← New search

1993 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1993 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 81 of 586 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 260 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 77 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 52 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

22 crash reports21 fire reports10 injury reports

What owners actually said

586 reports
Mileage unknown · Apr 27, 2001
Fuel System, Gasoline

DUAL FUEL TANKS HAVE A MALFUNCTIONING CHECK VALVE WHICH ALLOWS FUEL TO FLOW FREELY BETWEEN TANKS. CONSUMER WAS INFORMED THAT THIS VEHICLE WAS NOT INCLUDED IN EITHER FUEL RELATED RECALLS 93V125000 OR 00V424000. *AK *JB

NHTSA ODI #886970

Mileage unknown · Apr 26, 2001
Fuel System, Gasoline

DUAL FUEL TANK SYSTEM IS LEAKING FUEL ONTO EXHAUST PIPE. CONSUMER CONTACTED MANUFACTURER , AND WAS INFORMED HIS VEHICLE WAS NOT INCLUDED IN EITHER NHTSA RECALL 00V424000 OR 93V125000. PLEASE PROVIDE ANY ADDITIONAL INFORMATION/ATTACHMENTS.*AK

NHTSA ODI #886854

Mileage unknown · Apr 26, 2001
Fuel System, Gasoline

FUEL TRANSFER FROM TANK TO TANK, OVERFLOW TO GROUND, LUCKY NO FIRE...YET. *AK

NHTSA ODI #744603

Mileage unknown · Apr 23, 2001
Fuel System, Gasoline

VEHICLE IS SHOWING THE SAME DEFECT AS LISTED IN RECALL CAMPAIGN 00V424000/ FUEL PUMP CHECK VALVE - DUAL FUEL TANK SYSTEM FAILURE. FUEL FROM ONE TANK WILL FLOW INTO OTHER TANK EVERYTIME CONSUMER DRIVES VEHICLE. DEALERSHIP INFORMED CONUMER THAT THERE WAS NO RECALL FOR THIS DEFECT. A PRIVATE MECHANIC GAVE CONSUMER A PRINT O…

Read full complaint

VEHICLE IS SHOWING THE SAME DEFECT AS LISTED IN RECALL CAMPAIGN 00V424000/ FUEL PUMP CHECK VALVE - DUAL FUEL TANK SYSTEM FAILURE. FUEL FROM ONE TANK WILL FLOW INTO OTHER TANK EVERYTIME CONSUMER DRIVES VEHICLE. DEALERSHIP INFORMED CONUMER THAT THERE WAS NO RECALL FOR THIS DEFECT. A PRIVATE MECHANIC GAVE CONSUMER A PRINT OUT REGARDING THE RECALL. *AK SPILLED FUEL COULD RESULT IN A FIRE UNLESS THE PRESSURE REGULATOR IS REPLACED AND REDUNDANT CHECK VALVE IS INSTLLED. *YH

NHTSA ODI #886442

Mileage unknown · Apr 16, 2001
Fuel System, Gasoline

VEHICLE IS SHOWING THE EXACT SYMPTOMS AS DESCRIBED IN RECALL 00V424000. CONSUMER HAD FRONT FUEL PUMP REPLACED LAST MONTH BECAUSE FUEL FROM FRONT TANK WAS BEING TRANSFERRED TO REAR FUEL TANK (DUAL TANK SYSTEM.) ALSO, CONSUMER FILLED FRONT TANK, THEN WENT TO FILL THE REAR TANK, HE WAS SHOWERED WITH FUEL. DEALERSHIP WAS SAYI…

Read full complaint

VEHICLE IS SHOWING THE EXACT SYMPTOMS AS DESCRIBED IN RECALL 00V424000. CONSUMER HAD FRONT FUEL PUMP REPLACED LAST MONTH BECAUSE FUEL FROM FRONT TANK WAS BEING TRANSFERRED TO REAR FUEL TANK (DUAL TANK SYSTEM.) ALSO, CONSUMER FILLED FRONT TANK, THEN WENT TO FILL THE REAR TANK, HE WAS SHOWERED WITH FUEL. DEALERSHIP WAS SAYING THAT THEY WERE UNAWARE OF THIS RECALL SINCE CONSUMER NOTIFICATION WAS SCHEDULED TO BEGIN IN MAY OF 2001, MANUFACTURER AND DEALERSHIP WERE NOT ASSISTING CONSUMER IN ANY WAY TO REPAIR THIS DEFECT. HE HAS NO WAY OF KNOWING WHETHER HE IS INCLUDED IN THE RECALL. PLEASE PROVIDE ANY ADDITIONAL/INFORMATION.*AK

NHTSA ODI #886014

Mileage unknown · Apr 11, 2001
Fuel System, Gasoline

93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS T RETURNED TO SECOND TANK. WHEN THIS OCCURRED, SECOND TANK EXCEEDEDITS LIMIT, CAUSING FUEL SPILLAGE. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER / MANUFACTURER WERE NOTIFIED, AND INFORMED CONSUMER THAT VEHICLE…

Read full complaint

93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS T RETURNED TO SECOND TANK. WHEN THIS OCCURRED, SECOND TANK EXCEEDEDITS LIMIT, CAUSING FUEL SPILLAGE. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER / MANUFACTURER WERE NOTIFIED, AND INFORMED CONSUMER THAT VEHICLE WAS NOT COVERED UNDER A RECALL. PLEASE FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER . *AK

NHTSA ODI #885732

Mileage unknown · Apr 11, 2001
Fuel System, Gasoline

THIS HAS BEEN ADRESSED BY NHTSA /FORD SAYS MY VEHICLE IS NOT COVERED. SEEMS EQUIVALENT TO RECALL NO. OOV424. NO SAFETY DEFECT MENTIONED. *AK

NHTSA ODI #743911

Mileage unknown · Apr 9, 2001
Fuel System, Gasoline

THE FUEL TANK ASSEMBLY FAILED. NLM

NHTSA ODI #560715

Mileage unknown · Apr 6, 2001
Fuel System, GasolineVisibility

DUAL FUEL TANKS WOULD HAVE FUEL OVERFLOWING FROM ONE TANK TO ANOTHER, AND THEN WOULD SPILL OUT. ALSO, WINDSHIELD WIPERS WOULD STOP ON THEIR OWN. WIPER PROBLEM WAS INTERMITTENT.*AK

NHTSA ODI #885306

Mileage unknown · Apr 3, 2001
Suspension

THE SHOCK BRACKETS COLLAPSED AND THE PERSON LOSES CONTROL OVER THE VEHICLE.*AK

NHTSA ODI #743489

Official recalls

7

08V051000 · Vehicle Speed Control:cruise Control

Feb 4, 2008

FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Consequence & remedy

Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

07V336000 · Vehicle Speed Control

Aug 3, 2007

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

00V424000 · Fuel System, Gasoline:storage:tank Assembly

Dec 29, 2000

VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.

Consequence & remedy

Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.

Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).

94V169001 · Parking Brake:conventional

Sep 7, 1994

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence & remedy

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

94V018000 · Structure:body:bumpers

Jan 2, 1994

THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.

Consequence & remedy

Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.

Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

93V089000 · Power Train:transfer Case (4-WHEEL Drive)

May 17, 1993

THE TRANSFER CASES HAVE BEEN BUILT WITH THE WRONG ELECTRIC SHIFT MOTOR. THE TRANSFER CASES CAN SLIP OUT OF THE 4 X 4 HIGH GEAR POSITION DURING COASTING IN FORWARD GEARS OR WITH POWER APPLIED IN REVERSE GEAR.

Consequence & remedy

Consequence: IF THIS OCCURS, THE VEHICLE CAN ROLL FREELY AS IF INNEUTRAL POSITION REGARDLESS OF THE TRANSMISSION GEAR SELECTOR POSITION. THIS CANRESULT IN LOSS OF VEHICLE CONTROL AND AN ACCIDENT.

Remedy: REPLACE DEFECTIVE TRANSFER CASES WITH THE CORRECT VERSION.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.