What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 3 of 30 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Electrical System. Review the 10 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 8 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 5 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports6 fire reports1 injury reports

What owners actually said

30 reports
94,000 miles · Jul 1, 2008
Fuel System, Gasoline

NHTSA CAMPAIGN ID# 91V146000 REFERS TO A SAFETY RECALL FOR A FAULTY DUAL FUEL TANK SELECTOR VALVE IN FORD ECONOLINE VANS EQUIPPED WITH DUAL FUEL TANKS BUILT BETWEEN 1989 AND 1991 AND OTHER SIMILAR MODELS . I HAVE CONTACTED FORD TO INVESTIGATE , BUT THERE ARE NO RECORDS THAT CONFIRM OR DISAFFIRM MY VEHICLE'S INCLUSION IN THIS REC…

Read full complaint

NHTSA CAMPAIGN ID# 91V146000 REFERS TO A SAFETY RECALL FOR A FAULTY DUAL FUEL TANK SELECTOR VALVE IN FORD ECONOLINE VANS EQUIPPED WITH DUAL FUEL TANKS BUILT BETWEEN 1989 AND 1991 AND OTHER SIMILAR MODELS . I HAVE CONTACTED FORD TO INVESTIGATE , BUT THERE ARE NO RECORDS THAT CONFIRM OR DISAFFIRM MY VEHICLE'S INCLUSION IN THIS RECALL. BASICALLY, I DON'T KNOW IF MY VAN WAS AFFECTED BY THIS RECALL AND IF ANY RECALL SERVICES WERE PERFORMED. I AM EXPERIENCING A FAULT IN THE DUAL FUEL TANK SYSTEM. IT SEEMS THAT THE FUEL SELECTOR VALVE WILL NOT SWITCH TO THE MAIN TANK, AND WHEN FILLED, THE MAIN TANK WILL FLOW PAST THE FILLER CAP AND CAUSES A FUEL LEAKAGE, WHICH CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. I CONTACTED A LOCAL FORD DEALER WHO ADVISED ME THAT NO RECALL SERVICE CAN BE PERFORMED TO REMEDY THIS PROBLEM BECAUSE MY VIN# DOES NOT REGISTER IN THE FORD RECALL DATABASE. AGAIN, FORD CANNOT CONFIRM OR DISAFFIRM ANY RECALL SERVICES PERFORMED ON MY VEHICLE. I AM NOT THE ORIGINAL OWNER OF THIS VEHICLE SO I DO NOT HAVE ANY SERVICE RECORDS PRIOR TO 2005. IN AN ATTEMPT TO CORRECT THIS CONCERN, I HAVE ALREADY REPLACED THE SECONDARY FUEL PUMP, AS ADVISED BY MY LOCAL MECHANIC. I HAVE ALSO OVERHAULED BOTH FUEL TANKS TO CHECK FOR CLOGGING, OR ANY FOREIGN MATERIALS, AND I HAVE REPLACED SEVERAL SEALS AND MISC. HARDWARE IN THE FUEL SYSTEM. THIS CONCERN HAS BEEN A PROBLEM SINCE I PURCHASED THE VEHICLE IN 2005. I AM ONLY ABLE TO OPERATE MY VEHICLE ON THE AUXILLARY (REAR) FUEL TANK WITH A 13 GALLON CAPACITY. WHEN THE SELECTOR SWITCH IS ON THE FRONT TANK, THE VEHICLE WILL EVENTUALLY STALL AS IF IT IS OUT OF FUEL. WHEN THE FUEL SELECTOR SWITCH IS SET TO THE REAR TANK, I AM ABLE TO OPERATE THE VEHICLE NORMALLY WITH THE EXCEPTION OF THE LIMITED RANGE DUE TO THE SMALL AUXILLARY FUEL TANK. *TR

NHTSA ODI #10232970

138,000 miles · Apr 25, 2008
Fuel System, Gasoline

VAN DIED,TOWED TO MECHANICS SHOP,WAS TOLD SWITCH VALVE BETWEEN TANKS WAS PROBLEM, LOOKED ON NHTSA WEBSITE ABOUT RECALLS. FORD VAN 89 E-150 WITH DUEL GAS TANKS. FORD SAFETY RECALL NUMBER IS 91S39 WENT TO FORD WEB SITE,CALLED THEM ON PHONE, CUSTOMER SERVICE AND LOCAL DEALERSHIP. BOTH SAID THERE WAS NO RECALL ON MY VAN. *TR

NHTSA ODI #10225733

61,000 miles · Jul 10, 2003
Tires

WHILE DRIVING, THE TIRE EXPERIENCED TREAD SEPARATION AND DAMAGED THE FRONT FENDER. *AK THE VALVE STEM WAS ALSO REPLACED. *PH *JB

NHTSA ODI #10024474

Mileage unknown · Oct 27, 2000
Electrical System

IGNITION MODULE HAS BEEN GIVING US PROBLEMS SINCE PURCHASED-1993- ONE TIME THE MODULE FAILED AND ANOTHER TIME IT WAS REPLACED, STILL THE PROBLEM PERSISTS. *AK

NHTSA ODI #735288

Mileage unknown · Oct 18, 2000
Electrical System

BEGAN HAVING SERIOUS PROBLEM WITH STALLING APPROX. 2 MOS AGO , STALLED WHILE AT HIGHWAY SPEEDS AND WHILE CROSSING INTERSECTIONS , ENDANGERING THE SAFETY OF MY FAMILY , WHICH CONSISTS OF MYSELF ,MY WIFE , AND OUR FOUR SMALL CHILDREN. THIS PROBLEM HAS OCCURED 7 TIMES. I HAVE REPAIRED IT TWICE. RECENTLY I TOOK IT TO THE LOCAL FO…

Read full complaint

BEGAN HAVING SERIOUS PROBLEM WITH STALLING APPROX. 2 MOS AGO , STALLED WHILE AT HIGHWAY SPEEDS AND WHILE CROSSING INTERSECTIONS , ENDANGERING THE SAFETY OF MY FAMILY , WHICH CONSISTS OF MYSELF ,MY WIFE , AND OUR FOUR SMALL CHILDREN. THIS PROBLEM HAS OCCURED 7 TIMES. I HAVE REPAIRED IT TWICE. RECENTLY I TOOK IT TO THE LOCAL FORD DEALERSHIP. AND AT FIRST THEY DENIED AND PROBLEM AND THE RECENT RECALL IN CALIFORNIA. IHAVE DONE A CONSIDERABLE AMOUNT OF RESEARCH REGARDING THIS PROBLEM INCLUDING MEETING WITH A REGIONAL FORD DISTRICT SERVICE MANAGER. PLEASE , PLEASE HELP ME...

NHTSA ODI #734638

Mileage unknown · Aug 27, 2000
Electrical System

THE AIR CONDITIONING BLOWER MOTOR SWITCH WAS MELTED I REPLACED IT AND IT MELTED AFTER 4000 MILES. I WENT TO A SALVAGE YARD AND THEY WERE ALL MELTED IN THE HI POSITION. WHEN ON HI THE WIRING GET SO HOT YOU CANNOT HOLD THE WIRES

NHTSA ODI #729257

Mileage unknown · Jun 11, 1999
Electrical SystemFire

ALTENATEOR HARNESS PLUG CONNECTOR SUDDENLY SHORT CIRCUTED, AND CAUSED VEHICLE TO CATCHON FIRE. DEALER HAS NOT BEEN CONTACTED. *AK

NHTSA ODI #839489

Mileage unknown · May 6, 1999
Electrical SystemFireInjury

FIRE STARTED ON DRIVERS SIDE NEAR STEERING WHEEL AND DASHBOARD.NM

NHTSA ODI #545870

Mileage unknown · Jul 7, 1998
Fuel System, Gasoline

VEHICLE HAS AUXILIARY FUEL TANK. WHEN FIRST TANK IS FILLED WITH GAS IT CAUSES SPILLAGE OF SECOND TANK. CAUSE UNKNOWN. *AK

NHTSA ODI #825116

Mileage unknown · Jan 21, 1998
Engine And Engine Cooling

ENGINE STALLS.

NHTSA ODI #528527

Official recalls

2

91V146000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices

Sep 4, 1991

THE DUAL FUEL TANK SELECTOR VALVE MAY MALFUNCTION AND CAUSE AN OVERFILL CONDITION IN ONE OF THE FUEL TANKS, RESULTING IN AN OVERFLOW OF FUEL PAST THE FILLER CAP.

Consequence & remedy

Consequence: THE OVERFLOW OF FUEL PAST THE FILLER CAP CAUSES A FUELLEAKAGE, WHICH CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION.

Remedy: REPLACE THE DUAL FUEL TANK SELECTOR VALVE.

90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)

Jun 1, 1990

UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.

Consequence & remedy

Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.

Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

3

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available