← New search

2006 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2006 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

376 reports with mileage · 54 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 194 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 46 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 45 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

14 crash reports10 fire reports7 injury reports

Power Train complaints

194 reports
Clear category filter
89,000 miles · Dec 7, 2012
Power Train

REAR AXLE SEAL FAILURE DESTROYED PARKING BRAKE SHOE PARKING BRAKE WILL NOT ENGAGE. *TR

NHTSA ODI #10487626

51,000 miles · Dec 2, 2012
Power Train

WHILE DRIVING THE TRUCK IN 2WD I HEARD A VERY LOUD CLUNKING (METAL ON METAL) NOISE COMING FORM THE FRONT OF THE TRUCK. AFTER REACHING HOME, I REALIZED THAT THE FRONT AXLE WAS FALLING OUT OF THE FRONT DIFFERENTIAL. I JACKED THE TRUCK UP AND DROPPED THE FRONT DIFF PAN. THIS IS WHERE I REALIZED THAT THE CLIPS HOLD IN THE FRONT A…

Read full complaint

WHILE DRIVING THE TRUCK IN 2WD I HEARD A VERY LOUD CLUNKING (METAL ON METAL) NOISE COMING FORM THE FRONT OF THE TRUCK. AFTER REACHING HOME, I REALIZED THAT THE FRONT AXLE WAS FALLING OUT OF THE FRONT DIFFERENTIAL. I JACKED THE TRUCK UP AND DROPPED THE FRONT DIFF PAN. THIS IS WHERE I REALIZED THAT THE CLIPS HOLD IN THE FRONT AXLE HAVE FAILED AND BROKE IN TWO. THIS IS A HUGE SAFETY CONCERN, HAD I BEEN TRAVELING DOWN THE HIGHWAY I COULD HAVE BEEN KILLED IF THE WHEEL CAME OFF. I RESEARCHED ONLINE AND DISCOVERED THIS A COMMON PROBLEM. *TR

NHTSA ODI #10486753

64,000 miles · Nov 13, 2012
Power Train

WITHIN A PERIOD OF 14-15 MONTHS BOTH REAR AXLE SEAL ASSEMBLIES FAILED, ONE EACH ON PASSENGER AND DRIVER SIDE OF THE REAR AXLE. ACCORDING TO NATIONAL TIRE & BATTERY THE ENTIRE AXLE ASSEMBLY IS REQUIRED TO REPAIR OR REPLACE A SEAL THAT IS LEAKING, AT A COST OF APPROXIMATELY $1000.00 EACH TIME. THIS SEEMS QUITE UNREASONABLE AND EXC…

Read full complaint

WITHIN A PERIOD OF 14-15 MONTHS BOTH REAR AXLE SEAL ASSEMBLIES FAILED, ONE EACH ON PASSENGER AND DRIVER SIDE OF THE REAR AXLE. ACCORDING TO NATIONAL TIRE & BATTERY THE ENTIRE AXLE ASSEMBLY IS REQUIRED TO REPAIR OR REPLACE A SEAL THAT IS LEAKING, AT A COST OF APPROXIMATELY $1000.00 EACH TIME. THIS SEEMS QUITE UNREASONABLE AND EXCESSIVE TO REPLACE AN AXLE THAT IS IN PERFECT OPERATING CONDITION WHEN THE ONLY ISSUE IS WITH A RUBBER BOOT (SEAL) THAT IS LEAKING FLUID. *TR

NHTSA ODI #10484509

99,700 miles · Nov 2, 2012
Power Train

REAR AXLE IS LEAKING ON THE PASSENGER SIDE. *TR

NHTSA ODI #10482943

2,000 miles · Sep 4, 2012
Power Train

2006 WITH 2000 MILES; REAR DIFFERENTIAL MADE A LOUD GEAR WHINE SOUND WHEN IN UN-LOADED DE-CEL. TOOK TITAN BACK TO DEALER. DEALER REPLACED DIFFERENTIAL UNDER WARRANTY (2000 MILES, ONE MONTH AFTER PURCHASE). AT 115,000 MILES IN JULY OF 2011, REPLACED REAR AXLE SEALS (NO WARRANTY). NOW, SEPTEMBER 2012, AT 133,000 MILES. THE SLIP AN…

Read full complaint

2006 WITH 2000 MILES; REAR DIFFERENTIAL MADE A LOUD GEAR WHINE SOUND WHEN IN UN-LOADED DE-CEL. TOOK TITAN BACK TO DEALER. DEALER REPLACED DIFFERENTIAL UNDER WARRANTY (2000 MILES, ONE MONTH AFTER PURCHASE). AT 115,000 MILES IN JULY OF 2011, REPLACED REAR AXLE SEALS (NO WARRANTY). NOW, SEPTEMBER 2012, AT 133,000 MILES. THE SLIP AND BRAKE LIGHTS ILLUMINATE WHEN DIFFERENTIAL GEAR OIL IS COLD. ONCE WARMED UP, LIGHTS GO OUT AND STAY OUT AFTER TITAN IS SHUT DOWN AND RESTARTED WARM. CHANGED DIFFERENTIAL OIL EVERY 7500 MILES WITH 75W 140 SYNTHETIC OIL PER MAINTENANCE GUIDELINES. NO ADDITIVES CALLED FOR OR USED WITH GEAR OIL CHANGES. ACCORDING TO THE OWNER'S MANUAL THE LIGHTS (SLIP AND BRAKE) INDICATE THAT THE ANTI-LOCK BRAKES AND LIMITED SLIP ARE NOT OPERATIONAL WHEN LIGHTS ARE ON. DIFFERENTIAL REPAIR/REPLACEMENT REQUIRED TO RE-GAIN ABS AND LSD FEATURES. NOT SURE IF THE ULTIMATE FAILURE MODE IS 'GRACEFUL' OR NOT. *TR

NHTSA ODI #10473715

65,000 miles · Aug 28, 2012
Power TrainService Brakes

2006 NISSAN TITAN 4X4 CURRENTLY WITH 80,200 MILES. LEFT AND RIGHT REAR AXLE OIL LEAK. AT APPROXIMATELY 65000 MILES, DURING A TRANSMISSION OIL CHANGE AT A NISSAN DEALER, MECHANIC NOTICED THE PASSENGER REAR AXLE WAS LEAKING. THE SERVICE REPRESENTATIVE STATED IT WOULD BE ABOUT $500.00 TO REPAIR. HE ALSO STATED THAT NO RECALL …

Read full complaint

2006 NISSAN TITAN 4X4 CURRENTLY WITH 80,200 MILES. LEFT AND RIGHT REAR AXLE OIL LEAK. AT APPROXIMATELY 65000 MILES, DURING A TRANSMISSION OIL CHANGE AT A NISSAN DEALER, MECHANIC NOTICED THE PASSENGER REAR AXLE WAS LEAKING. THE SERVICE REPRESENTATIVE STATED IT WOULD BE ABOUT $500.00 TO REPAIR. HE ALSO STATED THAT NO RECALL HAD BEEN ISSUED. AFTER HAVING THE ENGINE OIL CHANGED ON JULY 2012, I NOTICED MY DRIVER SIDE REAR AXLE LEAKING NOW. SEVERAL SIMILAR ISSUES HAVE BEEN POSTED ONLINE. NISSAN SHOULD PUSH THE MANUFACTURE TO HAVE THIS HAZARDOUS ISSUE RESOLVED VERY SOON AND NISSAN SHOULD REPLACE THE SEAL AT NO COST OR AT A LOW DISCOUNTED PRICE. *TR

NHTSA ODI #10472804

84,000 miles · Aug 24, 2012
Engine And Engine CoolingPower Train

MY 2006 TITAN STARTED VIBRATING LIKE RUNNING OVER RUMBLE STRIPS ON SIDE OF HIGHWAY. TOOK STRAIGHT TO DEALERSHIP. WAS TOLD THAT THE COOLING SYSTEM SPLIT AND CONTAMINATED THE TRANSMISSION. I HAD TO HAVE THE TRANSMISSION AND RADIATOR REPLACED $7313.56. THERE WAS NO WARNING OR ANYTHING. AFTER READING MANY COMPLAINTS FOR THE SAME THI…

Read full complaint

MY 2006 TITAN STARTED VIBRATING LIKE RUNNING OVER RUMBLE STRIPS ON SIDE OF HIGHWAY. TOOK STRAIGHT TO DEALERSHIP. WAS TOLD THAT THE COOLING SYSTEM SPLIT AND CONTAMINATED THE TRANSMISSION. I HAD TO HAVE THE TRANSMISSION AND RADIATOR REPLACED $7313.56. THERE WAS NO WARNING OR ANYTHING. AFTER READING MANY COMPLAINTS FOR THE SAME THING ON OTHER NISSAN VEHICLES, THERE NEEDS TO BE AN INVESTIGATION AND A RECALL ON THE COOLING SYSTEM THAT CAN CAUSE THIS AMOUNT OF DAMAGE. *TR

NHTSA ODI #10472357

85,873 miles · Jul 9, 2012
Power Train

HAD TRUCK IN SHOP FOR EXHAUST PIPE FALLING OFF AND IT WAS BROUGHT TO MY ATTENTION THAT BOTH THE LEFT AND RIGHT REAR AXEL SEALS AND BEARINGS ARE BAD AND NEED TO BE REPLACED. THE AXEL HAD BEEN LEAKING FLUID ONTO MY TIRES AND BRAKES WHICH COULD HAVE RESULTED IN BRAKE FAILURE OR FIRE. NISSAN WILL NOT WARRANTY THE REAR AXEL REPAIRS. …

Read full complaint

HAD TRUCK IN SHOP FOR EXHAUST PIPE FALLING OFF AND IT WAS BROUGHT TO MY ATTENTION THAT BOTH THE LEFT AND RIGHT REAR AXEL SEALS AND BEARINGS ARE BAD AND NEED TO BE REPLACED. THE AXEL HAD BEEN LEAKING FLUID ONTO MY TIRES AND BRAKES WHICH COULD HAVE RESULTED IN BRAKE FAILURE OR FIRE. NISSAN WILL NOT WARRANTY THE REAR AXEL REPAIRS. THIS IS THE SECOND NEW NISSAN FACTORY AXEL TO BE INSTALLED ON THIS VEHICLE SINCE PURCHASED NEW IN 2006. IT IS CURRENTLY HAVING THE REAR SEALS AND BEARINGS REPLACED AT MY EXPENSE. THIS SEEMS TO BE A COMMON PROBLEM WITH THE NISSAN TITAN MODEL AND SHOULD BE RECALLED. *TR

NHTSA ODI #10464691

91,000 miles · Jun 11, 2012
Power Train

NOTICED THE DRIVERS SIDE REAR AXLE SEAL IS LEAKING FLUID. COULD POTENTIALLY CAUSE THE AXLE TO SEIZE AND/OR BRAKES TO FAIL. THIS IS A MAJOR SAFETY ISSUE AND SHOULD BE RECALLED. LUCKILY I HAD A MECHANIC NOTICE IT BEFORE I GOT INTO AN ACCIDENT. THIS IS A DANGEROUS AND EXPENSIVE PROBLEM THAT SHOULD BE COVERED BY THE MANUFACTURER…

Read full complaint

NOTICED THE DRIVERS SIDE REAR AXLE SEAL IS LEAKING FLUID. COULD POTENTIALLY CAUSE THE AXLE TO SEIZE AND/OR BRAKES TO FAIL. THIS IS A MAJOR SAFETY ISSUE AND SHOULD BE RECALLED. LUCKILY I HAD A MECHANIC NOTICE IT BEFORE I GOT INTO AN ACCIDENT. THIS IS A DANGEROUS AND EXPENSIVE PROBLEM THAT SHOULD BE COVERED BY THE MANUFACTURER DUE TO POOR QUALITY PARTS. *TR

NHTSA ODI #10461173

72,000 miles · May 9, 2012
Power Train

BOTH REAR AXLE SEALS ARE LEAKING AND NEED REPLACED. I HAVE NEVER PULLED ANYTHING WITH THIS TRUCK AND AT 70,000 OR EVEN SOONER, I'M NOT SURE WHEN IT STARTED LEAKING, YOU SHOULD NOT HAVE TO PAY FOR REPLACE REAR AXLE SEALS. *TR

NHTSA ODI #10457902

Official recalls

5

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V064000 · Latches/locks/linkages:doors:latch

Mar 8, 2006

CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.

Consequence & remedy

Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.

Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.