Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 7 of 227 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
Engine And Engine Cooling. Review the 61 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Seat Belts. Review the 61 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Electrical System. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
16 crash reports5 fire reports14 injury reports
What owners actually said
227 reports
95,000 miles · Sep 15, 2009
Electrical System
TL*THE CONTACT OWNS A 1993 FORD TEMPO. WHILE DRIVING APPROXIMATELY 35 TO 40 MPH ON NORMAL ROAD CONDITIONS; THE VEHICLE STALLED WITHOUT WARNING. THE ENGINE RESTARTED AND RESUMED OPERATION; HOWEVER, IT STALLED ON THREE TIMES. THE VEHICLE WAS INSPECTED BY A CERTIFIED MECHANIC. THE FAILURE WAS CONTRIBUTED TO THE IGNITION MODULE WHIC…
Read full complaint
TL*THE CONTACT OWNS A 1993 FORD TEMPO. WHILE DRIVING APPROXIMATELY 35 TO 40 MPH ON NORMAL ROAD CONDITIONS; THE VEHICLE STALLED WITHOUT WARNING. THE ENGINE RESTARTED AND RESUMED OPERATION; HOWEVER, IT STALLED ON THREE TIMES. THE VEHICLE WAS INSPECTED BY A CERTIFIED MECHANIC. THE FAILURE WAS CONTRIBUTED TO THE IGNITION MODULE WHICH HAS NOT BEEN REPAIRED. THE CONTACT HAD CONCERNS OF THE SAFETY RISK INVOLVED. THE FAILURE MILEAGE WAS 95,000 AND THE CURRENT MILEAGE WAS 96,000.
NHTSA ODI #10284061
40,000 miles · Jun 27, 2008
Electrical System
TL*THE CONTACT OWNS A 1993 FORD TEMPO. THE ENGINE WOULD NOT TURN OVER, BUT WHEN THE KEY WAS SLIGHTLY TURNED IN THE IGNITION, SOMETHING ELECTRICAL IN THE VEHICLE WOULD START. WHEN THE CONTACT CHANGES THE KEY SLIGHTLY IN THE IGNITION, HE LOSES ALL POWER AND CAN HEAR AN ELECTRICAL SPARK AS IF IT IS ATTEMPTING TO MAKE A CONNECTION…
Read full complaint
TL*THE CONTACT OWNS A 1993 FORD TEMPO. THE ENGINE WOULD NOT TURN OVER, BUT WHEN THE KEY WAS SLIGHTLY TURNED IN THE IGNITION, SOMETHING ELECTRICAL IN THE VEHICLE WOULD START. WHEN THE CONTACT CHANGES THE KEY SLIGHTLY IN THE IGNITION, HE LOSES ALL POWER AND CAN HEAR AN ELECTRICAL SPARK AS IF IT IS ATTEMPTING TO MAKE A CONNECTION. THE VEHICLE GOES FROM HAVING NO POWER TO POWER, DEPENDING ON THE SPARKING. THE VEHICLE WAS TAKEN TO THE DEALER ON THREE DIFFERENT OCCASIONS FOR THIS FAILURE. WHILE ATTEMPTING TO REPAIR THE VEHICLE, THE BATTERIES HAVE BEEN REPLACED THREE TIMES. A NEW BATTERY WAS RECENTLY INSTALLED IN THE VEHICLE AND THE FUSES WERE REPLACED ON FOUR OCCASIONS. IN ADDITION, THE STARTER WAS REPLACED, THE TERMINAL CABLES WERE REPLACED THREE TIMES, AND THE VEHICLE HAD MORE TUNE-UPS THAN WHAT WAS NECESSARY IN ORDER TO DIAGNOSE THE FAILURE. THE CONTACT WAS INFORMED THAT HIS VIN WAS EXCLUDED FROM NHTSA CAMPAIGN ID NUMBER 96V071000 (ELECTRICAL SYSTEM: IGNITION). THE CURRENT MILEAGE WAS 108,000 AND FAILURE MILEAGE WAS 40,000.
NHTSA ODI #10232531
Mileage unknown · Oct 31, 2005
Tires
DURING ROUTINE MAINTENANCE A LARGE BULGE APPROXIMATELY 6 INCHES IN LENGTH AND 3 INCHES WIDE WAS FOUND IN THE TREAD OF THE TIRE NEAR THE SIDEWALL. THE NAME OF THE TIRE IS CORDOVAN NOVA 70 METRIC RADIAL AND IS MADE IN BRAZIL. *NM
NHTSA ODI #10141248
Mileage unknown · Mar 31, 2005
Tires
ALL FOUR TIRES DEVELOPED SLIPPED BELTS, WHICH CAUSED THE VEHICLE TO SHAKE, MAKING IT DIFFICULT TO CONTROL VEHICLE. THERE WERE NO CURRENT RECALLS ON THIS PARTICULAR TYPE OF TIRE.*AK
NHTSA ODI #10117149
78,000 miles · Oct 24, 2004
Fuel System, Other
INTERMITENTLY RANDOM STALLING. CAR WILL NOT START FOR A FEW MINUTES. THEN, EVERYTHING SEEMS OKAY, AND CAR RUNS FINE. CONSUMER ISOALTED PROBLEM TO FUEL PUMP RELAY INSIDE "CONSTANT CONTROL" RELAY BOX. REPLACING THIS MODULE COMPLETELY CORRECTED PROBLEM. YOU CAN ISOLATE THIS PROBLEM BY PUTTING A VOLT-METER ON INPUT AND OUTPUT OF R…
Read full complaint
INTERMITENTLY RANDOM STALLING. CAR WILL NOT START FOR A FEW MINUTES. THEN, EVERYTHING SEEMS OKAY, AND CAR RUNS FINE. CONSUMER ISOALTED PROBLEM TO FUEL PUMP RELAY INSIDE "CONSTANT CONTROL" RELAY BOX. REPLACING THIS MODULE COMPLETELY CORRECTED PROBLEM. YOU CAN ISOLATE THIS PROBLEM BY PUTTING A VOLT-METER ON INPUT AND OUTPUT OF RELAY. THEN, WHEN PROBLEM OCCURS, THE INPUT WILL BE HIGH (12V), BUT THERE WILL BE NO OUTPUT FROM RELAY, PROVING BAD RELAY. I HAVE KEPT THIS MODULE IF WANTED FOR TESTING/INSPECTION. CONSUMERS HAVING STALLING PROBLEM CAN CONTACT ME AT OSPAMCHRIS_LAWSON@YAHOO.COM (REMOVE "NOSPAM.) *AK
NHTSA ODI #10096310
22,400 miles · Apr 23, 2004
Electrical System
THE IGNITION SWITCH EXPERIENCED AN INTERNAL SHORT CIRCUIT WHICH RESULTED IN VEHICLE NOT STARTING. RECALL 96V071000 WAS ISSUED, BUT THIS VEHICLE WAS NOT INCLUDED DUE TO VIN. *AK
NHTSA ODI #10071441
58,000 miles · Nov 24, 2003
Engine And Engine CoolingUnknown Or Other
WHILE DRIVING AT 25 MPH, THE VEHICLE STARTED SMOKING UNDER THE HOOD. THE CONSUMER DROVE TO A NEAR-BY MECHANIC, WHO DISCONNECTED THE BATTERY CABLES. THE MECHANIC FOUND THAT THE MOTOR MOUNTS WERE WORN, THE ENGINE NEEDED TO BE REBUILT AND THE HEAD GASKETS WERE LEAKING. THE SPEEDOMETER WAS ALSO INOPERABLE. THE DEALER AND THE MANUF…
Read full complaint
WHILE DRIVING AT 25 MPH, THE VEHICLE STARTED SMOKING UNDER THE HOOD. THE CONSUMER DROVE TO A NEAR-BY MECHANIC, WHO DISCONNECTED THE BATTERY CABLES. THE MECHANIC FOUND THAT THE MOTOR MOUNTS WERE WORN, THE ENGINE NEEDED TO BE REBUILT AND THE HEAD GASKETS WERE LEAKING. THE SPEEDOMETER WAS ALSO INOPERABLE. THE DEALER AND THE MANUFACTURER WILL BE INFORMED OF THE PROBLEMS. *JB
NHTSA ODI #10048562
Mileage unknown · Aug 21, 2003
Electrical SystemFuel System, GasolinePower Train
BECAUSE I'M NOT THE ORIGINAL OWNER THEY HAVE REFUSED TO REPAIR MY CAR. I'VE PUT ALOT OF MONEY IN MY CAR AND I'M STILL HAVING PROBLEMS WITH IT. FROM IT CUTTING OFF WHEN I STOP TO CONSTANTLY HAVING TO GET MY ROTORS TURN . I WOULD LIKE TO KNOW HOW CAN I GET HELP? THEY DON'T EVEN SEND ME RECALL NOTICES. I WAS SURFING THE NET TONIGHT…
Read full complaint
BECAUSE I'M NOT THE ORIGINAL OWNER THEY HAVE REFUSED TO REPAIR MY CAR. I'VE PUT ALOT OF MONEY IN MY CAR AND I'M STILL HAVING PROBLEMS WITH IT. FROM IT CUTTING OFF WHEN I STOP TO CONSTANTLY HAVING TO GET MY ROTORS TURN . I WOULD LIKE TO KNOW HOW CAN I GET HELP? THEY DON'T EVEN SEND ME RECALL NOTICES. I WAS SURFING THE NET TONIGHT AND MOST OF THE PROBLEMS I HAVE WITH MY CAR IT'S LISTED IN THE RECALL LIST.MY CAR IS A 1993 FORD TEMPO.PLEASE HELP ME AS SOON AS YOU CAN BEFORE I HAVE A MAJOR ACCIDENT( MY BRAKES ACT LIKE THEY DON'T WONT TO STOP).THANK YOU FOR HEARING ME OUT. SINCERELY [XXX]. *AK INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6). *TR
NHTSA ODI #10033227
Mileage unknown · Jun 30, 2003
Engine And Engine Cooling
CONSUMER STATES THAT THE VEHICLE STALLS INTERMITTENTLY WHILE DRIVING.*AK
NHTSA ODI #10026206
Mileage unknown · Jun 19, 2003
Latches/locks/linkages
AUTOMATIC SYSTEM, NEITHER THE MANUAL ON THE FRONT PASSENGER AND THE DRIVER REAR SIDE DOORS CAN'T OPEN. EALER HAS REPAIREDEVERAL TIMES,AND PROBLEM IS OCCURRING.*AK
THESE VEHICLES ARE ORIGINALLY SOLD OR CURRENTLY REGISTERED IN THE FOLLOWING STATES: ALASKA, IOWA, MINNESOTA, NEBRASKA, NORTH DAKOTA, AND SOUTH DAKOTA. THE VEHICLES INVOLVED ARE 1992-1994 TEMPO/TOPAZ VEHICLES WITH 3.0L ENGINES; 1994 TEMPO/TOPAZ WITH 2.3L ENGINES; 1992-1995 TAURUS/SABLE WITH 3.8L ENGINES; 1994-1995 TAURUS/SABLE WITH 3.0L ENGINES AND 1992-1994 LINCOLN CONTINENTAL VEHICLES WITH 3.8L ENGINES. DURING HIGH WINDS, HEAVY, BLOWING AND DRIFTING SNOW, AND LOW TEMPERATURES, THE ENGINE COOLING FAN CAN BECOME BLOCKED OR FROZEN WITH SNOW. THE FAN MOTOR MAY NOT ROTATE AND COULD OVERHEAT.
Consequence & remedy
Consequence: THIS CONDITION CAN CAUSE SMOKE OR FLAMES FROM THE FAN AND/OR SHROUD, THE FAN ELECTRICAL WIRING, OR THE FAN MOTOR RESULTING IN A VEHICLE FIRE.
Remedy: DEALERS WILL INSTALL AN ELECTRICAL JUMPER HARNESS CONTAINING AN AUTOMATIC RESETTING CIRCUIT BREAKER TO PROTECT THE FAN MOTOR LOW SPEED CIRCUITRY FROM OVERHEATING.
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2
EA96024 · Engine Cooling Fan Fires
Opened Sep 30, 1996 · Closed Apr 15, 1997
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
PE96033 · Engine Cooling Fan Fires
Opened May 2, 1996 · Closed Sep 30, 1996
Status: closed (inferred from source dates) · Engine And Engine Cooling
IN DECEMBER 1995, FORD RECALLED 119,313 VEHICLES IN CANADA TO REMEDY THE SUBJECT CONDITION IN CERTAIN 1992-95 TAURUS, SABLE, TEMPO, TOPAZ AND CONTINENTAL VEHICLES.FORD IS AWARE OF SIMILAR INCIDENTS OCCURRING IN NORTHERN REGIONS OF THE UNITED STATES, BUT MAINTAINS THAT THE FREQUENCIES DO NOT WARRANT A FINDING OF AN UNREASONABLE RISK TO MOTOR VEHICLE SAFETY.
1993 Ford Tempo Problems, Complaints & Recalls | Skip That Year