← New search

1993 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1993 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 81 of 586 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 260 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 77 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 52 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

22 crash reports21 fire reports10 injury reports

Fuel System, Gasoline complaints

260 reports
Clear category filter
148,000 miles · May 17, 2007
Fuel System, Gasoline

TL*THE CONTACT OWNS A 1993 FORD F150. THE VEHICLE IS EQUIPPED WITH A DUAL FUEL TANK, BUT ONLY ONE IS ACCEPTING FUEL. THE FAILURE IS CAUSING FUEL TO SPILL. THE CONTACT REFERENCED RECALL # 01I008000 (FUEL SYSTEM, GASOLINE). THE CURRENT MILEAGE IS 156,000 AND FAILURE MILEAGE WAS 148,000. THE CONSUMER STATED BOTH TANKS TAKE FUE…

Read full complaint

TL*THE CONTACT OWNS A 1993 FORD F150. THE VEHICLE IS EQUIPPED WITH A DUAL FUEL TANK, BUT ONLY ONE IS ACCEPTING FUEL. THE FAILURE IS CAUSING FUEL TO SPILL. THE CONTACT REFERENCED RECALL # 01I008000 (FUEL SYSTEM, GASOLINE). THE CURRENT MILEAGE IS 156,000 AND FAILURE MILEAGE WAS 148,000. THE CONSUMER STATED BOTH TANKS TAKE FUEL, THERE IS A CROSS FLOW CONDITION. THE FAILURE IS CAUSING FUEL TO SPILL THROUGH THE FILLER CAP. UPDATED 07/06/07 *TR

NHTSA ODI #10191059

56,000 miles · May 4, 2007
Fuel System, GasolineInjury

(1) FILLED FUEL TANKS WITH GAS (2) FUEL BEGAN PUSHING OUT OF THE REAR FILLER CAP AFTER A FEW MINUTES OF DRIVING. NOTIFIED BY ANOTHER DRIVER AND PULLED OVER. OPENED THE FUEL DOOR COVER AND SAW GAS SPILLING OUT AROUND THE CAP. TOOK THE CAP OFF AND FUEL BLEW OUT AT ME. MYSELF AND MY DAUGHTER HAD GASOLINE ALL OVER US. (3) TOO…

Read full complaint

(1) FILLED FUEL TANKS WITH GAS (2) FUEL BEGAN PUSHING OUT OF THE REAR FILLER CAP AFTER A FEW MINUTES OF DRIVING. NOTIFIED BY ANOTHER DRIVER AND PULLED OVER. OPENED THE FUEL DOOR COVER AND SAW GAS SPILLING OUT AROUND THE CAP. TOOK THE CAP OFF AND FUEL BLEW OUT AT ME. MYSELF AND MY DAUGHTER HAD GASOLINE ALL OVER US. (3) TOOK IT TO THE DEALER AND WAS INFORMED IT WAS A KNOWN DEFECT AND THE RECALLED PART HAD BEEN REPLACED WITH REDESIGNED FUEL PUMP IN 2001. NEW REDESIGN IS NOW DOING THE SAME THING. CONTACTED FORD CUSTOMER SERVICE MAY 3, 2007, WAS TOLD INITIALLY BY 'SUE' THAT FORD WOULD PARTICIPATE AND REPAIR THE VEHICLE. THEN A SUPERVISOR, ID# 1157 (SHIRA) THAT IT WAS ALREADY FIXED 28 DEC 01 AND THEY WON'T FIX IT AGAIN ALTHOUGH IT'S A KNOWN PROBLEM. *TR

NHTSA ODI #10189741

235,000 miles · Jun 27, 2006
Fuel System, Gasoline

DT*: THE CONTACT STATED THERE ARE PROBLEMS WITH VEHICLE'S FUEL INTAKE. EVERY TIME FUEL WAS INJECTED INTO THE VEHICLE THE FILLER CAP WOULD OVERFLOW. THE DEALER WAS CONTACTED AND DETERMINED THAT THE VEHICLE HAD THE SAME CHARACTERISTICS OF A RECALL. THE CAPACITY OF THE RECEIVING TANK EXCEEDED INTAKE AND CAUSED AN OVERFLOW FROM FIL…

Read full complaint

DT*: THE CONTACT STATED THERE ARE PROBLEMS WITH VEHICLE'S FUEL INTAKE. EVERY TIME FUEL WAS INJECTED INTO THE VEHICLE THE FILLER CAP WOULD OVERFLOW. THE DEALER WAS CONTACTED AND DETERMINED THAT THE VEHICLE HAD THE SAME CHARACTERISTICS OF A RECALL. THE CAPACITY OF THE RECEIVING TANK EXCEEDED INTAKE AND CAUSED AN OVERFLOW FROM FILLER CAP. THE FUEL SEEPING COULD RESULT IN FIRE. HOWEVER THE VIN WAS NOT INCLUDED IN THE RECALL. THEREFORE ANY SERVICE WOULD INCUR A CHARGE.

NHTSA ODI #10160851

192,700 miles · Jun 26, 2006
Fuel System, Gasoline

DT*: THE CONTACT STATED THAT WHILE DRIVING AT 45 MPH, THERE WAS AN ODOR OF GASOLINE COMING FROM THE VEHICLE. THE CONTACT WAS MOTIONED TO PULL OVER BY ANOTHER MOTORIST, AND WHEN THE CONTACT EXITED THE VEHICLE AND EXAMINED BOTH TANKS, THE FRONT TANK WAS OVERFLOWING GASOLINE. THE VEHICLE WAS EXAMINED BY AN INDEPENDENT REPAIR SHO…

Read full complaint

DT*: THE CONTACT STATED THAT WHILE DRIVING AT 45 MPH, THERE WAS AN ODOR OF GASOLINE COMING FROM THE VEHICLE. THE CONTACT WAS MOTIONED TO PULL OVER BY ANOTHER MOTORIST, AND WHEN THE CONTACT EXITED THE VEHICLE AND EXAMINED BOTH TANKS, THE FRONT TANK WAS OVERFLOWING GASOLINE. THE VEHICLE WAS EXAMINED BY AN INDEPENDENT REPAIR SHOP, WHERE IT WAS DETERMINED THAT THERE WAS A PROBLEM WITH THE FUEL REGULATOR. THERE IS A NHTSA RECALL # 93V125000. THE VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO THE VIN.

NHTSA ODI #10160732

258,000 miles · Apr 29, 2006
Fuel System, Gasoline

1. ONE MORNING I STARTED MY VEHICLE AND IT WOULD NOT START ON THE FRONT TANK SO I BEGAN TO USE THE REAR TANK ONLY. 2. VERY SOON THEREAFTER, GASOLINE BEGAN POURING OUT OF THE FRONT TANK FILLER CAP. IT'S TOO DANGEROUS TO DRIVE, WHATEVER GAS GETS PUT INTO THE REAR TANK IS PUMPED INTO THE FRONT TANK WHILE BEING DRIVEN AND GAS SPILLS…

Read full complaint

1. ONE MORNING I STARTED MY VEHICLE AND IT WOULD NOT START ON THE FRONT TANK SO I BEGAN TO USE THE REAR TANK ONLY. 2. VERY SOON THEREAFTER, GASOLINE BEGAN POURING OUT OF THE FRONT TANK FILLER CAP. IT'S TOO DANGEROUS TO DRIVE, WHATEVER GAS GETS PUT INTO THE REAR TANK IS PUMPED INTO THE FRONT TANK WHILE BEING DRIVEN AND GAS SPILLS OUT OF CAP GOING DOWN THE ROAD. 3. NOTHING HAS BEEN CORRECTED YET, I'M TRYING TO GET LOCAL FORD DEALER TO FIX IT BUT THEY SAY THERE IS NO RECALL FOR MY VIN. *JB

NHTSA ODI #10156436

150,000 miles · Apr 22, 2006
Fuel System, Gasoline

I HAVE FOUND A PROBLEM WITH MY VEHICLE WHICH IS, ACCORDING TO NHTSA CAMPAIGN NUMBER 93V125000, RECALLED FOR A SAFETY PURPOSE. A MALFUNCTIONING CHECK VALVE IN THE FUEL PUMP ASSEMBLY CAUSES FUEL TO RETURN TO THE SECOND TANK AND OVERFLOW. THERE IS A GREAT CHANCE FOR A FIRE BECAUSE OF THE FUEL OVERAGE. HOWEVER, FORD DOES NOT RECOGN…

Read full complaint

I HAVE FOUND A PROBLEM WITH MY VEHICLE WHICH IS, ACCORDING TO NHTSA CAMPAIGN NUMBER 93V125000, RECALLED FOR A SAFETY PURPOSE. A MALFUNCTIONING CHECK VALVE IN THE FUEL PUMP ASSEMBLY CAUSES FUEL TO RETURN TO THE SECOND TANK AND OVERFLOW. THERE IS A GREAT CHANCE FOR A FIRE BECAUSE OF THE FUEL OVERAGE. HOWEVER, FORD DOES NOT RECOGNIZE THIS AS A RECALL ON MY VEHICLE, BASED SOLELY ON MY VEHICLE IDENTIFICATION NUMBER. *JB

NHTSA ODI #10155868

87,066 miles · Feb 21, 2006
Fuel System, Gasoline

A FUEL SYSTEM PARTS FAILURE RESULTED IN THE TRANSFER OF GASOLINE FROM ONE TANK TO THE OTHER. I BECAME AWARE OF THE PROBLEM WHEN I SAW FUEL RUNNING ONTO THE PAVEMENT UNDER THE VEHICLE. *NM

NHTSA ODI #10150786

87,560 miles · Jan 31, 2006
Fuel System, Gasoline

DT*: THE CONTACT STATED THERE WAS A RECALL ON THE VEHICLE, NHTSA CAMPAIGN ID # 93V125000 CONCERNING THE FUEL SYSTEM. THIS WAS COMPLETED ACCORDINGLY AS INDICATED IN THE RECALL. HOWEVER, THE RECALL DID NOT CORRECT THE PROBLEM. THE CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES UNUSED FUEL FROM ONE TANK TO RECIRCULATE TO THE S…

Read full complaint

DT*: THE CONTACT STATED THERE WAS A RECALL ON THE VEHICLE, NHTSA CAMPAIGN ID # 93V125000 CONCERNING THE FUEL SYSTEM. THIS WAS COMPLETED ACCORDINGLY AS INDICATED IN THE RECALL. HOWEVER, THE RECALL DID NOT CORRECT THE PROBLEM. THE CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES UNUSED FUEL FROM ONE TANK TO RECIRCULATE TO THE SECONDARY TANK WHICH RESULTS IN FUEL SPILLAGE FROM THE FILLER NECK. ALTHOUGH THE VEHICLE WAS SEEN BY AN INDEPENDENT REPAIR SHOP, NO REPAIRS WERE MADE.

NHTSA ODI #10149091

45,000 miles · Oct 10, 2005
Fuel System, Gasoline

THE FRONT GAS TANK ON MY DUAL TANK 93 F150 STARTED LEAKING. I FOUND THAT THERE IS A PLASTIC COVER ON THE FRONT OF THE TANK THAT COLLECTS DIRT AND DEBRIS. THE COLLECTION OF THIS DIRT AND DEBRIS BETWEEN THE PLASTIC COVER AND TANK CAUSED THE TANK TO RUST IN THE LOCATION. A LEAK DEVELOPED. GAS LEAKING ON THE GROUND IS NOT A GOOD…

Read full complaint

THE FRONT GAS TANK ON MY DUAL TANK 93 F150 STARTED LEAKING. I FOUND THAT THERE IS A PLASTIC COVER ON THE FRONT OF THE TANK THAT COLLECTS DIRT AND DEBRIS. THE COLLECTION OF THIS DIRT AND DEBRIS BETWEEN THE PLASTIC COVER AND TANK CAUSED THE TANK TO RUST IN THE LOCATION. A LEAK DEVELOPED. GAS LEAKING ON THE GROUND IS NOT A GOOD THING. MY REMEDY SO FAR HAS BEEN TO NOT USE THE FRONT TANK. THE TANK IS STILL ON THE TRUCK AND NOW HAS THE PLASTIC COVER REMOVED. I REMOVED IT TO FIND WHERE THE LEAK WAS COMING FROM. THIS APPEARS TO BE A COMMON PROBLEM SINCE THE TANKS ARE EASILY AVAILABLE ON E-BAY ALL THE TIME. *JB

NHTSA ODI #10139200

88,000 miles · Jun 21, 2005
Fuel System, Gasoline

1993 FORD F-150 2WD PICKUP WITH DUAL TANKS. ONE TANK OVERFLOWED PRESSURIZED GAS ON 19 JUNE 2005. NOTICED RECALL 01M05. THIS VEHICLE IS COVERED UNDER THIS RECALL, BUT 12 YEARS OR 150,000 MILES. THE CAR IS 13 DAYS OUT OF THE RECALL TIMEFRAME, AND FORD WILL NOT COVER THIS RECALL. THEY WON'T EVEN CONSIDER A PARTIAL GOOD WILL ADJ…

Read full complaint

1993 FORD F-150 2WD PICKUP WITH DUAL TANKS. ONE TANK OVERFLOWED PRESSURIZED GAS ON 19 JUNE 2005. NOTICED RECALL 01M05. THIS VEHICLE IS COVERED UNDER THIS RECALL, BUT 12 YEARS OR 150,000 MILES. THE CAR IS 13 DAYS OUT OF THE RECALL TIMEFRAME, AND FORD WILL NOT COVER THIS RECALL. THEY WON'T EVEN CONSIDER A PARTIAL GOOD WILL ADJUSTMENT.

NHTSA ODI #10126074

Official recalls

7

08V051000 · Vehicle Speed Control:cruise Control

Feb 4, 2008

FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Consequence & remedy

Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

07V336000 · Vehicle Speed Control

Aug 3, 2007

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

00V424000 · Fuel System, Gasoline:storage:tank Assembly

Dec 29, 2000

VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.

Consequence & remedy

Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.

Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).

94V169001 · Parking Brake:conventional

Sep 7, 1994

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence & remedy

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

94V018000 · Structure:body:bumpers

Jan 2, 1994

THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.

Consequence & remedy

Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.

Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

93V089000 · Power Train:transfer Case (4-WHEEL Drive)

May 17, 1993

THE TRANSFER CASES HAVE BEEN BUILT WITH THE WRONG ELECTRIC SHIFT MOTOR. THE TRANSFER CASES CAN SLIP OUT OF THE 4 X 4 HIGH GEAR POSITION DURING COASTING IN FORWARD GEARS OR WITH POWER APPLIED IN REVERSE GEAR.

Consequence & remedy

Consequence: IF THIS OCCURS, THE VEHICLE CAN ROLL FREELY AS IF INNEUTRAL POSITION REGARDLESS OF THE TRANSMISSION GEAR SELECTOR POSITION. THIS CANRESULT IN LOSS OF VEHICLE CONTROL AND AN ACCIDENT.

Remedy: REPLACE DEFECTIVE TRANSFER CASES WITH THE CORRECT VERSION.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.