UPON FILLING UP MY GAS TANK THERE IS A STRONG ODOR OF GASOLINE. THIS BECOMES REALLY BAD WHEN PARKED IN MY GARAGE. WE HAVE 2 SMALL CHILDREN SO WANT TO SOLVE THIS AS SOON AS POSSIBLE.
2008 MERCEDES-BENZ Amg E63
Owner reports · Recalls · Investigations
Limited comparison data
There is not enough comparable history to draw a useful model-year comparison.
About this comparison →How this year compares
Owner complaints by model year
Compare all Amg E63 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 14 of 15 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel/propulsion System. Review the 10 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Fuel System, Gasoline. Review the 4 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Air Bags. Review the 1 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
15 reportsLEAKY FUEL SENDING UNIT. I BROUGHT MY 2008 E63 AMG INTO MERCEDES OF BOSTON FOR TO REPAIR A LEAKING FUEL SENDING UNIT AROUND THE SPRING OF 2015. I REALIZE THIS WAS AN ISSUE FOR MANY E CLASS AND WAS BEING INVESTIGATED BY NHTSA. I SPECIFICALLY ASKED MY SERVICE ADVISOR IF MERCEDES WAS AT LEAST COVERING PART OF THE REPAIR. HE SAID T…
Read full complaint
LEAKY FUEL SENDING UNIT. I BROUGHT MY 2008 E63 AMG INTO MERCEDES OF BOSTON FOR TO REPAIR A LEAKING FUEL SENDING UNIT AROUND THE SPRING OF 2015. I REALIZE THIS WAS AN ISSUE FOR MANY E CLASS AND WAS BEING INVESTIGATED BY NHTSA. I SPECIFICALLY ASKED MY SERVICE ADVISOR IF MERCEDES WAS AT LEAST COVERING PART OF THE REPAIR. HE SAID THERE WAS NO WARRANTY COVERAGE ON IT. I PAID $900 FOR THE REPAIR. I JUST FOUND OUT ON THE NHTSA THAT MERCEDES GAVE AN EXTENDED WARRANTY COVERAGE FOR FUEL RELATED PARTS FOR 15 YEARS AS OF SEPTEMBER 2014. MERCEDES IS DELIBERATELY HIDING THESE DETAILS FROM CONSUMERS. NO NOTIFICATIONS WAS EVER SENT. NO REFUNDS OFFERED.
MY VEHICLE WAS HIT ON THE DRIVERS SIDE THE IMPACT WAS TO THE SIDE FRONT QUARTER PANEL (FROM THE LEFT TIRE TO THE FRONT LEFT BUMPER). AS A RESULT OF THE IMPACT THE DRIVERS SIDE CURTAIN AIRBAG AND THE DRIVERS SIDE PASSENGER DOOR AIRBAG DEPLOYED (NO PASSENGER). HOWEVER, THE DRIVERS DOOR AND THE DRIVERS SEAT BOOSTER AIRBAG DID NOT D…
Read full complaint
MY VEHICLE WAS HIT ON THE DRIVERS SIDE THE IMPACT WAS TO THE SIDE FRONT QUARTER PANEL (FROM THE LEFT TIRE TO THE FRONT LEFT BUMPER). AS A RESULT OF THE IMPACT THE DRIVERS SIDE CURTAIN AIRBAG AND THE DRIVERS SIDE PASSENGER DOOR AIRBAG DEPLOYED (NO PASSENGER). HOWEVER, THE DRIVERS DOOR AND THE DRIVERS SEAT BOOSTER AIRBAG DID NOT DEPLOY. RESULTING IN INJURY TO MY LEFT KNEE, LEFT HIP, LEFT RIBS, LEFT SHOULDER (SURGERY PENDING), LATERAL WHIPLASH AND CONCUSSION. I HAVE FILED A CLAIM WITH MBNA. IF THE PASSENGER DRIVER SIDE DOOR AIR BAG DEPLOYED WITH NO PASSENGER THEN THE DRIVERS DOOR AIRBAG MUST HAVE MALFUNCTIONED. THE ACCIDENT TOOK PLACE IN WEST LOS ANGELES AT THE INTERSECTION OF MANCHESTER AVE AND EMERSON. POLICE AND PARAMEDICS WERE CALLED AND I WAS TRANSPORTED TO THE LOCAL HOSPITAL. SURGERY IS PENDING FOR MY LEFT SHOULDER AND POSSIBLY LEFT KNEE. *TR
AFTER REFUELING MY CAR'S GAS TANK I BEGAN TO NOTICE SOME SORT OF GAS LEAKAGE. IT'S ESPECIALLY PRONOUNCED WHEN THE CAR IS PARKED IN THE GARAGE SINCE THE FUME IS UNMISTAKABLE. THERE IS APPARENTLY A FUEL LEAKAGE NEAR THE REAR TIRE (DRIVER'S SIDE). I'M CONCERNED THAT IF THERE WERE ANYTHING IN THE GARAGE THAT IS IGNITED IT WOULD C…
Read full complaint
AFTER REFUELING MY CAR'S GAS TANK I BEGAN TO NOTICE SOME SORT OF GAS LEAKAGE. IT'S ESPECIALLY PRONOUNCED WHEN THE CAR IS PARKED IN THE GARAGE SINCE THE FUME IS UNMISTAKABLE. THERE IS APPARENTLY A FUEL LEAKAGE NEAR THE REAR TIRE (DRIVER'S SIDE). I'M CONCERNED THAT IF THERE WERE ANYTHING IN THE GARAGE THAT IS IGNITED IT WOULD CAUSE SOME TERRIBLE INCIDENT. AFTER I BROUGHT MY CAR IN FOR SERVICE I FOUND OUT THAT THE FUEL SENDER UNIT NEEDS TO BE REPLACED ALONG WITH A RELATED GASKET. THIS TYPE OF PROBLEM SHOULD NOT EXPERIENCE FAILURE AT THIS LOW MILEAGE. *TR
OWNED THE CAR FOR OVER 1 YEAR, NOTICED A PRONOUNCED SMELL OF GASOLINE AFTER FILLING UP AT A LOCAL SERVICE STATION. THOUGHT IT WAS A SPILL, SMELL GOT STRONGER OVER THE NEXT 10 MILES, PARKED THE CAR IN THE GARAGE, WHERE THE SMELL CONTINUED TO INCREASE TO THE POINT I COULD SMELL IT IN THE BEDROOMS ABOVE THE GARAGE. TOOK CAR TO LOCA…
Read full complaint
OWNED THE CAR FOR OVER 1 YEAR, NOTICED A PRONOUNCED SMELL OF GASOLINE AFTER FILLING UP AT A LOCAL SERVICE STATION. THOUGHT IT WAS A SPILL, SMELL GOT STRONGER OVER THE NEXT 10 MILES, PARKED THE CAR IN THE GARAGE, WHERE THE SMELL CONTINUED TO INCREASE TO THE POINT I COULD SMELL IT IN THE BEDROOMS ABOVE THE GARAGE. TOOK CAR TO LOCAL MERCEDES SPECIALIST WHO REMOVED THE INSPECTION PLATES UNDER THE REAR PASSENGER SEATS. DRIVER SIDE REVEALED A LARGE POOLING OF GASOLINE (APPROX 8 FL OZ) AROUND THE FUEL TANK APPARATUS. CAR IS NOT SAFE TO DRIVE, AND REQUIRED $1100 TO REPLACE THE PART. *TR
ON JULY 30TH, 2014 I FUELED MY 2008 MERCEDES E63 AMG IN THE SAME MANNER AS I HAVE FOR THE PAST 3 YEARS OF OWNERSHIP. WHEN I PARKED MY VEHICLE IN THE GARAGE AND CLOSED THE DOOR I NOTICED A FAINT ODOR OF GASOLINE. I THOUGHT IT WAS JUST THE EXHAUST FUME BUILT UP IN THE ENCLOSED ENVIRONMENT. THE NEXT DAY WHEN I CHECKED, THERE WA…
Read full complaint
ON JULY 30TH, 2014 I FUELED MY 2008 MERCEDES E63 AMG IN THE SAME MANNER AS I HAVE FOR THE PAST 3 YEARS OF OWNERSHIP. WHEN I PARKED MY VEHICLE IN THE GARAGE AND CLOSED THE DOOR I NOTICED A FAINT ODOR OF GASOLINE. I THOUGHT IT WAS JUST THE EXHAUST FUME BUILT UP IN THE ENCLOSED ENVIRONMENT. THE NEXT DAY WHEN I CHECKED, THERE WAS AN OVERWHELMING ODOR OF GASOLINE. FUMES WERE SO STRONG I COULD CLEARLY SMELL IT FROM MY FLOOR APARTMENT. LUCKILY MY NEIGHBOR WERE AWAY ON VACATION. THE SMELL OUTSIDE THE ENTRY WAY INTO THE GROWERS WAS SO STRONG IT STUNG MY EYES. KNOWING THE VOLATILITY GAS VAPORS I IMMEDIATELY OPENED THE GROWERS DOOR. WHEN I LOOKED UNDER THE REAR WHEEL ARCH OF THE DRIVER SIDE I SAW A PUDDLE ODD GASOLINE AND INTERMITTENT DROPS OF GASOLINE COMING DOWN FROM THE FUEL TANK AREA. THE GASOLINE DID NOT STOP LEAKING UNTIL I DRIVE IT TO ABOUT 3/4 FULL. IT TOOK 2 WEEKS FOR THE SMELL OF GASOLINE TO DISSIPATE FROM THE INTERIOR. I AM AWARE OF THE CLASS ACTION LAWSUIT AGAINST MERCEDES FOR THIS VERY SAME PROBLEM. *TR
I PURCHASED A 2008 E63 MERCEDES BENZ IN DECEMBER 2013. SINCE THE DATE OF PURCHASE I HAVE NOTICED A STRONG ODOR AND SMELL OF GASOLINE UPON FUELING THE AUTOMOBILE(BOTH INSIDE AND OUTSIDE OF THE VEHICLE). THIS ODOR PROGRESSIVELY GOT STRONGER UNTIL I WAS UNABLE TO CLOSE MY GARAGE DUE TO THE FUMES AND THE FEAR FOR MY SAFETY. I TOOK T…
Read full complaint
I PURCHASED A 2008 E63 MERCEDES BENZ IN DECEMBER 2013. SINCE THE DATE OF PURCHASE I HAVE NOTICED A STRONG ODOR AND SMELL OF GASOLINE UPON FUELING THE AUTOMOBILE(BOTH INSIDE AND OUTSIDE OF THE VEHICLE). THIS ODOR PROGRESSIVELY GOT STRONGER UNTIL I WAS UNABLE TO CLOSE MY GARAGE DUE TO THE FUMES AND THE FEAR FOR MY SAFETY. I TOOK THE CAR TO A MERCEDES BENZ DEALER (LUCKILY) TO HAVE IT CHECKED OUT PRIOR TO A ROAD TRIP ON 7/2/2014 AND IT WAS DETERMINED THERE WAS A LEAK IN THE FUEL TANK AND SENDING UNIT (S). THE TECHNICIANS AT THE MERCEDES BENZ DEALERSHIP INDICATED TO ME THAT THE VEHICLE WAS UNSAFE TO DRIVE AND OPERATE. I HAVE DISCOVERED THAT THIS PARTICULAR ISSUE IS COMMON TO MY PARTICULAR VEHICLE MAKE, MODEL AND YEAR (A RECALL OR CLASS ACTION LAWSUIT HAS BEEN DONE AGAINST MB FOR THIS PROBLEM). I HAD THE REPAIRS DONE AT MERCEDES BENZ BUT WAS CHARGED FOR THE REPAIRS. I SEEK TO RECOVER THE REPAIR COSTS ASSOCIATED WITH THIS INCIDENCE. PLEASE CONTACT ME IMMEDIATELY AS I NEED GUIDANCE AND INFORMATION REGARDING THIS SITUATION. *TR
FILLED THE VEHICLE UP WITH GAS LAST NIGHT 5/14/13 AND AFTER LEAVING WORK TODAY NOTICED AN EXTREME ODOR OF GASOLINE IN THE PASSENGER COMPARTMENT, AND ALSO A VERY STRONG ODOR OF GAS AROUND THE VEHICLE EXTERIORS. *TR
REFERENCE NHTSA ACTION NUMBER: PE12001. I PURCHASED THIS VEHICLE USED IN DECEMBER 2012. ONE DAY AFTER FILLING UP WITH FUEL I PARKED THE CAR IN MY GARAGE. THE NEXT DAY I CAME OUT TO MY GARAGE AND THERE WAS A STRONG SMELL OF GASOLINE. WHEN I GOT INSIDE OF MY CAR THE SMELL GOT MUCH STRONGER AND IT WAS UNBEARABLE. I COULD NOT FIND A…
Read full complaint
REFERENCE NHTSA ACTION NUMBER: PE12001. I PURCHASED THIS VEHICLE USED IN DECEMBER 2012. ONE DAY AFTER FILLING UP WITH FUEL I PARKED THE CAR IN MY GARAGE. THE NEXT DAY I CAME OUT TO MY GARAGE AND THERE WAS A STRONG SMELL OF GASOLINE. WHEN I GOT INSIDE OF MY CAR THE SMELL GOT MUCH STRONGER AND IT WAS UNBEARABLE. I COULD NOT FIND ANY LEAKS INSIDE OR OUTSIDE OF THE VEHICLE. I HAD TO DRIVE TO WORK AND THIS WAS THE ONLY CAR AVAILABLE. THIS WAS IN THE DEAD OF WINTER AND I HAD TO DRIVE WITH THE WINDOWS DOWN BECAUSE THE GAS SMELL AND FUMES WERE UNBEARABLE. I HAD A TERRIBLE HEADACHE FOR THE REST OF THE DAY. I LEFT MY CAR WITH THE WINDOWS ROLLED DOWN TO HELP AIR IT OUT. WHEN I RETURNED HOME I DID SOME RESEARCH ONLINE AND FOUND OUT THIS IS A FAR TOO COMMON PROBLEM WITH THE W211 CHASSIS MERCEDES BENZ. PER THE INFORMATION ONLINE I WAS INSTRUCTED TO REMOVE MY REAR PASSENGER SEAT AND CHECK THE FUEL SENDING UNITS UNDERNEATH THE SEATS. SURE ENOUGH WHEN I REMOVED THE COVER OFF THE DRIVERS SIDE FUEL SENDING UNIT THERE WAS A POOL OF GASOLINE! I CLEANED UP ALL OF THE GASOLINE AND LET IT DRY OUT. FROM THIS POINT ON I HAVE NOT FILLED UP MY GAS TANK MORE THAN 3/4 JUST TO KEEP THIS FROM HAPPENING AGAIN. FUEL POOLING INSIDE OF THE CABIN IS DANGEROUS AND UNHEALTHY. MERCEDES BENZ DENIES THAT THIS IS A PROBLEM AND WILL NOT COVER THE COST OF REPLACING/FIXING THE DEFECTIVE FUEL SENDING UNITS. THERE ARE HUNDREDS IF NOT THOUSANDS OF OTHERS THAT HAVE THIS ISSUE. PLEASE DO SOMETHING TO GET THIS RESOLVED. I HAVE PICTURES OF THE FUEL POOLING INSIDE OF THE CABIN. *TR
A STRONG FUEL ODOR IS PRESENT INSIDE AND OUTSIDE THE VEHICLE AFTER A FULL FILL-UP. THE ODOR DISSIPATES AFTER ABOUT 1/8 OF A TANK OF GASOLINE IS CONSUMED. THESE SYMPTOMS RELIABLY REOCCUR EACH TIME THE FUEL TANK IS COMPLETELY REFILLED. THE ODOR IS NOT PRESENT AS LONG AS THE TANK IS NOT FILLED PAST 7/8 CAPACITY. THE VEHICLE HAS …
Read full complaint
A STRONG FUEL ODOR IS PRESENT INSIDE AND OUTSIDE THE VEHICLE AFTER A FULL FILL-UP. THE ODOR DISSIPATES AFTER ABOUT 1/8 OF A TANK OF GASOLINE IS CONSUMED. THESE SYMPTOMS RELIABLY REOCCUR EACH TIME THE FUEL TANK IS COMPLETELY REFILLED. THE ODOR IS NOT PRESENT AS LONG AS THE TANK IS NOT FILLED PAST 7/8 CAPACITY. THE VEHICLE HAS NOT BEEN INSPECTED BY A MERCEDES-BENZ DEALERSHIP AND NO PARTS HAVE BEEN REPLACED TO ADDRESS THIS PROBLEM. CURRENT MILEAGE IS APPROXIMATELY 72,500. *TR
Official recalls
324V874000 · Visibility:sun/moon Roof Assembly
Nov 19, 2024
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.
Consequence & remedy
Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.
Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.
22V954000 · Visibility:sun/moon Roof Assembly
Dec 23, 2022
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.
Consequence & remedy
Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.
Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.
19V918000 · Visibility:sun/moon Roof Assembly
Dec 20, 2019
Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf
Consequence & remedy
Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.
Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1EA13003 · Fuel Leakage From The Fuel Tank
Opened Mar 15, 2013 · Closed Dec 19, 2014
Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Additional source detail variants (6)
Fuel System, Gasoline:delivery:fuel Pump
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Fuel System, Gasoline:delivery
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Fuel System, Gasoline
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Fuel System, Gasoline:storage
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Fuel System, Gasoline:storage:tank Assembly
The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un
Illustration