← New search

1995 Ford Windstar

Owner reports · Recalls · Investigations

More warning signs than most Windstar years

Owner complaints for the 1995 Ford Windstar are substantially higher than the model-year median of 192.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 223 of 3,326 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Engine And Engine Cooling. Review the 1,610 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 875 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 484 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

134 crash reports49 fire reports72 injury reports

Suspension complaints

145 reports
Clear category filter
Mileage unknown · Sep 10, 2001
Power TrainSuspension

VEHICLE WOULD HAVE SEVERE SHAKING IN FRONT WHEELS WHEN SPEEDOMETER REACHES 50MPH AND ABOVE. CAN MAINTAIN CONTROL OF VEHICLE WHEN VIBRATING. PROBLEM IS MOST NOTICEABLE WHEN VEHICLE IS LOADED DOWN OR GOING DOWN HILL. BEEN TO DEALERSHIP, AND INFORMED PROBLEM WAS NORMAL.*AK

NHTSA ODI #896143

Mileage unknown · Sep 10, 2001
Suspension

FRONT RIGHT WHEEL BEARINGS WERE CAUSING A "TICKING" NOISE DURING OPERATION OF VEHICLE. DEALERSHIP REPLACED WHEEL BEARINGS THREE TIMES, AND HAS NOT BEEN ABLE TO REMEDY PROBLEM. PLEASE PROVIDE ANY ADDITIONAL INFORMATION / ATTACHMENTS.*AK

NHTSA ODI #896138

Mileage unknown · Aug 23, 2001
Engine And Engine CoolingSuspension

NO SUMMARY LISTED FOR ABOV EVEHICLE. *AK

NHTSA ODI #750967

Mileage unknown · Aug 19, 2001
Electrical SystemEngine And Engine CoolingPower Train

I HAVE HAD A CONTINUING STREAM OF ENDLESS REPAIRS TO THIS FORD WINDSTAR. STARING WITH THE WATER PUMP ONE WEEK AFTER PURCHASE; THEN THE LEFT FRONT SPRING AND STRUT COLLASPED; NEXT THE ABS SYSTEM ALMOST COST ME MY LIFE BY FAILING ON A DOWNGRADE INTO AN INTERSECTION; A COMPOENT OF THE FUEL INJECTION SYSTEM IN THE MAIN COMPUTER FAI…

Read full complaint

I HAVE HAD A CONTINUING STREAM OF ENDLESS REPAIRS TO THIS FORD WINDSTAR. STARING WITH THE WATER PUMP ONE WEEK AFTER PURCHASE; THEN THE LEFT FRONT SPRING AND STRUT COLLASPED; NEXT THE ABS SYSTEM ALMOST COST ME MY LIFE BY FAILING ON A DOWNGRADE INTO AN INTERSECTION; A COMPOENT OF THE FUEL INJECTION SYSTEM IN THE MAIN COMPUTER FAILED; THE REAR MASTER CYLINDER ON THE BRAKES WAS LEAKING; THE TRANSMISSION HAS NEVER SHIFTED CORRECTLY ALMOST GIVING PASSENGERS WHIPLASH; THE REAR POWER DOOR LOCK ON THE TAILGATE HAS JUST NEVER WORKED FORM DAY ONE; I DID RECEIVE A RECALL FOR THE HOOD AND THAT WAS REPLACED; NOW THE POWER WINDOWS OPERATE WITHOUT THE KEY IN THE IGNITION, BUT THE DOOR LOCKS DO NOT WORK AND THE VEHICLE IS TOTALLY DIABLED, IT WILL NOT START OR EVEN TRY TO TURN OVER. I AM JUST A NURSE NOT A MILLIONAIRE, I HAVE PAID ALMOST $5,000.00 IN REPAIRS INTO THIS VEHICLE IN THE 2 1/2 YEARS I HAVE OWNED IT. AND NOW IT IS DEAD, LEAVING ME WITH NO TRANSPORTATION TO WORK, MY ONLY SOURCE OF INCOME. PLEASE HELP.

NHTSA ODI #750761

Mileage unknown · Jun 27, 2001
Suspension

CONSUMER WAS INSIDE THE HOUSE AND HEARD A LOUD CRASH SOUND. CONUSMER WAS UNAWARE THAT IT WAS THE VEHICLE. FRONT END WAS MOUNTED ON WHEELS. DEALER STATED SPRINGS WERE CORRODED. CONSUMER HIRED A INVESTIGATOR TO INSPECT VEHICLE FURTHER. SPRINGS COLLAPSED BECAUSE COATING FOR CORROSION PREMATURELY WORE OFF. COST TO REPAIR…

Read full complaint

CONSUMER WAS INSIDE THE HOUSE AND HEARD A LOUD CRASH SOUND. CONUSMER WAS UNAWARE THAT IT WAS THE VEHICLE. FRONT END WAS MOUNTED ON WHEELS. DEALER STATED SPRINGS WERE CORRODED. CONSUMER HIRED A INVESTIGATOR TO INSPECT VEHICLE FURTHER. SPRINGS COLLAPSED BECAUSE COATING FOR CORROSION PREMATURELY WORE OFF. COST TO REPAIR WAS $952. *AK A SUSPENSION SPRING FAILED AND PUNCTURED THE FRONT TIRE, BOTH SPRINGS WERE REPLACED ALONG WITH THE TIRES, THE POOR ADHESION OF THE BLACK COATING MATERIAL IS APPARENTLY A DESIGN PROBLEM IN THE SPRING, IT IS POSSIBLE THE STRESSES AND BENDING MOMENTS IN THE BOTTOM OF THE SPRING ARE GREATER AND THEREFORE CAUSED THE BOND BETWEEN THE COATING AND THE SPRING TO SLOWLY DETERIORATE, THROUGH THE CONTINUOUS LOADING OF THE SPRING AND SLOW DETERIORATION OF THE BOND OF THE COATING, THE COATING STARTED TO FLAKE OFF EXPOSING THE BARE STEEL. *SLC

NHTSA ODI #891469

Mileage unknown · Jun 11, 2001
Engine And Engine CoolingSuspension

LEAKED QUITE A BIT OF ANTIFREEZE...HAD TO REPLACE TIMING COVER GASKET. ALSO MORE RECENTLY, A FRONT TIRE BLEW DUE TO RUSTED FRONT SPRINGS AND STRUTS WHICH HAD TO BE REPLACED. *AK

NHTSA ODI #746654

Mileage unknown · Jun 8, 2001
Suspension

VEHICLE WAS PARKED IN GARAGE, CONSUMER HEARD A LOUD NOISE, WENT OVER TO VEHICLE AND SAW THAT FRONT RIGHT OF VEHICLE HAD DROPPED. FRONT PASSENGER'S SIDE COIL SPRING BROKE. NO PRIOR PROBLEMS ON THIS ISSUE. *AK

NHTSA ODI #890005

Mileage unknown · Jun 4, 2001
Suspension

FRONT SUSPENSION SPRING HAD SNAPPED WHILE PULLING INTO DRIVEWAY. CONTACTED MECHANIC, AND INFORMED CONSUMER NOT TO DRIVE VEHICLE, BUT HAVE IT TOWED IN FOR REPAIRS. *AK

NHTSA ODI #889734

Mileage unknown · Jun 3, 2001
Suspension

NO SUMMARY LISTED FOR ABOVE VEHICLE. *AK

NHTSA ODI #746346

Mileage unknown · May 30, 2001
Suspension

WHILE TRAVELING AND WITHOUT ANY INDICATION FRONT LEFT SPRING HAD BROKEN, CAUSING FRONT TIRE TO GO FLAT. PLEASE PROVIDE FURTHER INFORMATION. *AK

NHTSA ODI #889385

Official recalls

6

09V399000 · Vehicle Speed Control

Oct 13, 2009

FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.

Remedy: FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

02V101000 · Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

Apr 4, 2002

ON CERTAIN MINIVANS ORIGINALLY SOLD IN OR CURRENTLY REGISTERED IN THE STATES OF CONNECTICUT, DELAWARE, ILLINOIS, INDIANA, IOWA, MAINE, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, MISSOURI, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OHIO, PENNSYLVANIA, RHODE ISLAND, VERMONT, WEST VIRGINIA, WISCONSIN, AND THE DISTRICT OF COLUMBIA. DURING ASSEMBLY, SOME BRAKE LINES WERE INSTALLED IN A TWISTED POSITION, CAUSING CONTACT WITH THE DASH PANEL INSULATOR ABOVE THE CATALYTIC CONVERTER. THIS CONTACT COULD ABRADE THE BRAKE LINE CORROSION PROTECTION, CONSEQUENTLY, SALT OR WATER ABSORBED IN THE DASH PANEL INSULATOR WOULD PROMOTE CORROSION. THIS CORROSION COULD ULTIMATELY LEAD TO A LEAK IN THE BRAKE LINE.

Consequence & remedy

Consequence: LEAKAGE OF BRAKE FLUID WILL RESULT IN BRAKE LIGHT ACTIVATION. EXTENDED STOPPING DISTANCE COULD ALSO RESULT, INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL INSPECT THE BRAKE LINE FOR CORROSION AND CLEARANCE CONDITIONS. A BRAKE LINE THAT IS NOT CORRODED WILL BE REPOSITIONED. A BRAKE LINE THAT IS CORRODED OR LEAKING WILL BE REPLACED WITH A NYLON COATED BRAKE LINE AND SECURED USING THREE RETAINING CLIPS TO ASSURE CLEARANCE FROM THE INSULATOR. OWNER NOTIFICATION BEGAN MAY 10, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332.

99V309000 · Fuel System, Gasoline:storage:tank Assembly

Nov 2, 1999

VEHICLE DESCRIPTION: MINIVANS WHICH WERE ORIGINALLY SOLD OR CURRENTLY REGISTERED IN THE FOLLOWING HOT WEATHER STATES: ALABAMA, ARIZONA, ARKANSAS, CALIFORNIA (10 SOUTHERN COUNTIES), FLORIDA, GEORGIA, HAWAII, LOUISIANA, MISSISSIPPI, NEVADA (CLARK COUNTY ONLY), OKLAHOMA, SOUTH CAROLINA AND TEXAS, CAN DEVELOP CRACKS IN THE FUEL TANK IN THE FORWARD STRAP AREA OF THE STANDARD 20 GALLON TANK DUE TO A COMBINATION OF FACTORS THAT ARE PRESENT IN CERTAIN VERY HOT AREAS OF THE COUNTRY.

Consequence & remedy

Consequence: THESE CRACKS COULD RESULT IN FUEL LEAKAGE IF THEY PROPAGATE THROUGH THE WALL OF THE TANK.

Remedy: DEALERS WILL INSTALL A BRACE ASSEMBLY AT THE STRAP BOLT HOLE LOCATION AND REPLACE THE TANK STRAP WITH A REVISED, LONGER STRAP. DEALERS WILL ALSO INSPECT THE TANKS FOR LEAKS. IF A LEAK EXISTS AND IS THE RESULT OF A CRACK IN THE FUEL TANK, THE TANK WILL BE REPLACED IN ADDITION TO THE INSTALLATION OF A SPACER AND LONGER STRAP.

97V180000 · Structure:body:hood

Oct 20, 1997

VEHICLE DESCRIPTION: PASSENGER VEHICLES AND MINI VANS. TEARING OF THE BOND BETWEEN THE INNER AND OUTER HOOD PANELS DURING MINOR FRONT END COLLISIONS CAN RESULT IN A GAP AT THE LEADING EDGE OF THE HOOD. AIR FORCED BETWEEN THE INNER AND OUTER PANELS CAN PRODUCE ENOUGH PRESSURE TO FORCE THE OUTER PANEL UPWARD.

Consequence & remedy

Consequence: THIS CONDITION CAN RESULT IN TOTAL SEPARATION OF THE OUTER HOOD PANEL.

Remedy: DEALERS WILL INSPECT THE HOOD AREA FOR ANY DAMAGE ALONG THE LEADING EDGE OF THE HOOD. IF THERE IS ANY EVIDENCE OF BOND SEPARATION, THE HOOD WILL BE REPLACED. IF THERE IS NO EVIDENCE OF BOND SEPARATION, ADDITIONAL ADHESIVE WILL BE APPLIED BETWEEN THE INNER AND OUTER HOOD PANELS.

94V222000 · Electrical System:wiring:front Underhood

Nov 4, 1994

THE WIRING HARNESS INSULATION CAN ABRADE ON A BRACE THAT RUNS FROM THE INSTRUMENT PANEL TO THE COWL.

Consequence & remedy

Consequence: THIS CONDITION CAN RESULT IN AN ELECTRICAL SHORT AND POSSIBLY A VEHICLE FIRE.

Remedy: DEALERS WILL INSTALL A SHIELD ON THE INSTRUMENT PANEL TO COWL BRACE, AND INSTALLATION OF A PIECE OF CONVOLUTE WRAP MATERIAL ON ONE OF THE ADJACENT HARNESSES.

94V223000 · Electrical System:alternator/generator/regulator

Nov 4, 1994

THE ALTERNATOR OUTPUT WIRE WAS NOT CONNECTED TIGHTLY TO THE POWER DISTRIBUTION BOX.

Consequence & remedy

Consequence: THIS CAN RESULT IN OVERHEATING OF THE CONNECTION AND A POSSIBLE VEHICLE FIRE.

Remedy: DEALERS WILL INSPECT AND TIGHTEN THE CONNECTION. VEHICLES WITH VISIBLE DAMAGE TO THE PLASTIC POWER DISTRIBUTION BOX HOUSING WILL HAVE THE THE UNDERHOOD HARNESS, INCLUDING THE POWER DISTRIBUTION BOX, REPLACED.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

14

EA08021 · Engine Compartment Fires

Opened Sep 17, 2008 · Closed Oct 14, 2009

Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Service Brakes, Hydraulic; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module ; Vehicle Speed Control; Vehicle Speed Control:cruise Control

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Additional source detail variants (7)

Electrical System

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Electrical System:wiring

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Service Brakes, Hydraulic

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Vehicle Speed Control:cruise Control

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Vehicle Speed Control

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

PE08035 · Engine Compartment Fires

Opened May 13, 2008 · Closed Sep 17, 2008

Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Vehicle Speed Control

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

Additional source detail variants (3)

Electrical System

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

Electrical System:wiring

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

Vehicle Speed Control

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

RQ04003 · Hydraulic Brake Line Failure

Opened May 27, 2004 · Closed Oct 7, 2004

Status: closed (inferred from source dates) · Service Brakes, Hydraulic; Service Brakes, Hydraulic:fluid; Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Additional source detail variants (3)

Service Brakes, Hydraulic:fluid

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Service Brakes, Hydraulic

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

RQ02011 · Fuel Tank Fatigue Cracking

Opened Aug 29, 2002 · Closed Mar 14, 2003

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

SEE ATTACHED REPORT.

EA00027 · Suspension Coil Spring Breakage

Opened Dec 8, 2000 · Closed Jul 31, 2001

Status: closed (inferred from source dates) · Suspension

There is no summary currently available

Additional source detail variants (2)

Suspension

There is no summary currently available

Suspension

There is no summary currently available

PE00024 · Suspension Coil Spring Breakage

Opened Jun 23, 2000 · Closed Dec 8, 2000

Status: closed (inferred from source dates) · Suspension

There is no summary currently available

EA99020 · Fuel Tank Cracks

Opened Jul 26, 1999 · Closed Dec 16, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline

There is no summary currently available

PE99025 · Fuel Tank Cracks

Opened Apr 15, 1999 · Closed Jul 26, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline

There is no summary currently available

PE98056 · Rear Axle Trailing Arm

Opened Oct 28, 1998 · Closed Feb 24, 1999

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

DP98004 · Automatic Transmission Failure

Opened May 18, 1998 · Closed Jul 2, 1998

Status: closed (inferred from source dates) · Power Train

There is no summary currently available

EA97018 · Outer Hood Panel Detachment

Opened Sep 30, 1997 · Closed Oct 22, 1997

Status: closed (inferred from source dates) · Structure

There is no summary currently available

PE97011 · Outer Hood Panel Detachment

Opened Mar 13, 1997 · Closed Sep 30, 1997

Status: closed (inferred from source dates) · Structure

THE OFFICE OF DEFECTS INVESTIGATION HAS RECEIVED 6 REPORTS INDICATING THE OUTER HOOD PANEL SEPARATED FROM THE VEHICLES AS THEY WERE BEING DRIVEN.FORD HAS PROVIDE 39 ADDITIONAL REPORTS THAT ARE CONSISTENT WITH ODI REPORTS.FORD INDICATES THAT THE LIKELY CAUSE IS PRIOR COLLISION DAMAGE.THIS INVESTIGATION IS BEING UPGRADED TO FURTHER STUDY THIS ISSUE.

EA96026 · Brake Pedal Fade/extended Stop Distance

Opened Oct 31, 1996 · Closed Feb 18, 2000

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE96042 · Brake Pedal Fade/extended Stopping

Opened Jun 13, 1996 · Closed Oct 31, 1996

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

ODI HAS RECEIVED SIXTY-EIGHT (68) CONSUMER REPORTS OF ALLEGED FAILURES OR MALFUNCTIONS IN THE BRAKE SYSTEM ON CERTAIN 1995 AND 1996 FORD WINDSTARS, WHICH RESULTED IN BRAKE PEDAL FADE AND IN EXTENDED STOPPING DISTANCES DURING BRAKINGTHESE ALLEGED FAILURES OR MALFUNCTIONS ARE REPORTED TO HAVE CAUSED TWELVE (12) ACCIDENTS THAT RESULTED FROM VEHICLE LOSS OF BRAKING.THE CONPLAINANTS REPORT THAT THE LOSS OF BRAKING OCCURRED DURINGBRAKING SITUATIONS ON DRY ROADS AS WELL AS ON WET OR SLIPPERY ROADS.IN RESPONSE TO ODI'S INFORMATION REQUES (IR) CONCERNING THE LONG STOPPING DISTANCE COMPLAINTS ON THE 1995 WINDSTAR, FORD REPORTED RECEIVING 259 REPORT (FIELD REPORTS, OWNER COMPLAINTS, AND SUBROGATION CLAIMS) OF LONG STOPPING DISTANCE ON THE 1995 FORD WINDSTAR, ALONG WITH 64 REPORTS OF ACCIDENTS.IN ADDITION, FORD REPORTED RECEIVING SOME 64,000 WARRANTY CLAIMS THAT COULD RELATE TO THE ALLEGED DEFECT OF LONG STOPPING DISTANCE PERFORMANCE ON THE SUBJECT VEHICLES.SINCE APRELIMINARY EVALUATION WAS OPENED, ODI HAS RECEIVED ADDITIONAL COMPLAINTS OF THE ALLEGED FAILURE ON THE 1996 MODELS, WHICH WERE NOT INCLUDED INITIALLY IN THIS INVESTIGATION.ODI BELIEVES THAT AN ENGINEERING ANALYSIS ON THE 1995 AND 1996 FORD WINDSTAR VEHICES IN WARRANTED TO DETERMINE THE SCOPE OF THE PROBLEM.