← New search

1990 Ford F150

Owner reports · Recalls · Investigations

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all F150 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 25 of 254 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 129 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 34 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports30 fire reports9 injury reports

What owners actually said

254 reports
Mileage unknown · Feb 9, 2000
Fuel System, Gasoline

CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY FAILED PRIOR TO RECALL NOTICE CAUSING A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS THE CAPACITY IS EXCEEDED CAUSING FUELL SPILLAGE. FUEL LEAK HAS CAUSED PAINT AND MOLDING DAMAGE. NLM

NHTSA ODI #550831

Mileage unknown · Feb 8, 2000
Fuel System, Gasoline

EA99023;DUAL FUEL TANK CROSS/FLOW.LEAKAGE; FUEL PUMPS FROM THE REAR TANK INTO THE FRONT TANK, CAUSING FUEL SPILLAGE WHEN BOTH TANKS ARE FILLED AND THE PUMP IS TURNED ON. PROLBEM WAS REPORTED TO THE DEALERSHIP. THE PROBLEM WAS NOT CORRECTED. *AK

NHTSA ODI #854926

Mileage unknown · Feb 8, 2000
Fuel System, Gasoline

FUEL PUMP FAILED CAUSING FUEL TO LEAK FROM THE TANK WHEN THE PRESSURE BUILDS UP. NLM

NHTSA ODI #550793

Mileage unknown · Feb 4, 2000
Fuel System, Gasoline

VEHICLE HAS DUAL TANKS, AND FRONT TANK TRAVELS THOUGH THE REAR TANK. IF BOTH TANKS ARE FUEL, REAR ONE WILL SPILL OUT FASTER. IF ONE TANK IS EMPTY AND OTHER TANK IS FULL, THE OTHER GAS TANK WILL LEAK BECAUSE THE GAS WILL COME OUT QUICKER. *AK

NHTSA ODI #856305

Mileage unknown · Feb 1, 2000
Fuel System, Gasoline

A MALFUNCTIONING CHECK VALVUE IN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON THE MAKE/MODEL. HOWEVER ,THIS VEHICLE WAS NOT INCLUDED DUE TO THE VIN. DEALER AND MANUFACTURER HAVE BEEN NOTIFIED. *AK

NHTSA ODI #855908

Mileage unknown · Dec 21, 1999
Fuel System, Gasoline

WHEN BOTH TANKS ARE FULL AND WHEN FRONTAL TANK GETS LOW ON FUEL, REAR TANK DRAINS OFF FUEL FROM THE REAR TO THE FRONTAL TANK. CONSUMER HAS YET TO CONTACT THE DEALER. PLEASE PROVIDE ANY FURTHER DETAILS. *AK

NHTSA ODI #854223

Mileage unknown · Dec 21, 1999
Fuel System, Gasoline

I AM AN OTR TRUCK DRIVER AND I AM VERY AWARE OF PROBLEMS WITH ALL VEHICLES THAT I DRIVE. I CAME BACK TO MY WORK TERMINAL AND NOTICED A VERY STRONG SMELL OF GASOLINE COMING FROM MY TRUCK. I LOOKED UNDER IT AND SAW THAT THE REAR FUEL TANK WAS LEAKING QUITE OBVIOUSLY FROM THE SEAM. I CONTACTED MY LOCAL DEALERSHIP AND ASKED IF TH…

Read full complaint

I AM AN OTR TRUCK DRIVER AND I AM VERY AWARE OF PROBLEMS WITH ALL VEHICLES THAT I DRIVE. I CAME BACK TO MY WORK TERMINAL AND NOTICED A VERY STRONG SMELL OF GASOLINE COMING FROM MY TRUCK. I LOOKED UNDER IT AND SAW THAT THE REAR FUEL TANK WAS LEAKING QUITE OBVIOUSLY FROM THE SEAM. I CONTACTED MY LOCAL DEALERSHIP AND ASKED IF THERE WAS A RECALL ON THE FUEL TANK, HE SAID NO. I THEN WAS TOLD TO CONTACT FORD AND I ASKED IF THEY HAD A RECALL ON THIS VEHICLE AND THEY SAID THAT THE VEHICLE HAD BEEN THROUGH A RECALL FIX BACK IN 1993. I HARDLY THINK THAT A FUEL TANK THAT WAS REPAIRED WOULD START LEAKING 6 YEARS LATER, ESPECIALLY FROM THE SEAM ON THE TANK. I WAS TOLD THAT MY BUMPER TO BUMPER WARRANTY WAS UP AND THAT FORD WOULD NOT TAKE CARE OF MY PROBLEM. DEAR SIRS, I HAVE TWO CHILDREN AND A WIFE WHO DEPEND ON ME TO PROVIDE THE BEST CARE AND PROTECTION. HOW CAN I PROTECT MY FAMILY FROM COMPANIES THAT DON'T CARE ABOUT ANYONE AND ONLY CARE ABOUT THEIR POCKETBOOK. *AK

NHTSA ODI #716325

Mileage unknown · Dec 8, 1999
Fuel System, Gasoline

DUAL FUEL TANKS ARE DEFECTIVE, ALLOWING ONE TO OVERFLOW INTO THE OTHER AND SPILL GAS OUT OF THE VEHICLE. DEALER HAS REPAIRED UNDER RECALL BEFORE. PROBLEM EXISTS CURRENTLY. *AK

NHTSA ODI #853888

Mileage unknown · Dec 7, 1999
Fuel System, Gasoline

FORD WILL NOT AKNOWLEDGE RECALL INFORMATION CONCERNING FUEL TANK AUXILIARY SELECTOR AND SWITCH FAILURE. RECALL 89V141000. *AK

NHTSA ODI #853786

Mileage unknown · Nov 3, 1999
Fuel System, Gasoline

A PORTION OF THE UNUSED FUEL FROM ONE TANK IS RETURNING TO THE SECOND TANK, RESULTING IN FUEL SPILLAGE . THE VEHICLE HAS BEEN REPAIRED UNDER RECALL PRIOR TO THIS INCIDENT. THE DEALER AND MANUFACTURER HAVE BEEN NOTIFIED. *AK

NHTSA ODI #852498

Official recalls

4

96V071000 · Electrical System:ignition

Apr 25, 1996

THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence & remedy

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)

Jun 1, 1990

UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.

Consequence & remedy

Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.

Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.

89V141000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices

Aug 15, 1989

INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.

Consequence & remedy

Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.

Remedy: REPLACE FUEL LINE ASSEMBLY.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

10

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

EA92029 · Front Seat Back Failure

Opened Aug 27, 1992 · Closed Oct 29, 1993

Status: closed (inferred from source dates) · Seats

There is no summary currently available

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE91064 · Transmission Fluid Fires

Opened Apr 9, 1991 · Closed Jul 5, 1991

Status: closed (inferred from source dates) · Power Train

There is no summary currently available

PE91017 · Ford Truck Inconsistent Vehicle Control.

Opened Nov 27, 1990 · Closed Apr 17, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

SEE CLOSE RESUME