Electrical System. Review the 19 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Engine And Engine Cooling. Review the 9 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Structure. Review the 6 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
2 crash reports18 fire reports2 injury reports
What owners actually said
45 reports
Mileage unknown · Aug 4, 2008
Engine And Engine CoolingFire
I AM WRITING YOU TODAY ABOUT A SITUATION THAT OCCURRED JULY 3RD 1986 IN MORTON GROVE ILLINOIS AT 11:52P.M. I AM THE MOTHER OF A 2 YEAR OLD THAT WAS BURNED TO DEATH IN A 1986 FORD ESCORT THAT WAS NOT ON IN THE PARKING LOT OF A GROCERY STORE. YES IT HAS BEEN OVER 20 YEARS, BUT DURING THE COURSE OF THIS TIME I HAVE NOT BEEN ABLE T…
Read full complaint
I AM WRITING YOU TODAY ABOUT A SITUATION THAT OCCURRED JULY 3RD 1986 IN MORTON GROVE ILLINOIS AT 11:52P.M. I AM THE MOTHER OF A 2 YEAR OLD THAT WAS BURNED TO DEATH IN A 1986 FORD ESCORT THAT WAS NOT ON IN THE PARKING LOT OF A GROCERY STORE. YES IT HAS BEEN OVER 20 YEARS, BUT DURING THE COURSE OF THIS TIME I HAVE NOT BEEN ABLE TO GET ANYONE TO LISTEN TO MY STORY. WELL, THIS PARTICULAR CAR WAS A RENTAL FROM BUDGET RENTAL IN GLENVIEW ILLINOIS AND WE WERE ON A FAMILY OUTING. ALL WAS WELL AND THEN WE STOPPED OFF TO GET SOME FIRE WORKS. I COULD ONLY AFFORD SMOKE BOMBS AND SPARKLES. NEEDLESS TO SAY WHEN THIS HORRIFIC EVENT OCCURRED THE FIRE DEPARTMENT STATED THAT THIS WAS THE REASON THE CAR CAUGHT ON FIRE. THAT IS NOT TRUE. YOU CAN'T START A FIREWORK WITHOUT A LIGHTER. THE RENTAL CAR DID NOT HAVE A CIGARETTE LIGHTER OR THERE WERE NO MATCHES. I FOUND A NEWS ARTICLE DATE IN THE VIRGINIAN PILOT, APRIL 18, 1996, TEN YEARS LATER STATING THAT THERE WAS AN IGNITION PROBLEM IN CARS DATED AS FAR BACK AS 1984. PLEASE FOR THE LAST 20 YEARS I HAVE HAD TO LIVE WITH THIS MINI MOVIE PLAYING IN MY HEAD OVER AND OVER AGAIN WITH NO RESOLUTION. THIS IS NOT ABOUT MONEY OR FAME. MY CHILD DIED BEFORE HE COULD SEE WHAT LIFE IS LIKE WITH HIS FAMILY. HERE IS A COPY OF THE ARTICLE. I NEED HELP. THIS INCIDENT HAS CRUSHED MY FAMILY. MY OLDEST SON AND I HAD TO WITNESS THIS UNABLE TO HELP MY BABY. YOU WONDER WHY IT TOOK ME SO LONG TO WRITE THIS LETTER, IT IS VERY HARD FOR ME TO DO THIS NOW. I NEED CLOSURE. EVERY YEAR ON THIS DATE, I SIT AT HIS GRAVE SITE AND WONDER WHAT WENT WRONG. I RENT CARS ALL THE TIME AND I AM IN FEAR OF ANYTHING CAN HAPPEN. BUT IT WAS STATED THAT THERE WAS A KNOWN FACT OF A PROBLEM. ALTHOUGH ACKNOWLEDGED 10 YEARS LATER, BETTER LATE THAN NEVER. YOUR COMPANY HAS IMPROVED DURING TRIAL AND ERROR, HOWEVER, DID MY SON HAVE TO DIE DURING THE ERROR PART. *TR
NHTSA ODI #10236821
Mileage unknown · Apr 20, 2004
Engine And Engine Cooling
CONSUMER BECAME ILL FROM THE FUMES THAT EMITTED FROM THE HEATER/AC SYSTEM. *PH THE VEHICLE WAS RECALLED FOR THE HEATER/RADIATOR SYSTEM HOWEVER THE CONSUMER REMAINED ILL. *NM
NHTSA ODI #10068586
Mileage unknown · Jun 4, 2002
Electrical System
WHILE DRIVING AT 45MPH VEHICLE SHUTS OFF WITH NO WARNING. CONSUMER IS UNABLE TO GET IT STARTED. CAUSE UNKNOWN. DEALER NOTIFIED.*AK
NHTSA ODI #8011043
Mileage unknown · Aug 17, 2001
Unknown Or Other
WHILE TRAVELING NOTICED THAT ENGINE INDICATOR LIGHT WOULD FLASH ON AND STAY ON THROUGH OUT TRAVEL .DEALER HAS BEEN CONTACTED, TECHNICIAN CUT INDICATION LIGHT OFF 4 TIME WITH COST TO CUSTOMER. PLEASE PROVIDE FURTHER INFORMATION.*AK
NHTSA ODI #894595
Mileage unknown · Oct 15, 2000
Unknown Or Other
NO SUMMARY
NHTSA ODI #734369
Mileage unknown · Oct 14, 2000
Electrical System
SEVERAL TIMES OVER THE LAST FEW MONTHS WHILE DRIVING WITH THE ENGINE TEMPERATURE IN THE NORMAL RANGE ON THE FREEWAY TRAVELING AT BETWEEN 70-75 MPH THE VEHICLE STALLS AND WILL NOT RESTART. WHEN PULLED TO THE SIDE OF THE ROAD AFTER LOOKING UNDER THE HOOD AND REMOVING THE TIMING PLUG AND ALLOWING THE IGNITION MODULE TO COOL FOR AB…
Read full complaint
SEVERAL TIMES OVER THE LAST FEW MONTHS WHILE DRIVING WITH THE ENGINE TEMPERATURE IN THE NORMAL RANGE ON THE FREEWAY TRAVELING AT BETWEEN 70-75 MPH THE VEHICLE STALLS AND WILL NOT RESTART. WHEN PULLED TO THE SIDE OF THE ROAD AFTER LOOKING UNDER THE HOOD AND REMOVING THE TIMING PLUG AND ALLOWING THE IGNITION MODULE TO COOL FOR ABOUT 5 MINUTES THE ENGINE RESTARTS. THE ENGINE WILL NOT RESTART WITHOUT REMOVING THE TIMING PLUG. I HAVE REPLACED THE IGNITION MODULE AND THE IGNITION MODULE PICKUP WITH ORIGINAL FACTORY REPLACEMENT PARTS. THE PROBLEM GOES AWAY FOR A SHORT PERIOD OF TIME AND THEN RESURFACES AFTER ABOUT A FEW WEEKS AFTER REPLACEMENT. A CALIFORNA JUDGE HAS ORDERED A RECALL TO REPAIR THIS PROBLEM HOWEVER FORD MOTOR COMPANY WILL NOT COMPLY UNLESS THE NHTSA ORDERS THEM TO DO SO. I WILL CONTINUE TO REPLACE THE PARTS AS TO NOT ENDANGER MYSELF OR OTHERS ON THE FREEWAY. THANK YOU FOR YOUR CONSIDERATION
NHTSA ODI #734328
80,150 miles · Oct 14, 2000
Electrical System
SEVERAL TIMES OVER THE LAST FEW MONTHS WHILE DRIVING WITH THE ENGINE TEMPERATURE IN THE NORMAL RANGE ON THE FREEWAY TRAVELING AT BETWEEN 70-75 MPH THE ENGINE STALLS AND WILL NOT RESTART. WHEN PULLED TO THE SIDE OF THE ROAD AFTER LOOKING UNDER THE HOOD AND REMOVING THE TIMING PLUG AND ALLOWING THE IGNITION MODULE TO COOL FOR ABO…
Read full complaint
SEVERAL TIMES OVER THE LAST FEW MONTHS WHILE DRIVING WITH THE ENGINE TEMPERATURE IN THE NORMAL RANGE ON THE FREEWAY TRAVELING AT BETWEEN 70-75 MPH THE ENGINE STALLS AND WILL NOT RESTART. WHEN PULLED TO THE SIDE OF THE ROAD AFTER LOOKING UNDER THE HOOD AND REMOVING THE TIMING PLUG AND ALLOWING THE IGNITION MODULE TO COOL FOR ABOUT 5 MINUTES THE ENGINE RESTARTS. THE ENGINE WILL NOT RESTART WITHOUT REMOVING THE TIMING PLUG. I HAVE REPLACED THE IGNITION MODULE AND THE IGNITION MODULE PICKUP WITH ORIGINAL FACTORY REPLACEMENT PARTS. THE PROBLEM GOES AWAY FOR A SHORT PERIOD OF TIME AND THEN RESURFACES AFTER ABOUT A FEW WEEKS AFTER REPLACEMENT. A CALIFORNIA JUDGE HAS ORDERED A RECALL TO REPAIR THIS PROBLEM HOWEVER FORD MOTOR COMPANY WILL NOT COMPLY UNLESS THE NHTSA ORDERS THEM TO DO SO. I WILL CONTINUE TO REPLACE THE PARTS AS TO NOT ENDANGER MYSELF OR OTHERS ON THE FREEWAY. THANK YOU FOR YOUR CONSIDERATION. *AK *NLM **DIMSII IVOQ ENTRY POSTED AFTER 12/12/02 CUT-OVER TO ARTEMIS*734328
NHTSA ODI #10007035
Mileage unknown · Oct 12, 2000
Electrical System
IGNITION MODULE HAS BEEN REPLACED TWICE IN 3 YEARS, CAR WAS STALLING AT LOW SPEED. THE SAME PROBLEM SEEMS TO BE RETURNING.
NHTSA ODI #734155
Mileage unknown · Oct 11, 2000
Electrical System
WHEN DRIVING AT ANY SPEED VEHICLE WILL STALL AND CUT OFF WITHOUT PRIOR WARNING. VEHICLE HAS STALLED OUT IN THE MIDDLE OF AN INTERSECTION. CONSUMER HAS CONTACTED DEALER. DEALER NOTED THAT IGNITION WENT BAD WHICH CAUSED THE VEHICLE TO STALL . IGNITION WAS REPLACED ON A NUMBER OF OCCASIONS.*AK
NHTSA ODI #872737
Mileage unknown · Jul 26, 1999
Structure
THE ENTIRE FRAME HAS PREMATURLEY RUSTED, CAUSE UNKNOWN. PLEASE GIVE ANY FURTHER DETAILS. *AK
THE FORWARD OUTBOARD PEDESTAL OF THE SEAT TRACK OF DRIVER'S SEAT MAY BE SUSCEPTIBLE TO FATIGUE FRACTURE.
Consequence & remedy
Consequence: THIS COULD RESULT IN A LIMITED DEGREE OF ROCKING MOTIONOF THE DRIVERS SEAT ASSEMBLY UPON ACCELERATION OR DECELERATION, WHICH COULDCAUSE AN ACCIDENT.
Remedy: INSTALL A REINFORCEMENT ON ALL MODELS AND A NEW SEAT TRACK AS NECESSARY
SPRING LOCK FUEL LINE COUPLING MAY NOT BE PROPERLY ENGAGED.
Consequence & remedy
Consequence: COUPLING COULD DISENGAGE DUE TO FUEL PRESSURE,VIBRATION, AND ENGINE MOVEMENTS; THIS WOULD CAUSE LOSS OF FUEL WHICH, INPRESENCE OF AN IGNITION SOURCE, CREATES A FIRE RISK.
Remedy: INSTALL RETAINER CLIPS OVER THE COUPLINGS TO PREVENT COUPLING SEPARATION AND FUEL LEAKAGE.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
7
EA88038 · Rear Safety Belt Fit
Opened Aug 29, 1988 · Closed May 11, 1990
Status: closed (inferred from source dates) · Seat Belts:rear/other
===
DP88007 · Rear Seat Belt Compliance
Opened Jan 11, 1988 · Closed Aug 24, 1988
Status: closed (inferred from source dates) · Seat Belts:rear/other
REAR SEAT BELT COMPLIANCE
EA87023 · Seat Tracks
Opened Sep 24, 1987 · Closed Nov 16, 1989
Status: closed (inferred from source dates) · Seats
SUMMARY: A FRACTURED FRONT SEAT TRACK RECEIVED FROM AN ESCORT OWNER SHOWSTHAT METAL FATIGUE OCCURRED WHICH COULD CAUSE PARTIAL MOVEMENT OF THE SEAT.ANOTHER OWNER SENT PICTURES SHOWING FRACTURE AT THE SAME LOCATION. TENOF THE EIGHTEEN ODI COMPLAINTS HAVE BEEN RECEIVED IN THE PAST FOUR MONTHS.MANUFACTURER INFORMATION: FORD MADE TWO SIGNIFICANT MODIFICATIONS TO THESEAT TRACK; ONE INCORPORATED A DOUBLE LATCH SYSTEM, LOCKING BOTH THE IN-BOARD AND OUTBOARD TRACK ASSEMBLIES, AND THE OTHER ADDED WEB DEPTH IN THEFRONT AND REAR OF THE SEAT TRACK.FORD PROVIDED A TOTAL OF 1,741 WARRANTY CLAIMS CONCERNING SEAT TRACKFAILURE ON THE SUBJECT VEHICLES.THEY BELIEVE THAT FRACTURE OF THE SEAT TRACK CAUSES A LIMITED ROCKINGMOTION AND IS NOT A SAFETY PROBLEM.PROPOSED ACTION: IR TO FORD SENT 10/9/87.TEST REQUEST SENT TO ETF10/21/87.
PE87028 · Stalling
Opened May 1, 1987 · Closed Jan 21, 1988
Status: closed (inferred from source dates) · Electrical System
NO SAFETY DEFECT TREND HAS BEEN DETECTED.===
PE87026 · Seat Track Failure
Opened Apr 28, 1987 · Closed Sep 24, 1987
Status: closed (inferred from source dates) · Seats
SUMMARY: A FRACTURED FRONT SEAT TRACK RECEIVED FROM AN ESCORT OWNER SHOWSTHAT METAL FATIGUE OCCURRED WHICH COULD CAUSE PARTIAL MOVEMENT OF THE SEAT.ANOTHER OWNER SENT PICTURES SHOWING FRACTURE AT THE SAME LOCATION. TENOF THE EIGHTEEN ODI COMPLAINTS HAVE BEEN RECEIVED IN THE PAST FOUR MONTHS.MANUFACTURER INFORMATION: FORD MADE TWO SIGNIFICANT MODIFICATIONS TO THESEAT TRACK; ONE INCORPORATED A DOUBLE LATCH SYSTEM, LOCKING BOTH THE IN-BOARD AND OUTBOARD TRACK ASSEMBLIES, AND THE OTHER ADDED WEB DEPTH IN THEFRONT AND REAR OF THE SEAT TRACK.FORD PROVIDED A TOTAL OF 1,741 WARRANTY CLAIMS CONCERNING SEAT TRACKFAILURE ON THE SUBJECT VEHICLES.THEY BELIEVE THAT FRACTURE OF THE SEAT TRACK CAUSES A LIMITED ROCKINGMOTION AND IS NOT A SAFETY PROBLEM.PROPOSED ACTION: CLOSE THIS PE, OPEN AN EA, AND SEND ANOTHER IR TO FORD.===
EA87005 · Fires
Opened Dec 1, 1986 · Closed Oct 31, 1989
Status: closed (inferred from source dates) · Engine And Engine Cooling
SUMMARY OF INFORMATION FROM MANUFACTURER:THE ALLEGED FIRES RESULT FROMA VARIETY OF CAUSES.FIRE RATE REMAINS ABOUT THE SAME DESPITE MAJORCHANGES WITH 85-1/2 MODELS.IT BELIEVES THAT THE FIRE RATE IS LESS THANINDUSTRY AVERAGE.MFGR REQUEST COPIES OF SPECIFIC FIRE REPORTS FOR TRENDANALYSIS.ANALYSIS:SEVERAL AREAS OF FIRE ORIGIN ARE MENTIONED.ENGINE FIRESALLEGEDLY CAUSED BY LEAKAGE OF FLAMMABLE FLUIDS (OIL, GAS, TRANS FLUID).CATALYTIC CONVERTERS FREQUENTLY CITED AS OVERHEATING.CERTAIN MODELSARE REPORTED AT A GREATER FREQUENCY.EXP TURBO REPORTED MOST OFTEN ON APER UNIT BASIS.STATUS: IR SENT 2/19/88. AWAITING RESPONSE.===
EA86010 · Seatback Failure
Opened Mar 26, 1986 · Closed Jul 28, 1989
Status: closed (inferred from source dates) · Seats
SUMMARY OF INFORMATION FROM MANUFACTURER:FORD BELIEVES THAT THE AL-LEGED DEFECT ONLY OCCURS IN A SMALL NUMBER OF THE SUBJECT VEHICLES ANDRECALLED ABOUT 195,732 1984 TEMPO/TOPAZ VEHICLES IN JUNE 1986.ANALYSIS: VEHICLES POTENTIALLY INVOLVED INCLUDE TEMPO/TOPAZ, ESCORT/LYNX/EXP, MUSTANG/CAPRI, LTD/MARQUIS, AND THUNDERBIRD/COUGAR.FORD SOLD ABOUT 110,000 REPLACEMENT MIO BOLTS, MAINLY FOR 1983 AND 1984MODELS. LOW CLAMPING FORCE APPEARS TO BE A LARGE PART OF THE PROBLEM.FORD INCREASED THE TORQUE REQUIREMENTS AND REQUIRED THE USE OF A MANUALTORQUE TOOL IN MARCH AND SEPTEMBER 1985 PRODUCTION CHANGES. 1987 MODELSWILL BE PRODUCED WITH A LONGER M10 BOLT AND A NUT TO INCREASE AND MAIN-TAIN CLAMPING FORCE. BOLTS WERE FORMERLY SELF TAPPING. REPORTS LISTEDABOVE SPECIFICALLY STATE THAT THE BOLT BROKE. NONE REFER SIMPLY TOSEAT BACK COLLAPSE ALONE.STATUS:FORD REPLY TO ODI IR DATED 2/2/87.FORD RECALLED 195,7321984 TEMPO/TOPAZ VEHICLES IN JUNE 1986 (86V-082). ANALYZING REPONSE,MONITORING CANADIAN PROGRESS. RESPONSE TO 4/6/87 LETTER TO FORDRECEIVED 7/15/87. WILL PROBABLY CLOSE AFTER CANADA COMPLETES THEIRACTIONS.===