TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WAS SAFETY RECALL # 01I008000, WHICH HAD BEEN EXTENDED 12 YEARS. HOWEVER, THE DEALER AND MANUFACTURER STATED THAT NO RECALL EXISTED. ALL THE CONTACT KNEW WAS THAT THE VEHICLE WAS LEAKING FLUID. THE CURRENT AND FAILURE MILEAGE WERE 120,000. *AK
1990 Ford F150
Owner reports · Recalls · Investigations
Limited comparison data
There is not enough comparable history to draw a useful model-year comparison.
About this comparison →How this year compares
Owner complaints by model year
Compare all F150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 25 of 254 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 129 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 34 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
Fuel System, Gasoline complaints
129 reportsTHE FUEL STARTED TO RUN OUT OF THE FRONT FUEL TANK. I LOST MOST OF THE FUEL OUT OF THE REAR TANK THAT SPILLED ON THE ROAD. I THINK THAT THIS IS A FIRE WAITING TO HAPPEN. NOW I DO NOT USE THE REAR TANK TO STOP THE PROBLEM. I HAVE NOT FIXED THE PROBLEM BECAUSE FORD HAS HAD THIS PROBLEM WITH MANY OF THERE TRUCKS AND THEY SHOULD FI…
Read full complaint
THE FUEL STARTED TO RUN OUT OF THE FRONT FUEL TANK. I LOST MOST OF THE FUEL OUT OF THE REAR TANK THAT SPILLED ON THE ROAD. I THINK THAT THIS IS A FIRE WAITING TO HAPPEN. NOW I DO NOT USE THE REAR TANK TO STOP THE PROBLEM. I HAVE NOT FIXED THE PROBLEM BECAUSE FORD HAS HAD THIS PROBLEM WITH MANY OF THERE TRUCKS AND THEY SHOULD FIX A FUEL PROBLEM. THAT HAS HAPPENED IN MANY OF THERE TRUCKS NO MATTER OF THE MILEAGE OR AGE. *JB
GASOLINE BACK UP AND FLOWING OUT BACK TANK, FROM GAS CAP. *JB
DT: THE CONTACT STATED THAT WHEN FILLING UP THE REAR FUEL TANK IT WOULD PUMP THE GAS INTO THE FRONT TANK. THE GAS OVERFLOWS OUT ONTO THE SIDE OF THE VEHICLE ONCE THE CONSUMER WOULD START TO DRIVE. THE CONTACT NOTICED THIS ON 9-2-05. HE CONTACTED FORD AND THEY SAID THAT THE RECALL O1I008000 HAD EXPIRED. *AK *MR
EVENTS LEADING UP TO EXPLOSION AND FIRE. *JB
I HAVE A 1990 FORD F150 TRUCK. ON 3 DIFFERENT OCCASIONS FUEL FROM THE BACK TANK HAS FLOWED OVER INTO THE FRONT TANK. ON ALL THREE OCCASIONS, I HAVE GONE TO MY TRUCK TO FIND GASOLINE ALL OVER THE GROUND. I STILL HAD TO PUT A BUCKET UNDER THE TANKS FILLERS TO ALLOW THE EXCESS GAS IN THE FRONT TANK TO FLOW DOWN.ON TWO OCCASIONS I H…
Read full complaint
I HAVE A 1990 FORD F150 TRUCK. ON 3 DIFFERENT OCCASIONS FUEL FROM THE BACK TANK HAS FLOWED OVER INTO THE FRONT TANK. ON ALL THREE OCCASIONS, I HAVE GONE TO MY TRUCK TO FIND GASOLINE ALL OVER THE GROUND. I STILL HAD TO PUT A BUCKET UNDER THE TANKS FILLERS TO ALLOW THE EXCESS GAS IN THE FRONT TANK TO FLOW DOWN.ON TWO OCCASIONS I HAD THE TRUCK PARKED IN THE GARAGE. THE GAS THAT FLOWED OUT COVERED ALMOST MY ENTIRE GARAGE FLOOR. ON THE THIRD OCCASION, ENOUGH GAS HAD FLOWED FROM THE TANK TO REACH MY LAWN. IF SOMEONE HAD COME TO MY HOME SMOKING, OR SOME OTHER IGNITION SOURCE WAS TO HAVE COME IN CONTACT WITH IT, MY HOUSE WOULD HAVE BURNED TO THE GROUND. I NOW HAVE TO PARK THE TRUCK OUTSIDE FOR FEAR OF IT CAUSING MY HOUSE TO BURN.
I OWN A 1990 FORD F-150 WITH RECALL # 93S68. THIS IS A CROSS DUAL TANK FUEL CONDITION WHERE THE FRONT TANK OVERLOADS WITH UNUSED FUEL . FRONT TANK IS IN-OPERABLE AND ONLY REAR TANK BEING USED. FRONT TANK CONTINUES TO SPILL FUEL WHEN PARKED AND AFTER 6 YRS OF REPEATED ATTEMPTS IN CONTACT WITH FORD I STILL CAN GET NO RELIEF. I HAV…
Read full complaint
I OWN A 1990 FORD F-150 WITH RECALL # 93S68. THIS IS A CROSS DUAL TANK FUEL CONDITION WHERE THE FRONT TANK OVERLOADS WITH UNUSED FUEL . FRONT TANK IS IN-OPERABLE AND ONLY REAR TANK BEING USED. FRONT TANK CONTINUES TO SPILL FUEL WHEN PARKED AND AFTER 6 YRS OF REPEATED ATTEMPTS IN CONTACT WITH FORD I STILL CAN GET NO RELIEF. I HAVE HAD 2 93S68 RECALLS AND STILL THE TANK LEAKS DANGEROUS GASOLINE EVERYWHERE IT IS PARKED. WHAT AMAZES ME IS HOW FORD HAS BURIED THIS RECALL CONSIDERING WHAT A HAZARD LEAKING FUEL PRESENTS. HAVING OWNED THE TRUCK FOR 10 YRS AND SINCE IT IS IN OTHERWISE PERFECT CONDITION , I AM HOPING AN AGENCY SUCH AS YOURS WOULD HELP ME TO FORCE FORD TO HONOR THIS RECALL UNTIL I AM SATISFIED. PLEASE CONTACT ME AT ANY TIME AT THE 2 PH3'S PROVIDED . THIS IS THE SECOND TIME I HAVE TRIED TO ENLIST THE ASSIST OF NHTSA . *AK
I HAVE DUEL TANKS, OVER THE PAST YEAR THE FUEL MOVED FROM 1 TANK TO THE OTHER TANK. NOW THE FUEL IF LEFT TO FULL. WILL DISCHARGE FROM THE FILLER ON THE OTHER TANK. I COTACTED FORD, AND GOT NO HELP. *AK
CONSUMER STATED THAT HER HUSBAND'S TRUCK WAS LEAKING GAS FROM THE FRONT TANK. THEY TRIED USING ONLY THE BOTTOM TANK, BUT FOUND THAT THE FRONT TANK STILL FILLED UP AND LEAKED. CONSUMER TOOK VEHICLE TO DEALER, WHO TOLD CONSUMER THAT THE PROBLEM WAS THE FUEL PUMP THAT PUMPED GAS FROM ONE TANK TO ANOTHER.*AK *JB
RECALL 93V125000 CONCERNING CHECK VALVE FAILURE. THE VEHICLE HAD DUAL FUEL TANKS, AND WHEN THE REAR TANK WAS IN OPERATION FUEL SPILLED OUT ONTO THE GROUND. THE FUEL WAS EXITING FROM THE FUEL FILLER. CONSUMER'S VEHICLE WAS NOT COVERED UNDER THE RECALL DUE TO VIN. *AK
Official recalls
496V071000 · Electrical System:ignition
Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
89V141000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
10EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA92029 · Front Seat Back Failure
Opened Aug 27, 1992 · Closed Oct 29, 1993
Status: closed (inferred from source dates) · Seats
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
PE91017 · Ford Truck Inconsistent Vehicle Control.
Opened Nov 27, 1990 · Closed Apr 17, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
SEE CLOSE RESUME
Illustration