Halcore Group, Inc. (Halcore) is recalling certain model year 2013-2016 Horton ambulances, models 453, 457, 503, 553, 603, and 623, manufactured November 29, 2013, to March 1, 2016. The affected vehicles may have an improperly sealed Cool-Tech air-conditioning condenser controller wire harness that can allow water to enter the controller housing.
Consequence & remedy
Consequence: If water gets into the controller housing, the controller may short circuit, increasing the risk of an electrical fire.
Remedy: Halcore will notify owners, and dealers will replace the Cool-Tech condenser fan controller assembly, free of charge. Halcore issued an interim notification to owners on September 9, 2016. The recall began on October 26, 2016. Owners may contact Horton customer service at 1-614-317-9856, or by email at warranty@hortonambulance.com
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
0
No exact-year investigations in this snapshot.