NHTSA owner reports · September 18, 2026 snapshot.
Power Train complaints
875 reportsClear category filter157,231 miles · Mar 11, 2006
Power Train
FORD WINDSTAR 1995-TRANSMISSION HAD COMPLETE FAILURE. HIT GAS AND WAS UNABLE TO GO IN ANY GEAR. TRANSMISSION REPAIR FACILITY SAID FAILURE WAS CAUSED BY ALUMINUM PISTON, REPLACED WITH STEEL. ALSO FACILITY REPORTED FORD SUGGESTS OVERFILLING TRANSMISSION WITH FLUID SO SUFFICIENT FLUID IS AVAILABLE WHEN TURNING CORNERS. TOTAL CO…
Read full complaint
FORD WINDSTAR 1995-TRANSMISSION HAD COMPLETE FAILURE. HIT GAS AND WAS UNABLE TO GO IN ANY GEAR. TRANSMISSION REPAIR FACILITY SAID FAILURE WAS CAUSED BY ALUMINUM PISTON, REPLACED WITH STEEL. ALSO FACILITY REPORTED FORD SUGGESTS OVERFILLING TRANSMISSION WITH FLUID SO SUFFICIENT FLUID IS AVAILABLE WHEN TURNING CORNERS. TOTAL COST OF REPAIR WAS OVER $2000. *NM
NHTSA ODI #10152456
130,000 miles · Jan 27, 2006
Power Train
TRANSMISSION WAS OVERHAULED BY A FORD DEALER IN 1997 WITH A $400 DEDUCTIBLE. TRANSMISSION FAILED AGAIN IN 2002 AND WAS REBUILT. THE VAN IS CURRENTLY IN THE SHOP AGAIN FOR MORE TRANSMISSION WORK AT THE COST OF $1995. THE TRANSMISSION FAILED AGAIN WHILE DRIVING. THIS CREATED A HAZARDOUS CONDITION FOR MY CHILDREN AND I. THE COST OF…
Read full complaint
TRANSMISSION WAS OVERHAULED BY A FORD DEALER IN 1997 WITH A $400 DEDUCTIBLE. TRANSMISSION FAILED AGAIN IN 2002 AND WAS REBUILT. THE VAN IS CURRENTLY IN THE SHOP AGAIN FOR MORE TRANSMISSION WORK AT THE COST OF $1995. THE TRANSMISSION FAILED AGAIN WHILE DRIVING. THIS CREATED A HAZARDOUS CONDITION FOR MY CHILDREN AND I. THE COST OF REPAIRS THIS TIME WILL EXCEED $2000 AT AN INDEPENDENT TRANSMISSION SHOP. FORD IS AWARE OF THIS PROBLEM AND HAS ISSUED A TCP PREVIOUSLY. I PUSH FOR A RECALL AND FOR FORD TO OFFSET THE COST OF SEVERAL TRANSMISSION OVERHAULS.*AK
NHTSA ODI #10148812
79,500 miles · Sep 7, 2005
Power Train
THE AUTOMATIC TRANSMISSION ON THE VEHICLE NEEDS TO BE REBUILT/REPLACED. AT 80,000 MILES. I DO NOT TOW WITH THE VEHICLE NOR DID I ABUSE IT. I AM THE ORIGINAL OWNER. TRANSMISSION REPAIR SHOP FOUND BITS OF METAL IN FLUID. *NM
NHTSA ODI #10135563
Mileage unknown · Aug 5, 2005
Engine And Engine CoolingFuel System, GasolinePower Train
DT: THE CONTACT OWNED A 1995 FORD WINDSTAR. THE CONTACT PURCHASED THE VEHICLE ON JUNE 3, 2005 AND THE ODOMETER READ 59,000 MILES. CONTACT RAN A CAR FAX REPORT, AND IN THE YEAR 2000 THE REPORT WAS SHOWING 100,300 MILES ON THE VEHICLE. ALSO, THE VEHICLE WAS NOT DRIVABLE BECAUSE THE TRANSMISSION, HEAD GASKET, AND FUEL INJECTI…
Read full complaint
DT: THE CONTACT OWNED A 1995 FORD WINDSTAR. THE CONTACT PURCHASED THE VEHICLE ON JUNE 3, 2005 AND THE ODOMETER READ 59,000 MILES. CONTACT RAN A CAR FAX REPORT, AND IN THE YEAR 2000 THE REPORT WAS SHOWING 100,300 MILES ON THE VEHICLE. ALSO, THE VEHICLE WAS NOT DRIVABLE BECAUSE THE TRANSMISSION, HEAD GASKET, AND FUEL INJECTION BROKE. SHE SPOKE WITH THE DEALERSHIP, AND STATED WHEN THEY SOLD THE VAN FOR SOMEONE ELSE THEY WOULD TRY TO GET CONTACT MONEY BACK. *AK
NHTSA ODI #10131700
Mileage unknown · Mar 18, 2005
Engine And Engine CoolingPower Train
DEFECTIVE 1995 FORD WINDSTAR WITH RECURRENT MECHANICAL MALFUNCTION. *BF THE TRANSMISSION WAS REPLACED SOON AFTER THE VEHICLE WAS PURCHASED. THE CONSUMER EXPERIENCED AN ENGINE KNOCK FOR THE 3RD TIME WHICH WAS DUE TO A MECHANICAL MALFUNCTION. *JB
NHTSA ODI #10115594
180,000 miles · Nov 22, 2004
Power TrainFire
CAR ENGINE WAS SKIPPING WHILE DRIVING DOWN THE ROAD AT MID SPEEDS, AUTO SHOP SAID IT WAS EITHER THE TORQUE CONVERTER STARTING TO GO BAD OR THE TRANSMISSION HAD A SHORT IN THE OVERDRIVE SWITCH. NEXT NIGHT AFTER DRIVING APPROX 30 MILES, PARKED CAR IN DRIVEWAY, 20 MINUTES LATER, WHOLE FRONT END OF CAR WAS ENGULFED IN FLAMES. CAR W…
Read full complaint
CAR ENGINE WAS SKIPPING WHILE DRIVING DOWN THE ROAD AT MID SPEEDS, AUTO SHOP SAID IT WAS EITHER THE TORQUE CONVERTER STARTING TO GO BAD OR THE TRANSMISSION HAD A SHORT IN THE OVERDRIVE SWITCH. NEXT NIGHT AFTER DRIVING APPROX 30 MILES, PARKED CAR IN DRIVEWAY, 20 MINUTES LATER, WHOLE FRONT END OF CAR WAS ENGULFED IN FLAMES. CAR WAS TOTALED BY INSURANCE COMPANY. *JB
NHTSA ODI #10100363
Mileage unknown · Sep 20, 2004
EquipmentPower TrainVisibility
ENGINE HAS BEEN SPUTTERING, FLASHING OVERDRIVE LIGHT KEEPS COMING ON. REAR PASSENGER FRONT AND REAR WINDOWS WON'T OPEN, RADIO CONSOLE STARTED TO GET REAL HOT AND THEN WENT OUT. ENGINE CONTINUES TO SPUTTER AS THOUGH ITS SKIPPING A GEAR, AND OVERDRIVE LIGHT CONSTANTLY BLINKING.*AK
NHTSA ODI #10091308
78,000 miles · Jul 7, 2004
Electrical SystemEngine And Engine CoolingInterior LightingCrashInjury
I ASKED THE SELLER AT FORD TO COMPLETELY SERVICE THE VAN BEFORE I WOULD BUY IT. HE SAID HIS MECHANIC WOULD. I CHECKED THE VAN OUT TWO WEEKS LATER, LOW ON OIL, NO BRAKE FLUID, TRANS FLUID VERY LOW, NO WATER HARDLY AT ALL IN RECEIVER, THEN THE STARTER WENT OUT, REPLACED IT NO GOOD, REPLACED SWITCH, NO GOOD, BRAKES GONE OUT, CAN'T …
Read full complaint
I ASKED THE SELLER AT FORD TO COMPLETELY SERVICE THE VAN BEFORE I WOULD BUY IT. HE SAID HIS MECHANIC WOULD. I CHECKED THE VAN OUT TWO WEEKS LATER, LOW ON OIL, NO BRAKE FLUID, TRANS FLUID VERY LOW, NO WATER HARDLY AT ALL IN RECEIVER, THEN THE STARTER WENT OUT, REPLACED IT NO GOOD, REPLACED SWITCH, NO GOOD, BRAKES GONE OUT, CAN'T KEEP FLUID IN SYSTEMS, ENGINE LIGHT CAME ON, EMISSION PROBLEMS, MECHANIC STALLS FOR THE HOUR AMOUNT, AND STILL CAN'T FIX/TEST II CODE. INSIDE LIGHTS DIM WHEN EXTRA. LIGHTS COME ON. IT'S A [XXX] PIECE OF JUNK AND THEY SOLD US A LEMON. I PAID OVER $4,000.00 CASH FOR IT, AND ALL THEY WANTED TO SO WAS SELL IT FOR MONEY. WHAT CAN I DO? IT HAS 72,000 ETC MILE AND NOW HAS 82,000. WE ARE BOTH DISABLED WITH TWO KIDS. WE HAVE BEEN SCREWED. I CAN GET THE FORD INFO ON THE FORD WINDSTAR 95 3.8 IT RATTLES, WATER RUNS OUT OF THE EXHAUST PIPE AND THE CONVERTER. I WANT TO SUE THEM, I CALLED THEM AND THEY SAID THE HELL WITH YOU, YOU BOUGHT IT AS IT WAS. FORD PRODUCTS ARE THE WORST AUTO'S ON THE MARKET. WE WANT REVENGE AND ALL OUR MONEY BACK NOW. [XXX]. WHAT IS NEXT A HEAD GASKET? I HEARD THAT COST OVER $1,600.00 TO FIX. AND THERE ARE ALOT OF THEM GOING OUT. FORD NEEDS TO STAND BEHIND IT'S PRODUCTS OR GET OUT OF THE BUSINESS. I HAVE HAD MY KIDS TOSSED TO THE DASH WHEN I STEP ON THE BRAKES BEFORE WE EVEN GET OUT OF OUR DRIVE WAY. WE WEAR SEATBELTS, I WOULDN'T DARE RIDE IN IT. IT IS A DEATH TRAP TO ME.*AK INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6). *TR
NHTSA ODI #10080551
Mileage unknown · Jun 23, 2004
Engine And Engine CoolingPower TrainService Brakes, Hydraulic
PROBLEMS WITH HEAD GASKETS, TRANSMISSION, AND FAULTY BRAKES ON 1995 FORD WINDSTAR.*MR *JB
NHTSA ODI #10079786
Mileage unknown · Jun 23, 2004
Power Train
MY 1995 FORD WINDSTAR DIED OUT ONE DAY WHILE PARKING AT A STORE. IT STARTED UP AGAIN AND I IGNORED IT. A MONTH LATER IT MADE A STRANGE NOISE SO I HAD IT LOOKED AT. I WAS TOLD A PISTON WENT OUT IN MY ENGINE AND I NEEDED A NEW ENGINE. I REPLACED IT AND NOW IT COSTANTLLY DIES OUT. I HAD REPLACED MANY PARTS SUCH AS THE IDLE AIR…
Read full complaint
MY 1995 FORD WINDSTAR DIED OUT ONE DAY WHILE PARKING AT A STORE. IT STARTED UP AGAIN AND I IGNORED IT. A MONTH LATER IT MADE A STRANGE NOISE SO I HAD IT LOOKED AT. I WAS TOLD A PISTON WENT OUT IN MY ENGINE AND I NEEDED A NEW ENGINE. I REPLACED IT AND NOW IT COSTANTLLY DIES OUT. I HAD REPLACED MANY PARTS SUCH AS THE IDLE AIR CONTROL MOTOR, IDLE SPEED CONTROL SENSOR,MASS AIR FLOW SENSOR, AND NOW I AM IN THE PROCESS OF REPLACING THE POWERTRAIN COMPUTER MODULE. *AK
NHTSA ODI #10078652
Official recalls
6Oct 13, 2009
FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.
Remedy: FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Apr 4, 2002
ON CERTAIN MINIVANS ORIGINALLY SOLD IN OR CURRENTLY REGISTERED IN THE STATES OF CONNECTICUT, DELAWARE, ILLINOIS, INDIANA, IOWA, MAINE, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, MISSOURI, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OHIO, PENNSYLVANIA, RHODE ISLAND, VERMONT, WEST VIRGINIA, WISCONSIN, AND THE DISTRICT OF COLUMBIA. DURING ASSEMBLY, SOME BRAKE LINES WERE INSTALLED IN A TWISTED POSITION, CAUSING CONTACT WITH THE DASH PANEL INSULATOR ABOVE THE CATALYTIC CONVERTER. THIS CONTACT COULD ABRADE THE BRAKE LINE CORROSION PROTECTION, CONSEQUENTLY, SALT OR WATER ABSORBED IN THE DASH PANEL INSULATOR WOULD PROMOTE CORROSION. THIS CORROSION COULD ULTIMATELY LEAD TO A LEAK IN THE BRAKE LINE.
Consequence & remedy
Consequence: LEAKAGE OF BRAKE FLUID WILL RESULT IN BRAKE LIGHT ACTIVATION. EXTENDED STOPPING DISTANCE COULD ALSO RESULT, INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL INSPECT THE BRAKE LINE FOR CORROSION AND CLEARANCE CONDITIONS. A BRAKE LINE THAT IS NOT CORRODED WILL BE REPOSITIONED. A BRAKE LINE THAT IS CORRODED OR LEAKING WILL BE REPLACED WITH A NYLON COATED BRAKE LINE AND SECURED USING THREE RETAINING CLIPS TO ASSURE CLEARANCE FROM THE INSULATOR. OWNER NOTIFICATION BEGAN MAY 10, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332.
Nov 2, 1999
VEHICLE DESCRIPTION: MINIVANS WHICH WERE ORIGINALLY SOLD OR CURRENTLY REGISTERED IN THE FOLLOWING HOT WEATHER STATES: ALABAMA, ARIZONA, ARKANSAS, CALIFORNIA (10 SOUTHERN COUNTIES), FLORIDA, GEORGIA, HAWAII, LOUISIANA, MISSISSIPPI, NEVADA (CLARK COUNTY ONLY), OKLAHOMA, SOUTH CAROLINA AND TEXAS, CAN DEVELOP CRACKS IN THE FUEL TANK IN THE FORWARD STRAP AREA OF THE STANDARD 20 GALLON TANK DUE TO A COMBINATION OF FACTORS THAT ARE PRESENT IN CERTAIN VERY HOT AREAS OF THE COUNTRY.
Consequence & remedy
Consequence: THESE CRACKS COULD RESULT IN FUEL LEAKAGE IF THEY PROPAGATE THROUGH THE WALL OF THE TANK.
Remedy: DEALERS WILL INSTALL A BRACE ASSEMBLY AT THE STRAP BOLT HOLE LOCATION AND REPLACE THE TANK STRAP WITH A REVISED, LONGER STRAP. DEALERS WILL ALSO INSPECT THE TANKS FOR LEAKS. IF A LEAK EXISTS AND IS THE RESULT OF A CRACK IN THE FUEL TANK, THE TANK WILL BE REPLACED IN ADDITION TO THE INSTALLATION OF A SPACER AND LONGER STRAP.
Oct 20, 1997
VEHICLE DESCRIPTION: PASSENGER VEHICLES AND MINI VANS. TEARING OF THE BOND BETWEEN THE INNER AND OUTER HOOD PANELS DURING MINOR FRONT END COLLISIONS CAN RESULT IN A GAP AT THE LEADING EDGE OF THE HOOD. AIR FORCED BETWEEN THE INNER AND OUTER PANELS CAN PRODUCE ENOUGH PRESSURE TO FORCE THE OUTER PANEL UPWARD.
Consequence & remedy
Consequence: THIS CONDITION CAN RESULT IN TOTAL SEPARATION OF THE OUTER HOOD PANEL.
Remedy: DEALERS WILL INSPECT THE HOOD AREA FOR ANY DAMAGE ALONG THE LEADING EDGE OF THE HOOD. IF THERE IS ANY EVIDENCE OF BOND SEPARATION, THE HOOD WILL BE REPLACED. IF THERE IS NO EVIDENCE OF BOND SEPARATION, ADDITIONAL ADHESIVE WILL BE APPLIED BETWEEN THE INNER AND OUTER HOOD PANELS.
Nov 4, 1994
THE WIRING HARNESS INSULATION CAN ABRADE ON A BRACE THAT RUNS FROM THE INSTRUMENT PANEL TO THE COWL.
Consequence & remedy
Consequence: THIS CONDITION CAN RESULT IN AN ELECTRICAL SHORT AND POSSIBLY A VEHICLE FIRE.
Remedy: DEALERS WILL INSTALL A SHIELD ON THE INSTRUMENT PANEL TO COWL BRACE, AND INSTALLATION OF A PIECE OF CONVOLUTE WRAP MATERIAL ON ONE OF THE ADJACENT HARNESSES.
Nov 4, 1994
THE ALTERNATOR OUTPUT WIRE WAS NOT CONNECTED TIGHTLY TO THE POWER DISTRIBUTION BOX.
Consequence & remedy
Consequence: THIS CAN RESULT IN OVERHEATING OF THE CONNECTION AND A POSSIBLE VEHICLE FIRE.
Remedy: DEALERS WILL INSPECT AND TIGHTEN THE CONNECTION. VEHICLES WITH VISIBLE DAMAGE TO THE PLASTIC POWER DISTRIBUTION BOX HOUSING WILL HAVE THE THE UNDERHOOD HARNESS, INCLUDING THE POWER DISTRIBUTION BOX, REPLACED.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
14EA08021 · Engine Compartment Fires
Opened Sep 17, 2008 · Closed Oct 14, 2009
Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Service Brakes, Hydraulic; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module ; Vehicle Speed Control; Vehicle Speed Control:cruise Control
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Additional source detail variants (7)
Electrical System
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Electrical System:wiring
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Service Brakes, Hydraulic
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Vehicle Speed Control:cruise Control
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Vehicle Speed Control
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
PE08035 · Engine Compartment Fires
Opened May 13, 2008 · Closed Sep 17, 2008
Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Vehicle Speed Control
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
Additional source detail variants (3)
Electrical System
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
Electrical System:wiring
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
Vehicle Speed Control
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
RQ04003 · Hydraulic Brake Line Failure
Opened May 27, 2004 · Closed Oct 7, 2004
Status: closed (inferred from source dates) · Service Brakes, Hydraulic; Service Brakes, Hydraulic:fluid; Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Additional source detail variants (3)
Service Brakes, Hydraulic:fluid
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Service Brakes, Hydraulic
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
RQ02011 · Fuel Tank Fatigue Cracking
Opened Aug 29, 2002 · Closed Mar 14, 2003
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
SEE ATTACHED REPORT.
EA00027 · Suspension Coil Spring Breakage
Opened Dec 8, 2000 · Closed Jul 31, 2001
Status: closed (inferred from source dates) · Suspension
There is no summary currently available
Additional source detail variants (2)
Suspension
There is no summary currently available
Suspension
There is no summary currently available
PE00024 · Suspension Coil Spring Breakage
Opened Jun 23, 2000 · Closed Dec 8, 2000
Status: closed (inferred from source dates) · Suspension
There is no summary currently available
EA99020 · Fuel Tank Cracks
Opened Jul 26, 1999 · Closed Dec 16, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline
There is no summary currently available
PE99025 · Fuel Tank Cracks
Opened Apr 15, 1999 · Closed Jul 26, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline
There is no summary currently available
PE98056 · Rear Axle Trailing Arm
Opened Oct 28, 1998 · Closed Feb 24, 1999
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
DP98004 · Automatic Transmission Failure
Opened May 18, 1998 · Closed Jul 2, 1998
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
EA97018 · Outer Hood Panel Detachment
Opened Sep 30, 1997 · Closed Oct 22, 1997
Status: closed (inferred from source dates) · Structure
There is no summary currently available
PE97011 · Outer Hood Panel Detachment
Opened Mar 13, 1997 · Closed Sep 30, 1997
Status: closed (inferred from source dates) · Structure
THE OFFICE OF DEFECTS INVESTIGATION HAS RECEIVED 6 REPORTS INDICATING THE OUTER HOOD PANEL SEPARATED FROM THE VEHICLES AS THEY WERE BEING DRIVEN.FORD HAS PROVIDE 39 ADDITIONAL REPORTS THAT ARE CONSISTENT WITH ODI REPORTS.FORD INDICATES THAT THE LIKELY CAUSE IS PRIOR COLLISION DAMAGE.THIS INVESTIGATION IS BEING UPGRADED TO FURTHER STUDY THIS ISSUE.
EA96026 · Brake Pedal Fade/extended Stop Distance
Opened Oct 31, 1996 · Closed Feb 18, 2000
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE96042 · Brake Pedal Fade/extended Stopping
Opened Jun 13, 1996 · Closed Oct 31, 1996
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
ODI HAS RECEIVED SIXTY-EIGHT (68) CONSUMER REPORTS OF ALLEGED FAILURES OR MALFUNCTIONS IN THE BRAKE SYSTEM ON CERTAIN 1995 AND 1996 FORD WINDSTARS, WHICH RESULTED IN BRAKE PEDAL FADE AND IN EXTENDED STOPPING DISTANCES DURING BRAKINGTHESE ALLEGED FAILURES OR MALFUNCTIONS ARE REPORTED TO HAVE CAUSED TWELVE (12) ACCIDENTS THAT RESULTED FROM VEHICLE LOSS OF BRAKING.THE CONPLAINANTS REPORT THAT THE LOSS OF BRAKING OCCURRED DURINGBRAKING SITUATIONS ON DRY ROADS AS WELL AS ON WET OR SLIPPERY ROADS.IN RESPONSE TO ODI'S INFORMATION REQUES (IR) CONCERNING THE LONG STOPPING DISTANCE COMPLAINTS ON THE 1995 WINDSTAR, FORD REPORTED RECEIVING 259 REPORT (FIELD REPORTS, OWNER COMPLAINTS, AND SUBROGATION CLAIMS) OF LONG STOPPING DISTANCE ON THE 1995 FORD WINDSTAR, ALONG WITH 64 REPORTS OF ACCIDENTS.IN ADDITION, FORD REPORTED RECEIVING SOME 64,000 WARRANTY CLAIMS THAT COULD RELATE TO THE ALLEGED DEFECT OF LONG STOPPING DISTANCE PERFORMANCE ON THE SUBJECT VEHICLES.SINCE APRELIMINARY EVALUATION WAS OPENED, ODI HAS RECEIVED ADDITIONAL COMPLAINTS OF THE ALLEGED FAILURE ON THE 1996 MODELS, WHICH WERE NOT INCLUDED INITIALLY IN THIS INVESTIGATION.ODI BELIEVES THAT AN ENGINEERING ANALYSIS ON THE 1995 AND 1996 FORD WINDSTAR VEHICES IN WARRANTED TO DETERMINE THE SCOPE OF THE PROBLEM.