NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
39 reports44,470 miles · Jul 15, 2005
Fuel System, Gasoline
DT: THE CROSS OVER OF THE FUEL IMPROPERLY OVERFILLS THE SECOND TANK, SPILLING FUEL OUT OF VEHICLE. THERE WERE 2 SAFETY RECALLS OF THIS ITEM. BUT FORD WAS SAYING THAT ONE RECALL WAS TAKEN CARE OF BY A PREVIOUS OWNER. THE SECOND RECALL EXPIRED, AND FORD WILL NOT FIX THIS PROBLEM. FORD HAS BEEN CONTACTED BY THE CUSTOMER AND THE RE…
Read full complaint
DT: THE CROSS OVER OF THE FUEL IMPROPERLY OVERFILLS THE SECOND TANK, SPILLING FUEL OUT OF VEHICLE. THERE WERE 2 SAFETY RECALLS OF THIS ITEM. BUT FORD WAS SAYING THAT ONE RECALL WAS TAKEN CARE OF BY A PREVIOUS OWNER. THE SECOND RECALL EXPIRED, AND FORD WILL NOT FIX THIS PROBLEM. FORD HAS BEEN CONTACTED BY THE CUSTOMER AND THE REPAIR FACILITY. FORD WAS STILL NOT WILLING TO HELP. THIS HAS BEEN A PROBLEM FOR A COUPLE OF MONTHS. THE CUSTOMER WAS HAVING IT REPAIRED AT HIS OWN EXPENSE. IF THERE WAS A SAFETY ISSUE ON THIS PROBLEM IT SHOULD BE TAKEN CARE OFF BY DEALER NO MATTER HOW MANY TIMES IT COMES UP.*AK *JB
NHTSA ODI #10125621
180,000 miles · Aug 27, 2004
Fuel System, Gasoline
VEHICLE WAS TAKEN TO DEALER FOR RECALL REPAIRS ABOUT 5 YEARS AGO. VEHICLE HAD DUEL GAS TANKS. THE RECALL WAS ISSUED BECAUSE ONE TANK WOULD PUMP GAS INTO THE OTHER TANK, AND WHEN IT WAS FULL IT WOULD SPILL OVER, CREATING A FIRE HAZARD. AFTER RECALL REPAIRS WERE DONE THE PROBLEM RECURRED. CONSUMER FELT THAT THE PROPER WORK FO…
Read full complaint
VEHICLE WAS TAKEN TO DEALER FOR RECALL REPAIRS ABOUT 5 YEARS AGO. VEHICLE HAD DUEL GAS TANKS. THE RECALL WAS ISSUED BECAUSE ONE TANK WOULD PUMP GAS INTO THE OTHER TANK, AND WHEN IT WAS FULL IT WOULD SPILL OVER, CREATING A FIRE HAZARD. AFTER RECALL REPAIRS WERE DONE THE PROBLEM RECURRED. CONSUMER FELT THAT THE PROPER WORK FOR THE RECALL WAS INSUFFICIENTLY DONE BECAUSE OF WHAT WAS HAPPENING CURRENTLY. *AK
NHTSA ODI #10089939
1,500 miles · Jul 11, 2003
Tires
WHILE TRAVELING, THE CONSUMER HEARD A LOUD POPPING NOISE. THE CONSUMER PULLED OVER AND SAW THE RIGHT FRONT TIRE TREAD SEPARATED FROM THE WHEEL. FIRESTONE STEELTEX, LT 265/75R16. *AK *SCC *JB
NHTSA ODI #10024386
Mileage unknown · Feb 7, 2002
Fuel System, Gasoline
I AM SPEAKING ON BEHALF OF THE OWNER, I AM TED SCHORE OF OCALA,FL PINEYWOODS AUTOMOTIVE 352-629-6727 THE CUSTOMER HAD THE TRUCK TOWED IN BECAUSE OF A NO START (BATTERY WAS BAD) AND AFTER THE REPAIR AND RUNNING NOTICED A FUEL SMELL AND LARGE FUEL LEAK FROM THE BELL HOUSING AREA. THE LEAK WAS FROM THE FUEL RETURN LINE FROM THE PRE…
Read full complaint
I AM SPEAKING ON BEHALF OF THE OWNER, I AM TED SCHORE OF OCALA,FL PINEYWOODS AUTOMOTIVE 352-629-6727 THE CUSTOMER HAD THE TRUCK TOWED IN BECAUSE OF A NO START (BATTERY WAS BAD) AND AFTER THE REPAIR AND RUNNING NOTICED A FUEL SMELL AND LARGE FUEL LEAK FROM THE BELL HOUSING AREA. THE LEAK WAS FROM THE FUEL RETURN LINE FROM THE PRESSURE REGULATOR TO THE CONNECTION TO THE LINE FROM THE TANK, APPROX 12 INCHES LONG AND METAL. THE PINCH WELD ABOVE THE BELL HOUSING RUBBED THE LINE THROUGH. I CHECK FOR SERVICE BULLETINS AND RECALLS AND FOUND A RECALL NUMBER 94S80, I CALLED THE LOCAL FORD DEALER TO ARRANGE TOWING AND FOR THE RECALL TO BE PERFORMED AND WAS TOLD THE RECALL HAD ALREADY BEEN DONE BY BAY HARBOR FORD IN ENGLEWOOD FLORIDA. I CALLED THE 1-800 NUMBER GIVEN TO ME BY THE LOCAL DEALER (DEARBORN?) AND WAS TOLD THE IT HAD INDEED BEEN DONE BUT THEY WERE NOT GOING TO DO ANYTHING ABOUT IT NOW, I INFORMED THEM THAT ALTHOUGH THEY SHOW IT BEING DONE THAT IT WAS NOT THEY PRETTY MUCH SAID IT WAS NOT FORDS PROBLEM AND THE CUSTOMER WOULD HAVE TO PAY TO HAVE IT REPAIRED. WELL MY PROBLEM IS THIS. THE BAY HARBOR FORD HAS BEEN PAID TO PERFORM THE RECALL BUT IT HAS NOT BEEN DONE. THE OLD LINE WAS METAL WHERE THE NEW RECALL WAS FOR A PLASTIC LINE, THE KIT ALSO HAD A VINYL TRIM PIECE TO COVER THE PINCH WELD THAT RUBBED THE LINE IN THE FIRST PLACE. THE KIT NUMBER FROM FORD WAS F4TZ-9J332-A I WAS TOLD IT WAS ON NATIONAL BACK ORDER BUT THE PARTS MAN WAS ABLE TO GET IT THROUGH ANOTHER FORD DEALER. I JUST WANTED TO INFORM YOU OF THIS BECAUSE IT WAS A REAL FIRE DANGER AND UNSAFE TO DRIVE. FORD"S ATTITUDE WAS JUST PLAIN WRONG. I WOULD THINK THAT THE DEARBORN OFFICE WOULD HAVE PAID TO HAVE THE TRUCK TOWED TO THE NEAREST DEALER, INSPECTED, MADE NOTE OF THE RECALL NOT BEING DONE, PERFORMED THE RECALL AND GO AFTER BAY HARBOR FORD, BUT IN SO MANY WORDS I WAS TOLD TOUGH. I THINK I SAVED THEM FROM A BIG LAWSUIT AS THE CUSTOMER HAULS HORSES. BIG DOLLAR HORSES.
NHTSA ODI #757905
Mileage unknown · Feb 1, 2002
Fuel System, Gasoline
THERE HAS BEEN MULTIPLE RECALL NOTICES FOR THE FORD F-SERIES DUAL FUEL TANK DESIGN FLAW. WHEN BOTH TANKS ON MY TRUCK ARE FILLED TO CAPACITY, ONE TANK WILL EMPTY ITS CONTENTS INTO THE OTHER FULL FUEL TANK AND WILL SPRAY OUT FUEL ON TO THE ROAD AND OTHER VEHICLES POSING A GREAT FIRE HAZARD. EACH TIME I HAVE TAKEN MY TRUCK IN TO HA…
Read full complaint
THERE HAS BEEN MULTIPLE RECALL NOTICES FOR THE FORD F-SERIES DUAL FUEL TANK DESIGN FLAW. WHEN BOTH TANKS ON MY TRUCK ARE FILLED TO CAPACITY, ONE TANK WILL EMPTY ITS CONTENTS INTO THE OTHER FULL FUEL TANK AND WILL SPRAY OUT FUEL ON TO THE ROAD AND OTHER VEHICLES POSING A GREAT FIRE HAZARD. EACH TIME I HAVE TAKEN MY TRUCK IN TO HAVE THE RECALL PERFORMED ON MY TRUCK BY THE LOCAL DEALER (MCCULLOM FORD IN SPOKANE WA) THEY HAVE RETURNED MY TRUCK WITHOUT FIXING THE PROBLEM. THEY HAVE INDICATED THAT THEY HAVE PERFORMED FORDS RECOMMENDED FIX AND THAT IT HAS NOT SOLVED THE PROBLEM. THIS IS A FORD MOTOR CO. DESIGN FLAW. I WOULD LIKE MORE INFORMATION ON HOW I CAN HAVE THIS UNSAFE CONDITION ADDRESSED. THANK YOU.*AK
NHTSA ODI #757633
Mileage unknown · Oct 15, 2001
Engine And Engine CoolingFire
WHILE DRIVING EMERGENCY SPARE TIRE UNDERNEATH VEHICLE CAUGHT ON FIRE. FIRE WAS CAUSED BY EXHAUST PIPE BEING TOO CLOSE. MANUFACTURER NOTIFIED. FEEL FREE TO PROVIDE ANY FURTHER INFORMATION.*AK
NHTSA ODI #897741
Mileage unknown · Feb 20, 2001
Fuel System, Gasoline
93 V 125 000/FUEL TANK ASSEMBLY: VEHICLE EXPERIENCED A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK. WHEN THIS OCCURRED SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILLED FUEL COULD RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER NOTIFIED, AND INFORMED CONSUMER THAT VIN SHOWED THAT R…
Read full complaint
93 V 125 000/FUEL TANK ASSEMBLY: VEHICLE EXPERIENCED A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK. WHEN THIS OCCURRED SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILLED FUEL COULD RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER NOTIFIED, AND INFORMED CONSUMER THAT VIN SHOWED THAT RECALL REPAIRS WERE DONE ON THIS VEHICLE. BUT PROBLEM HAS REOCCURRED, AND DEALER REFUSED TO HELP IN THIS MATTER. PLEASE FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER: *AK
NHTSA ODI #880905
Mileage unknown · Nov 21, 2000
Tires
THIS PARTICULAR TIRE EXPLODED @ ABOUT 60 MPH ON MY TRUCK .I HAD A 5TH WHEEL TRAILER ON BEHIND AT THE TIME . IT CAUSED 1150.00 DOLLARS DAMAGE TO THE TRUCK. THIS IS THE 7TH OR EIGHTH TIRE OF THE SAME BRAND &TYPE THAT I HAD GO BAD. THE OTHERS HAD THE BELTS COME LOOSE AND START VIBERATING. I WOULD TAKE THEM BACK TO A SEARS STORE AN…
Read full complaint
THIS PARTICULAR TIRE EXPLODED @ ABOUT 60 MPH ON MY TRUCK .I HAD A 5TH WHEEL TRAILER ON BEHIND AT THE TIME . IT CAUSED 1150.00 DOLLARS DAMAGE TO THE TRUCK. THIS IS THE 7TH OR EIGHTH TIRE OF THE SAME BRAND &TYPE THAT I HAD GO BAD. THE OTHERS HAD THE BELTS COME LOOSE AND START VIBERATING. I WOULD TAKE THEM BACK TO A SEARS STORE AND THEY WOULD GIVE ME AN ADJUSTMENT AND CHARGE ME 75% OF A NEW TIRE AND PUT THE SAME TYPE BACK ON. I WOULD QUESTION THEM ABOUT THE SAFTY OF THE TIRE & THEY WOULD JUST SHAKE THEIR HEADS. THE FIRST TWO TIRES WERE BOUGHT IN FARMINGTON NM. ON THE28TH OF JULY 1998.THE LAST TWO WERE BOUGHT THE 19 OF OCT.1999 . TWO MORE WERE REMOVED THE 6TH OF SEPT. 2000 BUT WERE REPLACED WITH DIFFERENT TYPE . IWAS TOLD THE QUIT MAKING IT IN MY SIZE. I STILL HAVE THREE IN MY POSESSION . ONE IS BLOWN AND THEY WANT ME TO SEND IT TO PIRELLI FOR EVAUATION. SEARS WANTS TO PASS THE BUCK TO PIRELLI . IT IS MY CONTENTION THE TIRES ARE DIFFENETLY DANGEROUS TO THE PUBLIC. I WAS VERY LUCKY TO HAVE BEEN ABLE TO BRING MY TRUCK UNDER CONTROL . I MIGHT ADD THAT THESE TIRES THAT HAVE LOST THEIR BELTS HAVE BEEN ON ALL FOR CORNERS OF THE TRUCK WHEN THEY WENT BAD. THANK YOU FOR YOUR TIME.*AK (DOT NUMBER: CHOR524 TIRESIZE: 235 85 R16)
NHTSA ODI #736729
Mileage unknown · Nov 15, 2000
Engine And Engine CoolingFuel System, Gasoline
CONSUMER WAS TRAVELING 60 MPH & VEHICLE STALLED. REAR FUEL TANK SPILLED GAS ALL OVER HIGHWAY. WHEN VEHICLE WAS BEING TOWED TO FORD DEALER FUEL TANK FELL OFF. SHIELD THAT GUARDS THE TANK DROPPED & GAS LINES WERE DISCONNECTED. *AK
NHTSA ODI #875008
Mileage unknown · Apr 13, 2000
Electrical System
BACK OF THE FUSE BOX MELTED, AND CONSUMER LOST ELECTRICAL POWER. *AK
NHTSA ODI #860301
Official recalls
6Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
PE94004 · Hydraulic Brake Line Cracks/leaks
Opened Jan 25, 1994 · Closed Apr 29, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91090 · Spare Tire Fires
Opened Jun 20, 1991 · Closed Oct 25, 1991
Status: closed (inferred from source dates) · Equipment
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
PE90056 · Trnsmssion Park Gear Fail
Opened Mar 12, 1990 · Closed Jun 12, 1990
Status: closed (inferred from source dates) · Power Train:automatic Transmission:gear Position Indication (prndl)
There is no summary currently available