BE REPLACED. REPAIRS WERE MADE TO THE VEHICLE FOR THE FAILURE BUT THE BODY DAMAGE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 102,000. UPDATED 03/24/11*LJ
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.
Consequence & remedy
Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.
Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
2006 Nissan Titan Problems, Complaints & Recalls | Skip That Year