← New search

2012 GMC Sierra 1500

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2012 GMC Sierra 1500 do not stand out strongly from the model-year median of 181.

About this comparison →

When problems were reported

Mileage at the reported incident

67 reports with mileage · 40 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 42 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Structure. Review the 21 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 8 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

4 crash reports0 fire reports1 injury reports

Air Bags complaints

42 reports
Clear category filter
220,000 miles · Jun 15, 2021
Air Bags

Takata recall. The contact owns a 2012 GMC Sierra 1500. The contact stated that the air bag warning light was illuminated. The contact took the vehicle to the local dealer, where it was diagnosed with needing the passenger’s side air bag to be replaced. The vehicle was not yet repaired. The contact stated she later received noti…

Read full complaint

Takata recall. The contact owns a 2012 GMC Sierra 1500. The contact stated that the air bag warning light was illuminated. The contact took the vehicle to the local dealer, where it was diagnosed with needing the passenger’s side air bag to be replaced. The vehicle was not yet repaired. The contact stated she later received notification of NHTSA Campaign Number: 21V051000 (Air Bags) however, the part to do the recall repair was unavailable. The contact took the vehicle to the local dealer and it was confirmed that the part was not yet available. The contact stated that the manufacturer had exceeded a reasonable amount of time for the recall repair. The manufacturer was made aware of the issue. VIN tool confirms part not available. The failure mileage was approximately 220,000.

NHTSA ODI #11420984

Mileage unknown · Jun 8, 2021
Air Bags

Takata Recall. The contact owns a 2012 GMC Sierra 1500. The contact received notification of NHTSA Campaign Number: 21V054000 (Air Bags) however, the part to do the recall repair was unavailable. The contact took the vehicle to the local dealer and it was confirmed that the part was not yet available. The contact stated that the…

Read full complaint

Takata Recall. The contact owns a 2012 GMC Sierra 1500. The contact received notification of NHTSA Campaign Number: 21V054000 (Air Bags) however, the part to do the recall repair was unavailable. The contact took the vehicle to the local dealer and it was confirmed that the part was not yet available. The contact stated that the manufacturer had exceeded a reasonable amount of time for the recall repair. The manufacturer was made aware of the issue. The contact had not experienced a failure. Vin tool confirms parts not available.

NHTSA ODI #11420062

320,000 miles · Jun 2, 2021
Air Bags

Takata Recall. The contact owns a 2012 GMC Sierra 1500. The contact received notification of NHTSA Campaign Number: 21V054000 (Air Bags) however, the part to do the recall repair was not yet available. The contact stated that the air bag warning light had been illuminated for two years. The contact contacted the dealer before re…

Read full complaint

Takata Recall. The contact owns a 2012 GMC Sierra 1500. The contact received notification of NHTSA Campaign Number: 21V054000 (Air Bags) however, the part to do the recall repair was not yet available. The contact stated that the air bag warning light had been illuminated for two years. The contact contacted the dealer before receiving the recall notification but was informed by the dealer that there was no air bag recall associated with the VIN. The manufacturer was made aware of the failure. The failure mileage was 320,000. VIN tool confirms parts not available.

NHTSA ODI #11419358

Mileage unknown · Apr 30, 2021
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2012 GMC SIERRA 1500. THE CONTACT RECEIVED NOTIFICATION NHTSA CAMPAIGN NUMBER: 21V054000 (AIR BAGS) HOWEVER, THE PART TO DO THE RECALL REPAIR WAS NOT YET AVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. MARK ALLEN BUICK GMC (6363…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2012 GMC SIERRA 1500. THE CONTACT RECEIVED NOTIFICATION NHTSA CAMPAIGN NUMBER: 21V054000 (AIR BAGS) HOWEVER, THE PART TO DO THE RECALL REPAIR WAS NOT YET AVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. MARK ALLEN BUICK GMC (6363 E OKLAHOMA PL # 66, TULSA, OK 74115(918) 770-4339) WAS CONTACTED AND CONFIRMED THAT THE PART WAS NOT YET AVAILABLE. THE CONTACT HAD NOT EXPERIENCED A FAILURE. THE MANUFACTURER WAS MADE AWARE OF THE ISSUE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #11414559

Mileage unknown · Apr 13, 2021
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2012 GMC SIERRA 1500. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 21V054000 (AIR BAGS) HOWEVER, THE PART TO DO THE RECALL REPAIR WAS UNAVAILABLE. A DEALER WAS NOT CONTACTED. THE CONTACT STATED THAT THE MANUFACTURER HAD EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAI…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2012 GMC SIERRA 1500. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 21V054000 (AIR BAGS) HOWEVER, THE PART TO DO THE RECALL REPAIR WAS UNAVAILABLE. A DEALER WAS NOT CONTACTED. THE CONTACT STATED THAT THE MANUFACTURER HAD EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE MANUFACTURER WAS NOT MADE AWARE OF THE ISSUE. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #11407957

111,000 miles · Feb 25, 2021
Air Bags

TL* THE CONTACT OWNS A 2012 GMC SIERRA 1500. THE CONTACT WAS STARTING UP THE VEHICLE WHEN THE AIR BAG WARNING LIGHT ILLUMINATED. THE CONTACT TOOK THE VEHICLE TO ABERNETHY CHEVROLET BUICK GMC (1445 E MAIN ST, LINCOLNTON, NC 28092) HOWEVER, THE DEALER COULD NOT REPLICATE THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE CONTACT RECEI…

Read full complaint

TL* THE CONTACT OWNS A 2012 GMC SIERRA 1500. THE CONTACT WAS STARTING UP THE VEHICLE WHEN THE AIR BAG WARNING LIGHT ILLUMINATED. THE CONTACT TOOK THE VEHICLE TO ABERNETHY CHEVROLET BUICK GMC (1445 E MAIN ST, LINCOLNTON, NC 28092) HOWEVER, THE DEALER COULD NOT REPLICATE THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 21V051000 (AIR BAGS) HOWEVER, THE PART TO DO THE RECALL REPAIR WAS NOT YET AVAILABLE. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE FAILURE MILEAGE WAS 110,000. VIN TOOL CONFIRMS PARTS NOT AVAILABLE. ## VIN PASSED ## GMC 2012 SIERRA ##

NHTSA ODI #11397890

150,000 miles · Jan 15, 2021
Air BagsElectrical System

LEFT SIDE IMPACT SENSOR LOSES CONNECTIVITY FROM WIRES SHORTING OUT IN DRIVERS HINGE AREA. SERVICE AIR BAG LIGHT COMES ON.

NHTSA ODI #11388294

219,000 miles · Nov 23, 2020
Air Bags

SERVICE AIRBAG LIGHT WILL NOT TURN OFF. WHILE DRIVING.

NHTSA ODI #11376022

60,000 miles · Feb 11, 2020
Air Bags

DASHBOARD IS CRACKING AROUND PASSENGER-SIDE AIRBAG. THE PLASTIC IS SHARP AND BRITTLE, AND I'M CONCERNED THAT SHARP SHARDS OF PLASTIC WOULD GO EVERYWHERE IF THE AIRBAG DEPLOYED. THIS IS AN EXTREMELY WELL-CARED FOR VEHICLE THAT COULD PASS FOR 'NEW CONDITION' OTHER THAN THIS DASHBOARD ISSUE.

NHTSA ODI #11308531

113,067 miles · Oct 28, 2019
Air Bags

TL AN INDEPENDENT MECHANIC CALLED ON BEHALF OF THE OWNER OF A 2012 GMC SIERRA 1500. WHILE DRIVING 30 MPH, THE FRONT AND REAR DRIVER SIDE CURTAIN AIR BAGS DEPLOYED ON THEIR OWN AND THE AIR BAG WARNING INDICATOR WAS ILLUMINATED. THERE WERE NO INJURIES. THE VEHICLE WAS TAKEN TO AN AUTO BODY SHOP TO HAVE THE AIR BAGS REPAIRED. THE V…

Read full complaint

TL AN INDEPENDENT MECHANIC CALLED ON BEHALF OF THE OWNER OF A 2012 GMC SIERRA 1500. WHILE DRIVING 30 MPH, THE FRONT AND REAR DRIVER SIDE CURTAIN AIR BAGS DEPLOYED ON THEIR OWN AND THE AIR BAG WARNING INDICATOR WAS ILLUMINATED. THERE WERE NO INJURIES. THE VEHICLE WAS TAKEN TO AN AUTO BODY SHOP TO HAVE THE AIR BAGS REPAIRED. THE VEHICLE WAS NOT DIAGNOSED OR REPAIRED. THE DEALER AND MANUFACTURER WERE NOT NOTIFIED. THE FAILURE MILEAGE WAS 113,067. *LN*JB

NHTSA ODI #11271552

Official recalls

3

21V051000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2012 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL originally sold, or ever registered, in the states of Alabama, California, Florida, Georgia, Hawaii, Louisiana, Mississippi, South Carolina, Texas, Puerto Rico, American Samoa, Guam, the Northern Mariana Islands (Saipan), and the U.S. Virgin Islands or "Zone A." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 22, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on May 11, 2021. Owners may contact Cadillac customer service at 1-800-458-8006; Chevrolet customer service at 1-800-222-1020; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328770.

21V054000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of AL, CA, FL, GA, HI, LA, MS, SC, TX, PR, AS, GU, the MP, and VI or "Zone A." Additionally GM is recalling certain 2011-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, Yukon XL and 2011-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AZ, AR, DE, DC, IL, IN, KS, KY, MD, MO, NE, NV, NJ, NM, NC, OH, OK, PA, TN, VA, and WV or "Zone B." Additionally, GM is recalling certain 2010-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL and 2010-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AK, CO, CT, ID, IA, ME, MA, MI, MN, MT, NH, NY, ND, OR, RI, SD, UT, VT, WA, WI, and WY or "Zone C." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 25, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed to 40 VIN owners on May 11, 2021. A second owner notification letter was mailed to all other owners on January 24, 2022. Owners may contact Chevrolet customer service at 1-800-222-1020; Cadillac customer service at 1-800-458-8006; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328800.

18V267000 · Equipment

Apr 26, 2018

General Motors LLC (GM) is recalling certain 2009-2014 Chevrolet Silverado HD and GMC Sierra HD, 2009 GMC Topkick 5000, 6000, 7000 and 8000 Series and Isuzu F Series, and 2009-2018 Chevrolet Express, and GMC Savana vehicles, equipped with certain Plastic-Handle Fire Extinguishers or Push Button 'Pindicator' Fire Extinguishers. These extinguishers may become clogged, preventing the extinguisher from discharging as expected or requiring excessive force to activate the extinguisher. Additionally, in certain models, the nozzle may detach from the valve assembly with enough force that it could cause injury and also render the product inoperable. For a full list of the affected fire extinguisher models visit: https://static.nhtsa.gov/odi/rcl/2017/RMISC-17E062-5427.pdf

Consequence & remedy

Consequence: In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.

Remedy: GM will notify owners, instructing them to contact Kidde to get a replacement fire extinguisher, free of charge. The recall began June 11, 2018. Owners may contact Chevrolet customer service at 1-800-222-1020, GMC customer service at 1-800-462-8782, and Isuzu customer service at 1-866-441-9638. GM's number for this recall is 18146.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

DP22005 · Pedestrian Alert Sounds

Opened Jan 27, 2023 · Closed Aug 7, 2023

Status: closed (inferred from source dates) · Electrical System:propulsion System

NHTSA received a petition on or about July 18, 2022, requesting that Federal Motor Vehicle Safety Standard (FMVSS) 141 be applied to all electric and hybrid vehicles operating in the United States. The petition can be reviewed at NHTSA.gov under ODI Number 11486072. FMVSS 141 establishes performance requirements for pedestrian alert sounds for motor vehicles. The standard applies to hybrid and electric vehicles that have a gross vehicle weight rating of 4,536 KG or less or are defined as low-speed vehicles. The standard became fully applicable to all such vehicles manufactured on or after March 1, 2021.On January 27, 2023, NHTSA opened Defect Petition (DP) 22-005 to evaluate the subject matter described in the petition. On June 24, 2023 and as supplemented on June 25, 2023, the petitioner notified NHTSA he was withdrawing his petition. The petitioner indicated that, based on his review of data, there is no justification for asserting potential benefits that could be derived from actions sought by my petition. Based on the petitioner's withdrawal, DP22-005 is closed. Closure of this DP does not represent a determination by NHTSA regarding the subject matter of the petition.

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.