NHTSA owner reports · September 18, 2026 snapshot.
Official recalls
7Nov 29, 2018
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2015-2016 Mercedes Benz C300, 2017-2019 C300 Cabrio, C300 Coupe, C63 Cabrio, 2015 C63S AMG, 2018-2019 C300, C350e, C63 AMG, C63S AMG Cabrio, 2018 C63 AMG Cabrio, C63 AMG Coupe, C63S AMG, C63S AMG Coupe, E300, E400 Cabrio, E400 Coupe, 2019 CLS450, E450 Cabrio, and E450 Coupe rear-wheel drive vehicles. A locknut in the steering rack may break under high load, possibly causing the steering to become stuck in one position.
Consequence & remedy
Consequence: A car that cannot be properly steered has an increased risk of a crash.
Remedy: MBUSA will notify owners, and dealers will replace the steering rack, free of charge. The recall began August 23, 2019. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2019080012.
Nov 27, 2018
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2018 C300 Cabriolet, C300 Coupe, C300 4Matic Cabriolet, C300, C300 4Matic Coupe, C300 4Matic, C43 AMG Cabriolet, C43 AMG Coupe, C63 S AMG Cabriolet, C350e Plug-In Hybrid, C63 AMG Cabriolet, C63 AMG Coupe, C63 S AMG Coupe, C63 AMG, C63 S AMG, 2018-2019 GLC300 4Matic Coupe, GLC300, GLC63 AMG Coupe, GLC300 4Matic, GLC350e Plug-In Hybrid, GLC43 AMG Coupe, GLC43 AMG, GLC63 S AMG Coupe, and GLC63 AMG vehicles equipped with Audio 20 head units and automatic child seat recognition. The status of the passenger side air bag may not display correctly.
Consequence & remedy
Consequence: If the passenger air bag is incorrectly displayed as 'ON' when it is not, a front seat passenger may be unaware that the air bag will not deploy in the event of a crash, increasing their risk of injury.
Remedy: MBUSA will notify owners, and dealers will update the audio head unit software, free of charge. The recall began January 3, 2019. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2018120009.
Sep 11, 2018
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2018 Mercedes-Benz C300, C300 4MATIC, C63 AMG, and C63S AMG vehicles. Incorrect bonding of the rear window may cause the window to loosen and detach from the vehicle.
Consequence & remedy
Consequence: If the window detaches from the vehicle, it can become a road hazard, increasing the risk of a crash.
Remedy: MBUSA will notify owners, and dealers will rework the rear window bonding, free of charge. The recall is expected to begin November 2, 2018. Owners may contact MBUSA customer service at 1-800-367-6372.
Jul 10, 2018
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2017-2018 Mercedes C300 Cabriolet, C300 4Matic Cabriolet, C43 AMG Cabriolet, C63S AMG Cabriolet, and C63 AMG Cabriolet vehicles. Due to a bonding issue introduced in the production process, the rear beltline trim may separate from the vehicle.
Consequence & remedy
Consequence: If the beltline trim were to separate from the vehicle while driving, it could become a road hazard, increasing the risk of a crash.
Remedy: MBUSA will notify owners, and dealers will inspect the rear beltline trim and replace the trim if necessary, free of charge. The recall began on September 21, 2018. Owners may contact MBUSA customer service at 1-800-367-6372.
Mar 29, 2018
Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2017-2018 C43 AMG 4Matic Coupe, C300 Coupe, C300 4Matic Coupe, C300 4Matic Cabriolet, C300 Cabriolet, C43 AMG 4Matic Cabriolet and C63S AMG Cabriolet, 2017 C63 AMG Cabriolet, C63S AMG Coupe and C63 AMG Coupe, 2018 E400 Coupe and E400 4Matic Coupe vehicles. The seatbacks of the front seats may not properly lock on the right side of the seat.
Consequence & remedy
Consequence: If the seatback does not properly lock, in the event of a crash, the seatbacks may fold forward, increasing the risk of injury.
Remedy: MBUSA will notify owners, and dealers will inspect the locking of the seatbacks, replacing the seatbacks lock, as necessary, free of charge. The recall is expected to begin May 25, 2018. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2018040007.
Mar 6, 2018
Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2018 Mercedes Benz C43 AMG, C63S AMG, E63 S AMG Sedan, and E63S AMG Stationwagon vehicles fitted with AMG performance seats. The backrest rail and backrest fitting may not be properly welded on the driver and front passenger seats.
Consequence & remedy
Consequence: The incorrect welding may result in the seats failing in the event of a crash, increasing the risk of injury.
Remedy: MBUSA will notify owners, and dealers will inspect the welds of the backrest frames, replacing the backrests as necessary, free of charge. The recall is expected to begin May 4, 2018. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2018060001.
Oct 6, 2017
Mercedes-Benz USA, LLC. (MBUSA) is recalling these vehicles: 2014-2018 CLA250, CLA250 4Matic, CLA45 AMG 4Matic, 2015-2018 GLA250, GLA250 4Matic, GLA45 AMG 4Matic, C300 4Matic, C63S AMG, 2012-2014 C250, C350, C300 4Matic, E550 4Matic, 2013-2014 C63 AMG, 2012-2015 C250 Coupe, C350 Coupe, C63 AMG Coupe, 2013-2015 C350 4Matic Coupe, GLK250 4Matic BlueTec, GLK350, GLK350 4Matic, 2016-2017 C350e, C43 AMG, 2015 C400 4Matic, 2016-2018 C63 AMG, GLC300, GLC300 4Matic, 2017-2018 C300 Coupe, C300 4Matic Coupe, C43 AMG, C63 AMG Coupe, C63S AMG Coupe, C300 Cabriolet, C300 4Matic Cabriolet, C43 AMG Cabriolet, C63 AMG Cabriolet, C63S AMG Cabriolet, GLC300 4Matic Coupe, GLC43 AMG, GLC43 AMG Coupe, 2014 E350 Coupe, E350 4Matic Coupe, E350 Cabriolet, E400 Hybrid, 2015-2017 E400 Coupe, E400 4Matic Coupe, E400 Cabriolet, 2014-2017 E550 Coupe, E550 Cabriolet, B250e, 2014-2016 E250 BlueTec, E63 AMG 4Matic Wagon, 2012-2013 E350 BlueTec, 2012-2016 E350, E350 4Matic, 2015-2016 E400, E400 4Matic, 2012 E63 AMG, 2014-2015 E250 4Matic BlueTec, 2013-2016 E350 Wagon, 2017 GLC300d 4Matic, and 2018 GLC350e 4Matic. The driver's air bag may unexpectedly deploy due to insufficient grounding of the steering components if an electrostatic discharge occurs and the air bag clockspring is broken.
Consequence & remedy
Consequence: If the driver air bag inadvertently deploys, it can increase the risk of injury and a crash.
Remedy: MBUSA will notify owners, and dealers will add sufficient grounding to the steering components, free of charge. The recall began in December 6, 2017. Owners may contact MBUSA customer service at 1-877-496-3691.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1EA21002 · Desiccated Air Bag Inflator Rupture
Opened Sep 17, 2021 · No close date supplied
Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Additional source detail variants (2)
Air Bags:frontal:driver Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.