← New search

1990 Ford F150

Owner reports · Recalls · Investigations

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all F150 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 25 of 254 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 129 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 34 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports30 fire reports9 injury reports

What owners actually said

254 reports
180,000 miles · Mar 9, 2011
Fuel System, Gasoline

TL* THE CONTACT OWNS A 1990 FORD F-150. THE CONTACT STATED THAT GASOLINE FUEL WAS ABNORMALLY LEAKING FROM THE FUEL TANK AND THE REAR FUEL TANK WAS PUMPING FUEL INTO THE FRONT FUEL TANK. THE CONTACT LOCATED A RECALL UNDER NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM: TANK ASSEMBLY), BUT WAS INFORMED BY THE MANUFACTURER THAT T…

Read full complaint

TL* THE CONTACT OWNS A 1990 FORD F-150. THE CONTACT STATED THAT GASOLINE FUEL WAS ABNORMALLY LEAKING FROM THE FUEL TANK AND THE REAR FUEL TANK WAS PUMPING FUEL INTO THE FRONT FUEL TANK. THE CONTACT LOCATED A RECALL UNDER NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM: TANK ASSEMBLY), BUT WAS INFORMED BY THE MANUFACTURER THAT THE RECALL WAS EXPIRED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 180,000.

NHTSA ODI #10386980

86,000 miles · Oct 8, 2009
Fuel System, Gasoline

TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WERE TWO FUEL TANKS IN HER VEHICLE. WHEN SHE ADDED FUEL TO THE INTENDED TANK, IT WOULD FORCE FUEL INTO THE AUXILIARY TANK AND LEAK OUT OF THE TANK. THE FAILURE OCCURRED EVERY TIME FUEL WAS ADDED TO THE VEHICLE. THE DEALER STATED THAT RECALL #93V125000 EXPIRED; …

Read full complaint

TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WERE TWO FUEL TANKS IN HER VEHICLE. WHEN SHE ADDED FUEL TO THE INTENDED TANK, IT WOULD FORCE FUEL INTO THE AUXILIARY TANK AND LEAK OUT OF THE TANK. THE FAILURE OCCURRED EVERY TIME FUEL WAS ADDED TO THE VEHICLE. THE DEALER STATED THAT RECALL #93V125000 EXPIRED; HOWEVER, THEY WOULD REPAIR THE VEHICLE AT NO COST. THE MANUFACTURER WAS NOT NOTIFIED. THE VEHICLE HAS NOT BEEN REPAIRED. THE CURRENT MILEAGE WAS 86,236. THE FAILURE MILEAGE WAS APPROXIMATELY 86,000.

NHTSA ODI #10286746

118,000 miles · Apr 30, 2009
Fuel System, Gasoline

TL*THE CONTACT OWNS A 1990 FORD F150. AFTER FILLING BOTH OF THE GAS TANKS IN THE VEHICLE, THE CONTACT NOTICED THE FUEL LEVEL DECREASING. THE FAILURE WAS NOTICED WHILE DRIVING 30 MPH. AFTER DRIVING FOR TEN MILES, HE PULLED THE VEHICLE OVER AND NOTICED FUEL LEAKING FROM THE REAR GAS TANK. THE CONTACT SWITCHED THE FUEL USAGE TO…

Read full complaint

TL*THE CONTACT OWNS A 1990 FORD F150. AFTER FILLING BOTH OF THE GAS TANKS IN THE VEHICLE, THE CONTACT NOTICED THE FUEL LEVEL DECREASING. THE FAILURE WAS NOTICED WHILE DRIVING 30 MPH. AFTER DRIVING FOR TEN MILES, HE PULLED THE VEHICLE OVER AND NOTICED FUEL LEAKING FROM THE REAR GAS TANK. THE CONTACT SWITCHED THE FUEL USAGE TO THE FRONT FUEL TANK. THE VEHICLE WAS TAKEN TO A LOCAL REPAIR SHOP, BUT THE TECHNICIAN COULD NOT DETERMINE THE CAUSE OF THE FAILURE. THE TECHNICIAN ADVISED THE CONTACT TO TAKE THE VEHICLE TO THE DEALER FOR FURTHER INSPECTION. HE DISCOVERED NHTSA CAMPAIGN ID NUMBERS 01I008000 (FUEL SYSTEM, GASOLINE) AND 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE DEALER STATED THAT THE BA AND AA CONNECTORS, GASKET, TWO RETAINERS, TWO FUEL FILTERS, VALVES, AND THE O RING ON THE TANK HAD ALL FAILED. THE VEHICLE WAS REPAIRED AT THE COST OF $765.47. THE CONTACT IS IN THE PROCESS OF NOTIFYING THE MANUFACTURER. THE FAILURE MILEAGE WAS 118,000 AND CURRENT MILEAGE WAS 123,487. UPDATED 5/27/09 *CN THE CONSUMER STATED GAS STARTED TRANSFERRING FROM ONE TANK TO ANOTHER. UPDATED 06/02/09.*JB

NHTSA ODI #10267314

160,000 miles · Oct 7, 2008
Fuel System, Gasoline

TL*THE CONTACT OWNS A 1990 FORD F150. WHILE THE ENGINE WAS OPERATING, FUEL WAS LEAKING OUT OF THE FILLER NECK OF THE FRONT FUEL TANK IN LARGE AMOUNTS. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC AND THEY REFERENCED NHTSA CAMPAIGN ID NUMBER 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE RECALL STATES THAT A …

Read full complaint

TL*THE CONTACT OWNS A 1990 FORD F150. WHILE THE ENGINE WAS OPERATING, FUEL WAS LEAKING OUT OF THE FILLER NECK OF THE FRONT FUEL TANK IN LARGE AMOUNTS. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC AND THEY REFERENCED NHTSA CAMPAIGN ID NUMBER 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE RECALL STATES THAT A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. THE CURRENT AND FAILURE MILEAGES WERE LESS THAN 160,000. UPDATED 11/07/08 *BF UPDATED 11/13/08.*JB

NHTSA ODI #10244625

95,000 miles · Apr 7, 2008
Fuel System, Gasoline

EXPERIENCING CROSS FILL BETWEEN DUAL TANKS IN 1990 FORD F150. CAN CAUSE DANGEROUS OVERFLOW AND GAS SPILL. CONTACTED LOCAL FORD DEALER WHO SAID MY TRUCK IS NOT COVERED UNDER RECALL. CONTACTED FORD MOTOR COMPANY WHO SAID THAT RECALLS ARE "VIN SPECIFIC". EVEN THOUGH OTHER FORDS OF THE SAME YEAR AND MODEL, WITH THE SAME PROBLE…

Read full complaint

EXPERIENCING CROSS FILL BETWEEN DUAL TANKS IN 1990 FORD F150. CAN CAUSE DANGEROUS OVERFLOW AND GAS SPILL. CONTACTED LOCAL FORD DEALER WHO SAID MY TRUCK IS NOT COVERED UNDER RECALL. CONTACTED FORD MOTOR COMPANY WHO SAID THAT RECALLS ARE "VIN SPECIFIC". EVEN THOUGH OTHER FORDS OF THE SAME YEAR AND MODEL, WITH THE SAME PROBLEM ARE COVERED.... MINE IS NOT. THIS IS A DANGEROUS WIDESPREAD PROBLEM FOR WHICH FORD SHOULD BE HELD ACCOUNTABLE. *TR

NHTSA ODI #10223579

10,200 miles · Jan 17, 2008
Fuel System, Gasoline

FUEL TANKS TRANSFER FUEL QUANTITIES FROM ONE TO THE OTHER. THIS HAS ALREADY RESULTED IN ONE INSTANCE OF FUEL OVERFLOW AND AS A RESULT OWNER NO LONGER FILLS BOTH TANKS AT THE SAME TIME. OWNER DOES UNDERSTAND A RECALL HAS BEEN ORDERED FOR THIS DEFECT BUT DOES NOT HAVE PROPER INFORMATION TO PROCEED WITH REPAIRS. *TR

NHTSA ODI #10215259

102,000 miles · Jan 7, 2008
Fuel System, Gasoline

TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WAS FUEL LEAKAGE WHEN HE FILLED THE FUEL TANK. THE MECHANIC STATED THAT THE FRONT TANK LEAKED FUEL INTO THE REAR TANK WHICH CAUSED THE REAR TANK TO LEAK. THEY STATED THAT FUEL PUMP SENDER ASSEMBLY NEEDS TO BE REPLACED. THERE IS A RECALL FOR THE FUEL SYSTEM, G…

Read full complaint

TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WAS FUEL LEAKAGE WHEN HE FILLED THE FUEL TANK. THE MECHANIC STATED THAT THE FRONT TANK LEAKED FUEL INTO THE REAR TANK WHICH CAUSED THE REAR TANK TO LEAK. THEY STATED THAT FUEL PUMP SENDER ASSEMBLY NEEDS TO BE REPLACED. THERE IS A RECALL FOR THE FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY (NHTSA CAMPAIGN ID #93V125000) HOWEVER THE MANUFACTURER STATED THAT THE VIN WAS NOT INCLUDED. THE FAILURE MILEAGE WAS 102,000 AND CURRENT MILEAGE WAS 104,000. UPDATED 01/29/08 *LJ. UPDATED 01/29/08 *TR

NHTSA ODI #10214080

Mileage unknown · Nov 15, 2007
Fuel System, Gasoline

1990 FORD F-150 TRUCK HAS DUEL FUEL TANKS; FUEL IS PUMPING FROM THE BACK TANK TO THE FRONT TANK AND OVER SPILLING THROUGH THE FUEL CAP ONTO THE GROUND. LETTER FROM MANUFACTURER DATED 7-19-2001 STATES THAT THIS IS NOT A SAFETY RECALL AND THEREFORE THEY WILL NOT CORRECT PROBLEM. QUESTION: HOW CAN RECALLS FROM 8-15-1989 AND 8-2-199…

Read full complaint

1990 FORD F-150 TRUCK HAS DUEL FUEL TANKS; FUEL IS PUMPING FROM THE BACK TANK TO THE FRONT TANK AND OVER SPILLING THROUGH THE FUEL CAP ONTO THE GROUND. LETTER FROM MANUFACTURER DATED 7-19-2001 STATES THAT THIS IS NOT A SAFETY RECALL AND THEREFORE THEY WILL NOT CORRECT PROBLEM. QUESTION: HOW CAN RECALLS FROM 8-15-1989 AND 8-2-1993 WHICH CAUSED OVERFLOW AND SPILLAGE BE APPROVED AS A SAFETY RECALL; YET THE 7-19-2001 ISSUE WHICH RESULTS IN THE SAME OVERFLOW AND SPILLAGE NOT BE APPROVED AS A SAFETY RECALL? PROBLEM WITH THE OVERFLOW STARTED IN OCTOBER 2007 -- FUEL SPILLED DUE TO CROSS TANK FUEL FLOW. AT THIS POINT, ONLY ONE TANK CAN CONTAIN FUEL AND THE OTHER TANK MUST REMAIN EMPTY FOR THE SPILLAGE TO CEASE. *TR

NHTSA ODI #10209038

89,000 miles · May 15, 2007
Electrical System

TL*THE CONTACT OWNS A 1990 FORD F150. WHEN THE ENGINE SHUT OFF, THE VEHICLE CONTINUED TO RUN. THE DEALER INFORMED THE CONTACT THAT HIS VEHICLE WAS NOT A PART OF RECALL NUMBER 96V071000 (FOR THE IGNITION) AND HE WOULD NOT INSPECT THE VEHICLE. THE FAILURE MILEAGE WAS 89,000 AND THE CURRENT MILEAGE WAS 90,000. THE PURCHASE DAT…

Read full complaint

TL*THE CONTACT OWNS A 1990 FORD F150. WHEN THE ENGINE SHUT OFF, THE VEHICLE CONTINUED TO RUN. THE DEALER INFORMED THE CONTACT THAT HIS VEHICLE WAS NOT A PART OF RECALL NUMBER 96V071000 (FOR THE IGNITION) AND HE WOULD NOT INSPECT THE VEHICLE. THE FAILURE MILEAGE WAS 89,000 AND THE CURRENT MILEAGE WAS 90,000. THE PURCHASE DATE OF THE VEHICLE WAS UNKNOWN.

NHTSA ODI #10190774

77,000 miles · May 15, 2007
Fuel System, GasolineFire

TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THE VEHICLE IS LEAKING GASOLINE. THE VEHICLE IS EXPERIENCING THE SAME FAILURE AS NOTED IN RECALL #'S 89V141000 (FUEL SYSTEM, GASOLINE:STORAGE:AUXILIARY TANK:SELECTOR DEVICES), # 93V125000 ( FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY), AND # 01I008000 (FUEL SYSTEM, …

Read full complaint

TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THE VEHICLE IS LEAKING GASOLINE. THE VEHICLE IS EXPERIENCING THE SAME FAILURE AS NOTED IN RECALL #'S 89V141000 (FUEL SYSTEM, GASOLINE:STORAGE:AUXILIARY TANK:SELECTOR DEVICES), # 93V125000 ( FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY), AND # 01I008000 (FUEL SYSTEM, GASOLINE). THE MANUFACTURER STATED THAT THE VIN WAS INCLUDED IN THE RECALLS, HOWEVER, HIS VEHICLE WAS UNABLE TO GET REPAIRED FREE OF CHARGE DUE TO THE ELAPSED TIME FRAME. THE ENGINE SIZE WAS UNAVAILABLE. THE CURRENT MILEAGE IS 78,000 AND FAILURE MILEAGE WAS 77,000. UPDATED 06/08/07. *JB

NHTSA ODI #10190760

Official recalls

4

96V071000 · Electrical System:ignition

Apr 25, 1996

THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence & remedy

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)

Jun 1, 1990

UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.

Consequence & remedy

Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.

Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.

89V141000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices

Aug 15, 1989

INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.

Consequence & remedy

Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.

Remedy: REPLACE FUEL LINE ASSEMBLY.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

10

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

EA92029 · Front Seat Back Failure

Opened Aug 27, 1992 · Closed Oct 29, 1993

Status: closed (inferred from source dates) · Seats

There is no summary currently available

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE91064 · Transmission Fluid Fires

Opened Apr 9, 1991 · Closed Jul 5, 1991

Status: closed (inferred from source dates) · Power Train

There is no summary currently available

PE91017 · Ford Truck Inconsistent Vehicle Control.

Opened Nov 27, 1990 · Closed Apr 17, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

SEE CLOSE RESUME