1993 FORD F-150 4WD FRONT BUMPER CAN OFF, ALL BOLTS MISSING ONLY 1 U-CLIPS PRESENT AND IT IS BROKEN. YESTERDAY (7/22/2010) I HAD TRAVELED TO MY SISTERS HOME, ABOUT 2 MILES FROM MY HOME. ON RETURNING I PARKED MY TRUCK AS USUAL AND WENT INTO MY HOUSE. ABOUT I HOUR LATER AS COMING OUT OF MY HOUSE AND HEADING FOR THE GARAGE, TH…
Read full complaint
1993 FORD F-150 4WD FRONT BUMPER CAN OFF, ALL BOLTS MISSING ONLY 1 U-CLIPS PRESENT AND IT IS BROKEN. YESTERDAY (7/22/2010) I HAD TRAVELED TO MY SISTERS HOME, ABOUT 2 MILES FROM MY HOME. ON RETURNING I PARKED MY TRUCK AS USUAL AND WENT INTO MY HOUSE. ABOUT I HOUR LATER AS COMING OUT OF MY HOUSE AND HEADING FOR THE GARAGE, THAT WAS WHEN I NOTICED THAT THE FRONT BUMPER WAS TILTED DOWN ON THE PASSENGER SIDE. I WENT TO THE FRONT OF THE TRUCK AND WAS ABLE TO LIFT THE FRONT BUMPER UP OFF THE FRAME. IT WAS JUST HANGING ON. I'VE CALLED THE LOCAL FORD DEALER AND THEY TOLD ME THAT IT WAS MY PROBLEM. I DID CHECK THE NHTSA WEB SITE AND FOUND THAT THERE HAD BEEN A RECALL ON MY TRUCK BACK IN 1994 (#94V018000). THIS AFTERNOON I DID CALL THE FORD CUSTOMER CENTER ABOUT THE ISSUE AND THEIR REPLY WAS YES THERE WAS A RECALL FOR THE TRUCK BUT NOT FOR MINE BECAUSE IT WAS MADE AT ANOTHER PLACE. I REALLY DO NOT UNDERSTAND, IT THAT RECALL HAD LIMITATIONS WHY ARE THEY NOT SHOWN ON THE RECALL SUMMARY? THE SAME ISSUE HAPPENED TO MY TRUCK AS THE RECALL SHOWN? THANK YOU, *TR
NHTSA ODI #10344892
Mileage unknown · Feb 8, 2002
Structure
THE RIGHT FRONT SIDE FRAME NEXT TO THE CONTROL ARM BRACKET HAS COMPLETELY RUSTED THROUGH AND BROKEN IN HALF RENDERING THE VEHICLE UNDRIVABLE. I HAVE HAD THE TRUCK TO THE DEALER (NOT THE DEARLER WHERE IT WAS PURCHASED IN 1995) FOR INSPECTION OF THE FRAME AND IT WAS DETERMINED THAT THE FRAME IS VERY THIN AND RUSTED ABOUT A FOOT ON…
Read full complaint
THE RIGHT FRONT SIDE FRAME NEXT TO THE CONTROL ARM BRACKET HAS COMPLETELY RUSTED THROUGH AND BROKEN IN HALF RENDERING THE VEHICLE UNDRIVABLE. I HAVE HAD THE TRUCK TO THE DEALER (NOT THE DEARLER WHERE IT WAS PURCHASED IN 1995) FOR INSPECTION OF THE FRAME AND IT WAS DETERMINED THAT THE FRAME IS VERY THIN AND RUSTED ABOUT A FOOT ON EACH SIDE OF THE BREAK. I HAVE FILED A COMPLAINT WITH FORD AND HAVE TALKED WITH THE SERVICE MANAGER AT PROGRESSIVE FORD TOM BYERS AND ALSO HIS FORD REP NANCY CROWE AND WAS TOLD THAT THE TRUCK WAS TOO OLD AND HAD TOO MANY MILES ON IT AND THEREFOR FORD WOULD NOT REPAIR IT. I EXPRESSED MY CONCERN THAT I FELT THIS WAS A SAFETY ISSUE AS IT INVOLVED THE MAIN STRUCTURE OF THE VEHICLE AND SHOULD NOT HAVE BROKEN AS IT HAS NEVER BEEN INVOLVED IN AN ACCIDENT OR BEEN ABUSED AND WAS TOLD BY NANCY THAT SHE DIDN'T CARE AS THE ORIGINAL FACTORY WARRENTY HAD LONG SINCE EXPIRED. I STATED THAT A TRUCK FRAME SHOULD LAST MORE THAN 9 YEARS WITHOUT DISINTEGRATING AND WAS AGAIN TOLD THERE WOULD BE NO COMPENSATION FROM FORD ON REPAIRS OR REPLACEMENT AND I WAS ALSO TOLD THAT THE TRUCK SHOULD NOT BE DRIVEN. I BELIEVE I AM NOT THE ONLY TRUCK OWNER WITH THIS PROBLEM AS I AM BEING TOLD BY NANCY CROWE.*AK
NHTSA ODI #757972
Mileage unknown · Sep 27, 1999
Structure
THE DRIVER'S SIDE CROSSMEMBER BAR WHICH MEETS THE TWIN BEAM TO FRAME TO WHICH THE MOUNTING BOLTS ARE ATTACHED TO, IS FALLING APART. PLEASE PROVIDE FURTHER INFORMATION AND VIN#. *AK
NHTSA ODI #848727
Mileage unknown · Jun 29, 1998
Structure
LEFT FRAME RAIL CRACKED AND BROKEN BEHIND FRONT AXLE.
NHTSA ODI #537216
Mileage unknown · Nov 12, 1997
Structure
THE POWER LOCKS RUSTED AND STOPPED WORKING. THE DEALER REPLACED THE POWER LOCKS. *AK CONSUMER STATES THERE WAS A PIECE OF LEATHER WITH THREE STAPLES THAT COVERED THE LOCKING GEAR MECHANISM, THE STAPLES CAME LOOSE EXPOSING THE MECHANISM. *SLC
NHTSA ODI #818851
Mileage unknown · Feb 12, 1997
Engine And Engine CoolingFuel System, GasolineParking BrakeFire
VEHICLE FIRE.
NHTSA ODI #514761
Mileage unknown · May 28, 1996
Structure
BOTH DRIVER AND PASSENGER SIDE DOOR HINGES ARE CRACKED. *AK
NHTSA ODI #984915
Mileage unknown · Jul 19, 1995
Electrical SystemPower TrainSeats
STEERING WHEEL IS OFF CENTER. *DH
NHTSA ODI #484230
Mileage unknown · Jul 5, 1995
Structure
THE TAIL GATE ON VEHICLE IS VERY EASY TO REMOVE, COULD CAUSE TO COME OFF WHEN DRIVING. TT
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Consequence & remedy
Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.
Consequence & remedy
Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.
Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.
Consequence & remedy
Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.
Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
THE TRANSFER CASES HAVE BEEN BUILT WITH THE WRONG ELECTRIC SHIFT MOTOR. THE TRANSFER CASES CAN SLIP OUT OF THE 4 X 4 HIGH GEAR POSITION DURING COASTING IN FORWARD GEARS OR WITH POWER APPLIED IN REVERSE GEAR.
Consequence & remedy
Consequence: IF THIS OCCURS, THE VEHICLE CAN ROLL FREELY AS IF INNEUTRAL POSITION REGARDLESS OF THE TRANSMISSION GEAR SELECTOR POSITION. THIS CANRESULT IN LOSS OF VEHICLE CONTROL AND AN ACCIDENT.
Remedy: REPLACE DEFECTIVE TRANSFER CASES WITH THE CORRECT VERSION.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2
EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
1993 Ford F-150 Problems, Complaints & Recalls | Skip That Year