NO SUMMARY LISTED FOR ABOVE VEHICLE. *AK
1993 Ford F-150
Owner reports · Recalls · Investigations
Similar to other model years
Owner complaints for the 1993 Ford F-150 do not stand out strongly from the model-year median of 676.
About this comparison →How this year compares
Owner complaints by model year
Compare all F-150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 81 of 586 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 260 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Service Brakes, Hydraulic. Review the 77 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 52 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
Fuel System, Gasoline complaints
260 reportsNHTSA RECALL 93V125000/FUEL TANK ASSEMBLY: VEHICLE EXPERIENCED SAME PROBLEM AS IN RECALL; DEALER NOTIFIED, AND INFORMED CONSUMER THAT VEHICLE WAS NOT PART OF RECALL DUE TO VIN. *AK
THE PROBLEM CONSISTS OF GAS BEING PUMPED FROM THE BACK TANK TO THE FRONT ON A DUAL TANK SYSTEM. THIS ITEM WAS A RECALL ITEM, AND WHEN MY TRUCK WAS IN FOR SERVICE FOR OTHER WORK AT COX FORD IN HAMPSTEAD MD THEY INDICATED THAT THEY PERFORMED THE RECALL REPAIR ON THE FUEL SYSTEM FOR THIS EXACT PROBLEM, THOUGH I WAS HAVING NO TROUBL…
Read full complaint
THE PROBLEM CONSISTS OF GAS BEING PUMPED FROM THE BACK TANK TO THE FRONT ON A DUAL TANK SYSTEM. THIS ITEM WAS A RECALL ITEM, AND WHEN MY TRUCK WAS IN FOR SERVICE FOR OTHER WORK AT COX FORD IN HAMPSTEAD MD THEY INDICATED THAT THEY PERFORMED THE RECALL REPAIR ON THE FUEL SYSTEM FOR THIS EXACT PROBLEM, THOUGH I WAS HAVING NO TROUBLE WITH THE FUEL TANK ASSEMBLY AT THAT TIME. ABOUT A YEAR AND A HALF LATER I NOTICED THAT AFTER I EXHAUSTED THE FRONT TANK AND SWITCHED TO THE REAR TANK, ONCE THE REAR TANK WAS EXHAUSTED I NOTICED THAT THE FRONT TANK WOULD THEN HAVE AS MUCH AS 1/3 TANK OF FUEL IN IT. I DECIDED TO LIVE WITH THE PROBLEM FOR THE TIME BEING, BUT APPROACHED THE DEALER ABOUT THIS DURING APRIL 1999 AND THE DEALER INFORMED ME THAT SINCE THE RECALL REPAIR HAD BEEN PREVIOUSLY DONE AND THE REPAIR WARRANTY HAD EXPIRED, ANY SUBSEQUENT REPAIRS WOULD BE MY RESPONSIBILITY. NEEDLESS TO SAY I AM NOT VERY HAPPY WITH FORD'S HANDLING OF THIS PROBLEM. THE PROBLEM COMPOROMISES MY VEHICLE'S SAFETY AND RESALE VALUE, AND I HAVE TO BE CAREFUL NOT TO ACCIDENTALLY PUMP MY REAR TANK BEFORE THE FRONT IS EMPTY. *AK
RECALL 93V125000, DEFECTIVE FUEL CHECK VALVE CAUSING FUEL TO GO FROM ONE TANK TO ANOTHER TANK, AND MAY CAUSE SPILLAGE OF THE FUEL WHICH MAY RESULT IN A FIRE. THERE IS A RECALL FOR MAKE/MODEL. BUT THIS VEHICLE IS NOT INCLUDED IN THE RECALL DUE TO VIN ALTHOUGH IT HAS THE SAME PROBLEM. PLEASE PROVIDE FURTHER INFORMATION. *AK
THIS VEHICLE HAS THE DOUBLE FUEL TANKS,.THE SWITCH IS FAULTY, AND IT CAUSES THE FUEL FROM THE SECOND TANK TO BE PUMPED BACK INTO THE FIRST TANK, RESULTING IN THE TANK OVERFLOWING. DEALER HAS BEEN CONTACTED, AND THEY TOLD CONSUMER THAT IT WILL COAST $800.00 TO REPAIR. *AK
VEHICLE HAS DUAL FUEL TANKS. ONE TANK WAS DUMPING FUEL INTO OTHER TANK TANK & CAUSED AN OVERFLOW & WOULD SPILL. CONTACTED MANUFACTURER AFTER BEING INFORMED BY A FRIEND THAT THERE WAS A RECALL ON DUAL TANKS MANUFACTURER. INFORMED CONSUMER THAT THERE WASNO RECALL ON VEHICLE & WILL NOT FIX DUAL FUEL TANK PROBLEM. *AK
A PORTION OF UNUSED FUEL FROM ONE TANK IS RETURNING TO THE SECOND TANK,CAUSING SPILLAGE. A RECALL HAS BEEN ISSUED ON THE VEHICLE'S MAKE/MODEL. HOWEVER THIS VEHICLE WAS NOT INCLUDED DUE TO VIN. DEALER HAS INSPECTED THE VEHICLE . MANUFACTURER HAS BEEN NOTIFIED. *AK
GAS WAS SPRAYING OUT OF GAS INSERTION POINT ON SIDE OF TRUCK FROM FRONT TANK. THE TRUCK HAS BEEN PREVIOUSLY REPAIRED UNDER RECALL IN APPROX. 1994. CONTACTED LOCAL FORD DEALER, THEY WERE AWARE OF PRIOR INSTANCES WHERE THIS HAS OCCURED AND THE CAUSE OF THIS PROBLEM. BOTH TANKS WERE RECENTLY FILLED FOR THIS TO OCCUR. GAS FROM ONE …
Read full complaint
GAS WAS SPRAYING OUT OF GAS INSERTION POINT ON SIDE OF TRUCK FROM FRONT TANK. THE TRUCK HAS BEEN PREVIOUSLY REPAIRED UNDER RECALL IN APPROX. 1994. CONTACTED LOCAL FORD DEALER, THEY WERE AWARE OF PRIOR INSTANCES WHERE THIS HAS OCCURED AND THE CAUSE OF THIS PROBLEM. BOTH TANKS WERE RECENTLY FILLED FOR THIS TO OCCUR. GAS FROM ONE TANK IS BEING PUMPED INTO THE OTHER TANK FROM THE RETURN GAS SUPPLY BY A LEAK IN THE CHECK VALVES. THIS PROBLEM HAS BROUGHT ABOUT MANY SAFETY ISSUES ONE BEING A FIRE HAZARD. FORD MOTOR COMPANY IS UNWILLING TO DO ANYTHING TO REMEDY THIS SITUATION. FORD'S ONLY RESPONSE IS THAT THE RECALL HAS EXPIRED. IT IS MY ASSUMPTION THAT FORD'S DESIGN OF THE DUAL TANK SYSTEM WAS INFERIOR OR THAT INFERIOIR PARTS ARE BEING USED. THIS IS PUTTING MY FAMILY AND OTHER FAMILIES IN JEOPARDY.
TRUCK HAS DUAL GAS TANKS. IF ONE TANK IS FULL, AND CONSUMER SWITCHES TO SECOND TANK, IT CAUSES ONE TANK TO OVERFLO, WHICH COULD LEAD TO A FIRE. *AK
WHEN CONSUMER FILLS UP DUAL GAS TANKS, THE SECOND TANK OVERFLOWS AND THE GAS SPILLS INTO THE STREET. THIS IS A SAFETY CONCERN . *AK
Official recalls
708V051000 · Vehicle Speed Control:cruise Control
Feb 4, 2008
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Consequence & remedy
Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
07V336000 · Vehicle Speed Control
Aug 3, 2007
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
00V424000 · Fuel System, Gasoline:storage:tank Assembly
Dec 29, 2000
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.
Consequence & remedy
Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.
Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).
94V169001 · Parking Brake:conventional
Sep 7, 1994
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
94V018000 · Structure:body:bumpers
Jan 2, 1994
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.
Consequence & remedy
Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.
Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
93V089000 · Power Train:transfer Case (4-WHEEL Drive)
May 17, 1993
THE TRANSFER CASES HAVE BEEN BUILT WITH THE WRONG ELECTRIC SHIFT MOTOR. THE TRANSFER CASES CAN SLIP OUT OF THE 4 X 4 HIGH GEAR POSITION DURING COASTING IN FORWARD GEARS OR WITH POWER APPLIED IN REVERSE GEAR.
Consequence & remedy
Consequence: IF THIS OCCURS, THE VEHICLE CAN ROLL FREELY AS IF INNEUTRAL POSITION REGARDLESS OF THE TRANSMISSION GEAR SELECTOR POSITION. THIS CANRESULT IN LOSS OF VEHICLE CONTROL AND AN ACCIDENT.
Remedy: REPLACE DEFECTIVE TRANSFER CASES WITH THE CORRECT VERSION.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.